DOWNLOAD Harman Kardon SB 35 Sabre (serv.man2) Service Manual ↓ Size: 2.77 MB | Pages: 94 in PDF or view online for FREE

Model
SB 35 Sabre (serv.man2)
Pages
94
Size
2.77 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-35-sabre-sm2.pdf
Date

Harman Kardon SB 35 Sabre (serv.man2) EMC - CB Certificate ▷ View online

Page 13 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
See appended table 10.3. 
Pass 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
See appended table 10.3. 
Pass 
 
11 Fault 
conditions 
11.1 
No shock hazard under fault condition  
For SABRE SB35SUB: 
U1: 0.887V peak, 
U2: 0.246V peak. 
Pass 
11.2 
Heating under fault condition  
 
Pass 
 
Flames extinguish within 10 seconds  
No flames occurred. 
N/A 
 
No hazard from softening solder  
 
Pass 
 
Soldered terminations not used  as protective 
mechanism  
 Pass 
11.2.1 
Measurement of temperature rises  
See appended table 11.2. 
Pass 
11.2.2 
Temperature rise of accessible parts  
See appended table 11.2. 
Pass 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
See appended table 11.2. 
Pass 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
See appended table 11.2. 
Pass 
11.2.5 
Temperature rise of windings  
See appended table 11.2. 
Pass 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
 N/A 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 Pass 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm² ................:
 N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 N/A 
 
Class I protective earthing maintained  
 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
See appended table 11.2. 
Pass 
 
Page 14 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
12 Mechanical 
strength 
For SABRE SB35CNTR: Not directly connected to the mains. 
For SABRE SB35SUB: See below
 
12.1.1 
Bump test where mass >7 kg  
<7 kg. 
N/A 
12.1.2 
Vibration test  
Table top with plastic 
enclosure. 
N/A 
12.1.3 
Impact hammer test  
 
Pass 
 
Steel ball test  
2J applied to enclosure, and 
then no damaged. 
Pass 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg  Not portable. 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test  
No risk of shrinkage or 
distortion on enclosure. 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers  
 
N/A 
12.3 
Remote controls with hazardous live parts  
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
 
N/A 
12.6 
Telescoping or rod antennas construction  
 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 
N/A 
 
13 
Clearances and creepage distances 
For SABRE SB35CNTR: Not directly connected to the mains. 
For SABRE SB35SUB: See below
 
13.1 
Clearances in accordance with 13.3  
See appended table 13. 
Pass 
 
Creepage distances in accordance with 13.4  
See appended table 13. 
Pass 
13.2 
Determination of working voltage  
See appended table 13. 
Pass 
13.3 
Clearances  
See appended table 13. 
Pass 
13.3.1 General 
 
 
Pass 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9.............: 
See appended table 13. 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
 N/A 
13.3.4 Measurement 
of 
transient voltages  
 
N/A 
13.4 
Creepage distances  
See appended table 13. 
Pass 
 
Creepage distances greater than table 11 minimum 
values  
See appended table 13. 
Pass 
13.5 
Printed boards  
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 N/A 
Page 15 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 N/A 
 
14 Components 
For SABRE SB35CNTR: Not directly connected to the mains. 
For SABRE SB35SUB: See below
 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such resistors. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
No such resistors. 
N/A 
 Resistors 
separately approved ...............................: 
 
N/A 
14.2 
Capacitors and RC units  
See appended table 14. 
Pass 
 
Capacitors separately approved  : 
 
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14:2005 .............:
CY502, CY503, CY504, 
CY505: Y1 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14:2005 .............:
CX501: X2 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 .......................:
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better ..................:
 N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................: 
 N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ........................................................................: 
 N/A 
14.3 
Inductors and windings  
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
See CL. 20.1.4. 
Pass 
Page 16 of 41 
Report No.: ACSCBAV13005 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
T541:  
Type: BCK-AL140 
Mfg. Trademark: 
 
 
-Alt. use- 
Type: BCK-03EC35 
Mfg. Trademark: 
 
 
-Alt. use- 
Type: BCK-PQ3230-L-5666 
Mfg. Trademark: 
 
Pass 
 
Transformers and inductors separately approved .: 
 
N/A 
14.3.2 
General  
T541: Isolating transformer. 
Pass 
 
Insulation material complies with clause 20.1.4  
See appended table 14. 
Pass 
14.3.3 
Constructional requirements  
See appended table 14. 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
See appended table 13. 
Pass 
14.3.3.2 
Transformers meet the constructional requirements  See appended table 13. 
Pass 
14.3.4 
Separation between windings 
 
Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)..............................: 
See appended table 13. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
 N/A 
14.3.4.3 
Separating transformers with at least basic insulation  
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 Pass 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
See appended table 13. 
T541. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 N/A 
14.4 
High voltage components  
 
N/A 
Page of 94
Display

Click on the first or last page to see other SB 35 Sabre (serv.man2) service manuals if exist.