IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
16
External flexible cords
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
-
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................:
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................:
See appended table 14.
Pass
Non-detachable cords for Class I have green/yellow
core for protective earth
core for protective earth
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
0.75mm² × 2
Pass
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
bending and mechanical stress (3.2 of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
Appliance inlet used.
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible
cord
cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
live conductors become taut before earth conductor
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
fitted with detachable cord set with appliance inlet to
IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
Page 22 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
17
Electrical connections and mechanical fixings
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
-
17.1
Torque test to table 20
Pass
- screws into metal: 5 times
N/A
- screws into non-metallic material: 10 times
1.2Nm
Pass
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N/A
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
by a screw whose length is 10 times its diameter
>10mm / >10mm
(Clearance/Creepage)
(Clearance/Creepage)
Pass
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a current
> 0,2 A
other than ceramic for connections carrying a current
> 0,2 A
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
2N applied.
Pass
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
-
18.1
Picture tube separately approved to IEC 61965 ....: No picture tube.
N/A
Picture tube separately approved to 18.2 ..............:
N/A
18.2
Non-intrinsically protected tubes tested to 18.2
N/A
19
Stability and mechanical hazards
-
Mass of the equipment exceeding 7 kg .................: < 7 kg.
N/A
Apparatus intended to be fastened in place –
suitable instructions ................................................:
suitable instructions ................................................:
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability
to point of least stability
N/A
19.4
Edges or corners not hazardous
Edges and corners are
smoothed and rounded.
smoothed and rounded.
Pass
Page 23 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
N/A
19.6
Wall or ceiling mountings adequate
For SABRE SB35CNTR:
The mounting means remain
secure during the test.
The mounting means remain
secure during the test.
Pass
20
Resistance to fire
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
-
20.1
Electrical components and mechanical parts
-
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
Components mounted on
PCB.
PCB.
Pass
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
See CL. 20.1.4.
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
No such wiring.
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
See appended table 14
All PCB: V-0.
All PCB: V-0.
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
See appended table 14
All PCB: V-0.
All PCB: V-0.
Pass
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
See appended table 14.
T541, LIF502 and plastic
enclosure.
T541, LIF502 and plastic
enclosure.
Pass
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1 Potential
ignition
sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
There is no part exceeding 4
kV.
kV.
N/A
Page 24 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
1 mm in width and with openings for wires
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
-
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
-
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
-
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions