Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate ▷ View online
IEC 60950 (3rd)
- Page 3 of 6 -
www.nemko.com
Report No. 158002
2.6.101
Add this sub-clause:
Earthing of CLASS 0I EQUIPMENT
Plugs with a lead wire for earthing shall not be used for
equipment having a rated voltage exceeding 150V.
For plugs with a lead wire for earthing, the lead wire
shall not be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with an
earthing terminal or lead wire for earthing in the
external where easily visible.
Earthing of CLASS 0I EQUIPMENT
Plugs with a lead wire for earthing shall not be used for
equipment having a rated voltage exceeding 150V.
For plugs with a lead wire for earthing, the lead wire
shall not be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with an
earthing terminal or lead wire for earthing in the
external where easily visible.
Class III equipment
N/A
3.2.5
Delete 1) in Table 3B.
Considered. N/A
4.2.8
Add the following informative remark after the last
sentence.
Remark - IEC 61965 is also applicable instead of IEC
60065.
sentence.
Remark - IEC 61965 is also applicable instead of IEC
60065.
No CRTs in equipment.
N/A
4.5.1
Addition:
Add the following to suffix 5) as specified in
“Conditions applicable to Table 4A, Parts 1 and 2”.
“Conditions applicable to Table 4A, Parts 1 and 2”.
With regard to Table 4A, insulating materials
complying with Japanese requirements (refer to
Japanese differences for the current IEC 60335-1 (3rd
Edition) in CB Bulletin 101B) are also acceptable.
complying with Japanese requirements (refer to
Japanese differences for the current IEC 60335-1 (3rd
Edition) in CB Bulletin 101B) are also acceptable.
Add a suffix 7) in “Conditions applicable to Table 4A,
Parts 1 and 2”.
Parts 1 and 2”.
In the right column of Table 4A, Part 1, add suffix 7) to
“50” (K), corresponding to “- without T – marking” in
the left column so as to become “50 7)”.
“50” (K), corresponding to “- without T – marking” in
the left column so as to become “50 7)”.
Add 7) to Table 4A, Part 2 as follows.
7) This value shall apply only to wiring or cords
complying with relevant IEC standards. Others shall
comply with Japanese requirements (refer to Japanese
differences for the current IEC 60335-1 (3rd Edition) in
CB Bulletin 101B).
complying with relevant IEC standards. Others shall
comply with Japanese requirements (refer to Japanese
differences for the current IEC 60335-1 (3rd Edition) in
CB Bulletin 101B).
Considered. P
4.7.3.2
Add the following in 7
th
paragraph of this Sub-Clause.
-
for thin materials, e.g., flexible printed boards, etc.,
used inside equipment, be of FLAMMABILITY CLASS
VTM-2 or better.
VTM-2 or better.
Comply with the
requirement.
requirement.
P
IEC 60950 (3rd)
- Page 4 of 6 -
www.nemko.com
Report No. 158002
5.1.6
Replacement:
Replace Table 5A.
Replace Table 5A.
Class III equipment
N/A
5.3.8.2
Replacement:
Replace 3rd Item as follows.
Replace 3rd Item as follows.
- BASIC INSULATION between the PRIMARY
CIRCUIT and accessible conductive parts of
CLASS I or 0I EQUIPMENT;
CIRCUIT and accessible conductive parts of
CLASS I or 0I EQUIPMENT;
Class III equipment
N/A
Annex A
Add this Sub-Clause:
Flammability tests for classifying materials VTM
Flammability tests for classifying materials VTM
Thin sheet materials shall comply with ISO 9773.
Comply with the requirement.
P
Annex G
Add the following new note below Table G.1:
2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
Not used.
N/A
Annex P
Add “IEC 61965:2000, Mechanical Safety for
Cathode Ray Tubes”.
Cathode Ray Tubes”.
CRT(s) not used in the equip
ment.
ment.
N/A
Annex U
Replace the second paragraph by:
This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm.
This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm.
See main test report.
N/A
U.2.1
Replace the text of this Sub-Clause by:
The test sample is prepared according to IEC
60851-5:1996, 4.4.1 (for a twisted pair). The
sample is then subjected to the test of 5.2.2 of
this standard, with a test voltage not less than
twice the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
The test sample is prepared according to IEC
60851-5:1996, 4.4.1 (for a twisted pair). The
sample is then subjected to the test of 5.2.2 of
this standard, with a test voltage not less than
twice the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 3000 V,
or;
SUPPLEMENTARY INSULATION, 3000 V,
or;
- for REINFORCED INSULATION, 6000 V.
TIW not used.
N/A
IEC 60950 (3rd)
- Page 5 of 6 -
www.nemko.com
Report No. 158002
U.2.2
Replace this Sub-Clause by:
Test 8 of IEC 60851-3:1996, 5.1.1, using the
mandrel diameters of table U.1. The test sample
is then examined in accordance with IEC 60851-
3:1996, 5.1.1.4, followed by the test of 5.2.2 of
this standard except applying the test voltage
between the wire and the mandrel. A test voltage
shall be the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
Test 8 of IEC 60851-3:1996, 5.1.1, using the
mandrel diameters of table U.1. The test sample
is then examined in accordance with IEC 60851-
3:1996, 5.1.1.4, followed by the test of 5.2.2 of
this standard except applying the test voltage
between the wire and the mandrel. A test voltage
shall be the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 1500 V,
or;
SUPPLEMENTARY INSULATION, 1500 V,
or;
- for REINFORCED INSULATION, 3000 V.
TIW not used.
N/A
Table U.1 Table U.1 - Mandrel diameter
Nominal Conductor
diameter
mm
Mandrel diameter
mm ± 0,2 mm
0,05 – 0,34
0.35 – 0,49
0,50 – 0,74
0,75 – 2,49
2,50 – 5,00
0.35 – 0,49
0,50 – 0,74
0,75 – 2,49
2,50 – 5,00
4,0
6,0
8,0
6,0
8,0
10,0
4 times of the diameter of
conductor
1)
1)
in compliance with IEC 60317-43.
The tension to be applied to the wire during
winding on the mandrel is calculated from the
wire diameter to be equivalent to 118 Mpa ± 10 %
(118 N/mm
winding on the mandrel is calculated from the
wire diameter to be equivalent to 118 Mpa ± 10 %
(118 N/mm
2
± 10 %).
Table U.1
Replacement:
Mandrel diameter
Mandrel diameter
The tension to be applied to the wire during
winding on the mandrel is calculated from the
wire diameter to be equivalent to 118 Mpa ±
10 % (118 N/mm2 ± 10 %).
TIW not used.
N/A
IEC 60950 (3rd)
- Page 6 of 6 -
www.nemko.com
Report No. 158002
U.2.3
Replacement:
Replace the first paragraph with the following.
Test 9 of IEC 60851-6:1996, followed by the
electric strength test of 5.2.2 of this standard
except applying the test voltage between the
wire and the mandrel. A test voltage shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard.
However, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
Test 9 of IEC 60851-6:1996, followed by the
electric strength test of 5.2.2 of this standard
except applying the test voltage between the
wire and the mandrel. A test voltage shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard.
However, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
TIW not used.
N/A
U.2.4
Replace the third paragraph of this Sub-Clause,
which is describing the test voltage, by:
The test voltage shall not be less than the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be
as follows:
which is describing the test voltage, by:
The test voltage shall not be less than the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be
as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 1500 V,
or;
SUPPLEMENTARY INSULATION, 1500 V,
or;
-
for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
TIW not used.
N/A
U.3.1
Replace the text of this Sub-Clause by:
The test voltage for ROUTINE TESTING shall be
the appropriate voltage in table 5B (see 5.2.2) of
this standard. However, the minimum values
shall be as follows:
The test voltage for ROUTINE TESTING shall be
the appropriate voltage in table 5B (see 5.2.2) of
this standard. However, the minimum values
shall be as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 1500 V
r.m.s. or 2100 V peak, or;
SUPPLEMENTARY INSULATION, 1500 V
r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V
r.m.s. or 4200 V peak.
TIW not used.
N/A
U.3.2
Replace the text of this Sub-Clause by:
Twisted pair samples shall be tested in
accordance with IEC 60851-5:1996, 4.4.1. The
minimum breakdown voltage shall not be less
than twice the appropriate voltage in table 5B
(see 5.2.2) of this standard. However, the
minimum values shall be as follows:
Twisted pair samples shall be tested in
accordance with IEC 60851-5:1996, 4.4.1. The
minimum breakdown voltage shall not be less
than twice the appropriate voltage in table 5B
(see 5.2.2) of this standard. However, the
minimum values shall be as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 3000 V
r.m.s. or 4200 V peak, or;
SUPPLEMENTARY INSULATION, 3000 V
r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V
r.m.s. or 8400 V peak.
TIW not used.
N/A