Harman Kardon SB 35 Sabre (serv.man2) EMC - CB Certificate ▷ View online
Test Report issued under the responsibility of:
TEST REPORT
IEC 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Number. ..............................:
ACSCBAV13005
Date of issue ...................................:
July 29, 2013
Total number of pages...................:
41 pages
Applicant’s name............................:
TCL TECHNOLY ELECTRONICS (HUIZHOU) CO., LTD.
Address ...........................................:
Section 19, Zhongkai High-tech Development Zone, Huizhou
City, Guang Dong Province, China, 516006
City, Guang Dong Province, China, 516006
Test specification:
Standard ..........................................:
IEC 60065: 2001 (Seventh Edition) + A1: 2005 + A2: 2010
Test procedure................................:
CB Scheme
Non-standard test method.............:
N/A
Test Report Form No......................:
IEC60065K
Test Report Form(s) Originator.....:
Intertek Semko AB
Master TRF ......................................:
Dated 2010-10
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .....................:
Soundbar Speaker System
Trade Mark ......................................:
harman/kardon
Manufacturer...................................:
Harman International Industries, Inc.
8500 Balboa Blvd, Northridge, CA 91329, UNITED STATES
8500 Balboa Blvd, Northridge, CA 91329, UNITED STATES
Model/Type reference ....................:
SABRE SB35, SABRE SB35CNTR, SABRE SB35SUB
Ratings ............................................:
24V
, 2.7A (SABRE SB35CNTR)
100-240V~, 50/60Hz, 100W (SABRE SB35SUB)
Page 2 of 41
Report No.: ACSCBAV13005
TRF No. IEC60065K
Testing procedure and testing location:
CB
Testing
Laboratory:
Audix Technology (Shenzhen) Co., Ltd.
Testing location/ address ........................: No. 6, Ke Feng Road, Block 52, Shenzhen Science &
Industry Park, Nantou, Shenzhen, Guangdong, China
Tested by (name + signature) ....... :
Michael Han
Approved by (name + signature).. :
Carolyn Kang
Associated CB Laboratory:
Testing location/ address ........................:
Tested by (name + signature) ....... :
Approved by (name + signature).. :
Testing procedure: TMP
Testing location/ address ........................:
Tested by (name + signature) ....... :
Approved by (name + signature).. :
Testing procedure: WMT
Testing location/ address ........................:
Tested by (name + signature) ....... :
Witnessed by (name + signature). :
Approved by (name + signature).. :
Testing procedure: SMT
Testing location/ address ........................:
Tested by (name + signature) ....... :
Approved by (name + signature).. :
Supervised by (name + signature) :
Testing procedure: RMT
Testing location/ address ........................:
Tested by (name + signature) ....... :
Approved by (name + signature).. :
Supervised by (name + signature) :
Page 3 of 41
Report No.: ACSCBAV13005
TRF No. IEC60065K
List of Attachments (including a total number of pages in each attachment):
-
Attachment 1: European Group Differences (15 pages)
-
Attachment 2: National Deviations: Australia/New Zealand, Korea, MALAYSIA, Japan (15 pages)
-
Attachment 3: Manufacturer’s Declaration (2 pages)
-
Attachment 4: Photographs (12 pages)
-
Attachment 5: Diagrams (4 pages)
-
Attachment 6: Schematics + PWB Layout (5 pages)
Summary of testing:
1) The sample tested complies with the requirements of the test specification.
2) Soundbar (SABRE SB35CNTR) and Subwoofer (SABRE SB35SUB) were evaluated respectively.
3) As for Power Transformer (T541) in power supply board of Subwoofer (SABRE SB35SUB), multi
factories will produce them as alternative use. Since it was same to each other on construction and
electrical characteristics, the difference of factory did not affect safety aspects.
Unless otherwise specified, all tests were conducted on the following transformer as representative.
T541: Huizhou Sunshine Electronics Co., Ltd. / BCK-AL140
electrical characteristics, the difference of factory did not affect safety aspects.
Unless otherwise specified, all tests were conducted on the following transformer as representative.
T541: Huizhou Sunshine Electronics Co., Ltd. / BCK-AL140
4) Following symbols and abbreviations are used in this test report.
S/C= Short-Circuit
O/C= Open-Circuit
NH= No Hazard Occurred
NFR= No Further Results existed
NB= No breakdown NCD= No component damaged
PCB= Printed Circuit Board
* = Determined by the method specified in Note f to Table 3.
PCB= Printed Circuit Board
* = Determined by the method specified in Note f to Table 3.
Tests performed (name of test and test clause):
Marking durability test (5)
Input test (5.1)
Heating test (7.1)
Touch current (9.1.1)
Withdrawal of mains plug test (9.1.6)
Humidity test (10.2)
Insulation resistance and dielectric strength test
(10.3)
Fault condition test (11.1)
Heating test under fault condition (11.2)
Impact test (12.1.3)
Stress relief test (12.1.5)
Determination of operating voltage (13.2)
Screw securement test (17.1)
Stability test (19.1)
Wall or ceiling mounting means test (19.6)
Marking durability test (5)
Input test (5.1)
Heating test (7.1)
Touch current (9.1.1)
Withdrawal of mains plug test (9.1.6)
Humidity test (10.2)
Insulation resistance and dielectric strength test
(10.3)
Fault condition test (11.1)
Heating test under fault condition (11.2)
Impact test (12.1.3)
Stress relief test (12.1.5)
Determination of operating voltage (13.2)
Screw securement test (17.1)
Stability test (19.1)
Wall or ceiling mounting means test (19.6)
Testing location: see page 2 (Testing procedure
and testing location)
and testing location)
Summary of compliance with National Differences
List of countries addressed: EU, AU, NZ, KR, MY, JP
List of countries addressed: EU, AU, NZ, KR, MY, JP
SG (no national differences in CB-Bulletin)
The product fulfils the requirements of _ IEC 60065: 2001 (Seventh Edition) + A1: 2005 + A2: 2010/
EN 60065: 2002 (Seventh Edition) + A1: 2006 + A11: 2008 + A2: 2010 + A12: 2011_
Page 4 of 41
Report No.: ACSCBAV13005
TRF No. IEC60065K
Copy of marking plate:
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
authorized by the respective NCBs that own these marks.
Soundbar (SABRE SB35CNTR)