Harman Kardon SB 35 Sabre (serv.man2) EMC - CB Certificate ▷ View online
Page 9 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
b) marking on loudspeaker grille, IEC 60417-5036
N/A
5.4
Instructions for use
English
(Version in other language will
be provided when submitted
for national approval)
(Version in other language will
be provided when submitted
for national approval)
Pass
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
Stated in user manual.
Pass
b) Hazardous live terminals, instructions for wiring
No live terminals.
N/A
c) Instructions for replacing lithium battery
No lithium battery.
N/A
d) Class I earth connection warning
N/A
e) Instructions for multimedia system connection
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
Stated in user manual.
Pass
h) Warning: protective film on CRT face
No CRT provided.
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Stated in user manual.
Pass
c) Instructions for permanently connected equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6 Hazardous
radiation
-
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
................................................................................... :
LED indicator is used, below
class 1.
class 1.
Pass
Emission limits under fault conditions ..................... :
Pass
7
Heating under normal operating conditions
-
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
See appended table 7.1.
Pass
7.1.1
Temperature rise of accessible parts
See appended table 7.1.
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table 7.1.
Pass
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
See appended table 7.1.
Pass
7.1.4
Temperature rise of windings
See appended table 7.1.
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table 7.1.
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
N/A
Page 10 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8
Constructional requirements with regard to the protection against electric
shock
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
shock
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
-
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Not done without a tool.
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used.
Pass
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
See CL. 8.6
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
See appended table 13.
Pass
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Switching Transformer T541
comply with CL. 14.3.
comply with CL. 14.3.
Pass
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
See appended table 14.
CY502, CY503, CY504 and
CY505.
CY502, CY503, CY504 and
CY505.
Pass
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced
insulation
> 0,4 mm (mm) ....................:
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
N/A
Page 11 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
See appended table 10.3.
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
PVC, 2 x 0.4mm
Pass
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
PVC, 2 x 0.4mm
Pass
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Secondary: Single insulated,
dressed away from primary.
dressed away from primary.
N/A
8.11
Detaching of wires
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Pass
Vibration test carried out .........................................: See CL. 12.1.2. N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
No hot parts or sharp edges
around wires.
around wires.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
Mains plug.
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
Page 12 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9
Electric shock hazard under normal operating conditions
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
-
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
Between L&N and output
terminals: 375Vpeak.
terminals: 375Vpeak.
Pass
b) Touch current measured from terminal devices
using the network in annex D .................................:
using the network in annex D .................................:
U1: 0.854V peak,
U2: 0.217V peak.
U2: 0.217V peak.
Pass
c) Discharge not exceeding 45 μC
<45 μC. Pass
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
No hazardous live parts are
accessible.
accessible.
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers
Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No top ventilation.
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ..................:
of the mains plug; voltage (V) after 2 s ..................:
8.3Vdc (Standby)
16.7Vdc (Standby, with R502
opened)
Rating of R502, R503, R504,
R505: 1MΩ
16.7Vdc (Standby, with R502
opened)
Rating of R502, R503, R504,
R505: 1MΩ
Pass
If C is not greater than 0,1 μF no test needed
0.33μF. N/A
9.1.7
Resistance to external forces
Pass
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
b) Test hook of fig. 4 for 10 s (20 N)
Pass
c) 30 mm diameter test tool for 5 s (100 or 250 N)
N/A
9.2
No hazard after removing a cover by hand
N/A
10 Insulation
requirements
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35SUB: See below
-
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N/A
10.2 Humidity
treatment 48 h or 120 h ...........................: 40
°C, 95%, 120h.
Pass
Click on the first or last page to see other SB 35 Sabre (serv.man2) service manuals if exist.