Page 17 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 N/A 
14.5 
Protective devices  
 
Pass 
 
Protective devices used within their ratings  
Primary fuse: F501 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
See appended table 13. 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved  
 
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
See appended table 14. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...: 
F501: T3.15AL250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ................: 
 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
Not replaced without a tool. 
Pass 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
 N/A 
14.6 
Switches  
No switch. 
N/A 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
 N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
Page 18 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Switch controlling < 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 N/A 
14.9 Motors 
 
N/A 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 N/A 
14.10 
Batteries 
The remote control provided 
with non-rechargeable lithium 
battery but the following test 
not required. 
Pass 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 Pass 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
See appended table 14. 
Pass 
Page 19 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
Pass 
 
b) Comply with IEC 60747-5-5: 2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8  
N/A 
14.12 
Surge suppression varistors  
RV501 
Pass 
 
Comply with IEC 61051-2  
See appended table 14. 
Across the line, protected by 
fuse-link, F501. 
Pass 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 N/A 
 
15 Terminals 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
See appended table 14. 
Pass 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
 N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
 N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 Pass 
 
No risk of insertion in mains socket-outlets  
 
Pass 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
 N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
 N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II apparatus. 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A  ...................:   N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
For SABRE SB35CNTR:  
Not directly connected to the 
mains. 
For SABRE SB35SUB: 
Detachable power supply 
cord. 
N/A 
Page 20 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board   
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 N/A 
 
Wire secured by additional means to the  
conductor   
 N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
 N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
 N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16   
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 N/A 
15.4 
Devices forming a part of the mains plug  
 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 N/A 