PROGRAMMING MANUAL
CODE: 00ZXEA110VPME
ELECTRONIC
CASH REGISTER
MODEL 
XE-A110
MODEL 
XE-A130
SRV KEY : Not necessary
(For "V" version)
1.  MASTER RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
2.  PROGRAMMINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
3.  PRINTING OF PROGRAM REPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
4.  X/FLASH, Z/PGM REPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
CONTENTS
SHARP CORPORATION
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
1. MASTER RESET
Master reset: Clears all the memories and initializes each preset pa-
rameter.
Master reset should be performed by using the following procedure.
1. Turn off the power (Power OFF). (See Note 1.)
2. Disconnect the ECR memory buck up battery.
3. Turn the mode switch any position of Power-off.
4. Turn on the power (Power ON). (See Note 2.)
When the master reset is completed, the buzzer sounds intermittently
three times.
5. Attach the memory buck up battery to the ECR.
The master reset can also be accomplished in the following case.
(See Note3.)
Note 1) Power OFF: Means stopping the AC power supply to the
machine.
(Specifically, unplugging the machine.)
Note 2) Power ON: Means supplying the AC power to the machine.
(Specifically, plugging in the machine.)
Note 3) In case power failure occurs when the machine has no bat-
tery attached to it, the master reset operation is automatically
performed after the power has been restored.
(This is because if power failure occurs with no battery at-
tached to the machine, all the memory is lost and the ma-
chine does not work properly after power recovery;
this requires the master reset operation.)
2. PROGRAMMINGS
Mode
Programming jobs can be executed at Z-mode.
Programming report can be printed at Z-mode.
Programming
The programming key operation sequence differs from one function
to another and is therefore described for each programming opera-
tion.
Programming result is not printed at the end of each programming
job.
When the first programming job is executed, the ECR displays "P".
And when the SUBTOTAL key is pressed after some programming
jobs are done, programming report is issued and the displayed "P"
disappears.
Price programming for dept. key
YYYYY: Unit price (Max. 5 digits)
MRS = 0.00
Dept. function programming
A:
Sign
A
+
0
1
B:
SICS/Normal
B
Normal
0
SICS
1
*
SICS = Single item cash sale
C:
Taxable 2
B
No
0
Yes
1
D:
Taxable 1
D
No
0
Yes
1
E:
Limitation
E
Limitation
 7
*
Limitation = 0 
 7 (HALO)   0 = Open price registalation inhibit.
MRS = XE-A110
DEPT. 1 
 4:
+Sign/Normal/Taxable 1/7 Digits = 00017
MRS = XE-A130
DEPT. 1 
 5:
+Sign/Normal/Taxable 1/7 Digits = 00017
Price & modify programming for 
$
 key (Only XE-A130)
XXXXX : Unit price (Max 5 digits)
MRS = 0.00
$
 function programming (Only XE-A130)
A, B, C, D: Not used (Fixed at "0000")
E:
Limitation
E
Limitation
 7
Limitation : 0 
 7 (HALO) 0: Open price registration inhibit.
MRS = 7 digits
Programming rate for %key
XXXX : 0.01% 
 99.99%
MRS = 0.00%
YYYYY
0
DPT. n
#/ST
#/ST
ABCDE
0
DPT. n
/TM or
XXXXX
0
#/ST
ABCDE
0
#/ST
XXXX
0
%
#/ST
– 1 –
Programming for %key
A:
Sign
A
+
0
1
MRS = –Sign
VAT rate & Lower TAX limitation programming
A:
Tax 1 programming
= 1
Tax 2 programming
= 2
% tax rate:
0.0000% to 99.9999%
Lower tax limitation: 0 to 99999
MRS = 0.0000%, 0
Consecutive number setting
XXXX : Consecutive no. = 0000 to 9999 (4 digits)
MRS = 0000
Date setting
XXYYZZ : Date  (Year-month-day/Day-month-year/Month-day-year)
the date format depends on job No.1.
MRS = 010100 (month-day-year)
Time setting
XX : Hour (00 to 11 or 00 to 23)
YY : Minute (00 to 59)
The hour format depends on job No. 1.
MRS = 0000
Others programming
A:
Date format
A
Month/Day/Year
0
Day/Month/Year
1
Year/Month/Day
2
B:
Time format
B
12H
0
24H
1
C:
TAB
C
0
.   
0
0.0 
 1
0.00 2
0.000
3
D:
Receipt No. reset at Z report issue
D
No
0
Yes
1
E:
Amount tender compulsory
E
No
0
Yes
1
F:
Sub total compulsory
F
No
0
Yes
1
G:
Limitation (HALO) of Miscellaneous key
G
 8 digit
 8
H:
Fractional treatment
H
Rounding
0
Raising
1
Discarding
2
MRS = 11200080
A
0
%
#/ST
/TM or
9
A
XXXXXX
DECLARATION OF TAX
% TAX RATE
TL/AT/NS
#/ST
/TM or
XXXX
#/ST
/TM or
XXYYZZ
#/ST
XXYY
#/ST
1
ABCDEFGH
0
#/ST
#/ST
– 2 –
Print format programming
A:
TAX system
A
Manual VAT
0
Auto VAT
1
B:
Print in REG mode
B
Print
0
Not print
1
C:
Print format
C
Journal
0
Receipt
1
D:
Date print
D
Print
0
Not print
1
E:
Time print
E
Print
0
Not print
1
F:
Consecutive No. print
F
Print
0
Not print
1
G:
Taxable subtotal
G
Print
0
Not print
1
H:
Merchandise subtotal by "#/ST" key
H
Print
0
Not print
1
MRS = 00000001
Secret code programming
MRS = 0000
3. PRINTING OF PROGRAM
REPORTS
Key entry
Report name
 #/ST 
General programmed data report
1
 XE-A110
2
 XE-A130
2
ABCDEFG
0
#/ST
#/ST
XXXX
TL/AT/NS
SECRET CODE
/TM or
     1006 1
    10.75
     0104 2
    -3.00
     1107 3
    13.00
     0006 4
  -123.56
   -10.00  %
      #9999
 00000000#1
 00000000#2
   6.0000 1TX
   4.0000 2TX
   12-31-95
 0001#23-59
SICS/NORMAL, TAX STATUS, HALO, DEPT. CODE
+/-SIGN. UNIT PRICE
+/- SIGN, RATE for %
SECRET CODE
OTHERS PROGRAMMING
PRINT PROGRAMMING
RATE for TAX1
12345678910111213
      1007
   1#10.75
      0104
   2#-3.00
 .
 .
     1106
 5#-123.56
         7
     -1.25 -
 
    -10.00%
 
     #9999
 
  00000000*1
  00000000*2
 
    6.0000TX1
    4.0000TX2
 
  31-12-95
0001#23-59
SICS/NORMAL, TAX STATUS, HALO
+/-SIGN. UNIT PRICE
HALO for (-)
UNIT PRICE for (-)
+ /- SIGN, RATE for %
SECRET CODE
OTHERS SELECT
PRINT SELECT
RATE for TAX1
43210987654321
– 3 –
Page of 5
Display

Sharp XE-A130 Service Manual ▷ Download

  • DOWNLOAD Sharp XE-A130 Service Manual ↓ Size: 44.06 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XE-A130 in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XE-A130 ECR. Information contained in Sharp XE-A130 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.