Harman Kardon SB 35 Sabre (serv.man2) EMC - CB Certificate ▷ View online
Page 13 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
See appended table 10.3.
Pass
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table 10.3.
Pass
11 Fault
conditions
-
11.1
No shock hazard under fault condition
For SABRE SB35SUB:
U1: 0.887V peak,
U2: 0.246V peak.
U1: 0.887V peak,
U2: 0.246V peak.
Pass
11.2
Heating under fault condition
Pass
Flames extinguish within 10 seconds
No flames occurred.
N/A
No hazard from softening solder
Pass
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
See appended table 11.2.
Pass
11.2.2
Temperature rise of accessible parts
See appended table 11.2.
Pass
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
See appended table 11.2.
Pass
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
See appended table 11.2.
Pass
11.2.5
Temperature rise of windings
See appended table 11.2.
Pass
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
Pass
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................:
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................:
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
See appended table 11.2.
Pass
Page 14 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
12 Mechanical
strength
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35SUB: See below
-
12.1.1
Bump test where mass >7 kg
<7 kg.
N/A
12.1.2
Vibration test
Table top with plastic
enclosure.
enclosure.
N/A
12.1.3
Impact hammer test
Pass
Steel ball test
2J applied to enclosure, and
then no damaged.
then no damaged.
Pass
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg Not portable.
N/A
12.1.5
Thermoplastic enclosures stress relief test
No risk of shrinkage or
distortion on enclosure.
distortion on enclosure.
Pass
12.2
Fixing of knobs, push buttons, keys and levers
N/A
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
-
13.1
Clearances in accordance with 13.3
See appended table 13.
Pass
Creepage distances in accordance with 13.4
See appended table 13.
Pass
13.2
Determination of working voltage
See appended table 13.
Pass
13.3
Clearances
See appended table 13.
Pass
13.3.1 General
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9.............:
with table 8 and, where applicable, table 9.............:
See appended table 13.
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4 Measurement
of
transient voltages
N/A
13.4
Creepage distances
See appended table 13.
Pass
Creepage distances greater than table 11 minimum
values
values
See appended table 13.
Pass
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
Page 15 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
For SABRE SB35CNTR: Not directly connected to the mains.
For SABRE SB35SUB: See below
For SABRE SB35SUB: See below
-
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
No such resistors.
N/A
Resistors
separately approved ...............................:
N/A
14.2
Capacitors and RC units
See appended table 14.
Pass
Capacitors separately approved :
Pass
14.2.1
Y capacitors tested to IEC 60384-14:2005 .............:
CY502, CY503, CY504,
CY505: Y1
CY505: Y1
Pass
14.2.2
X capacitors tested to IEC 60384-14:2005 .............:
CX501: X2
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 .......................:
connected to the mains: tests for X2 .......................:
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ..................:
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ..................:
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................:
metal ........................................................................:
N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
See CL. 20.1.4.
Pass
Page 16 of 41
Report No.: ACSCBAV13005
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
manufacturer's name and type ...............................:
T541:
Type: BCK-AL140
Type: BCK-AL140
Mfg. Trademark:
-Alt. use-
Type: BCK-03EC35
Mfg. Trademark:
-Alt. use-
Type: BCK-PQ3230-L-5666
Mfg. Trademark:
Pass
Transformers and inductors separately approved .:
N/A
14.3.2
General
T541: Isolating transformer.
Pass
Insulation material complies with clause 20.1.4
See appended table 14.
Pass
14.3.3
Constructional requirements
See appended table 14.
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See appended table 13.
Pass
14.3.3.2
Transformers meet the constructional requirements See appended table 13.
Pass
14.3.4
Separation between windings
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
See appended table 13.
Pass
Coil formers and partition walls > 0,4 mm
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
Pass
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See appended table 13.
T541.
T541.
Pass
Coil formers and partition walls > 0,4 mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
Click on the first or last page to see other SB 35 Sabre (serv.man2) service manuals if exist.