                           Report No.: SH10011244-002 
Appended tables: 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
dT (K) 
monitored point: 
264 
90 
Permitted dT (K) 
PCB near U503 
22.0
 
25.2
 
85 
EC502 (electrolytic capacitor) 
32.4
 
45.9
 
70 (105-35) 
Winding of T502 
20.3
 
22.1
 
75 
Bobbin of T502 
35.2
 
52.9
 
-- 
PCB near T502 
28.7
 
32.5
 
85 
CY504 (Y1 capacitor)  
26.4
 
32.2
 
50 (85-35) 
Winding of T503 
31.2
 
29.1
 
75 
Bobbin of T503 
36.5
 
31.5
 
-- 
PCB near T503 
32.5
 
27.6
 
85 
CY503 (Y1 capacitor)  
31.2
 
27.5
 
50 (85-35) 
PCB near D515 
33.3
 
27.5
 
85 
EC518 (electrolytic capacitor) 
33.1
 
27.1
 
70 (105-35) 
PCB of amplifier board 
33.1
 
32.3
 
85 
PCB of main board 
31.6
 
30.7
 
85 
Enclosure (metallic)  
14.8
 
12.8
 
40  
Enclosure (non-metallic) 
6.4
 
6.1
 
60 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation 
100 
Between parts separated by double or reinforced insulation 
9.8 
Between parts of T502 separated by basic or supplementary 
insulation 
100 2 
Between parts of T503 separated by basic or supplementary 
insulation 
100 2 
  
 
 
 Page 25 of 69 
                           Report No.: SH10011244-002 
Appended tables: 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120Vp 
No 
Between parts separated by basic or supplementary insulation 
2120Vp 
No 
Between parts separated by double or reinforced insulation 
4240Vp 
No 
Between parts of T502 separated by basic or supplementary 
insulation 
2542Vp No 
Between parts of T503 separated by basic or supplementary 
insulation 
2586Vp No 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
         
  Model/type of power supply  .................................: -- 
— 
 
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240 
 
         
  Ambient temperature (
o
C) ...................................... : 24 
— 
 
No. 
Component 
No. 
Fault 
Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test
1.  
U502: 
secondary     
  
SC 264 
10 
min.
F501
0.063 
P=1.7W. No high 
temperature, no hazard.  
Pass 
2.   
R531          SC 
264 
10 min.
F501
0.062 
P=1.5W. No high 
temperature, no hazard.  
Pass 
3.   
D510      
SC 
264 
10 min.
F501
0.124 
P=10.5W max. No high 
temperature, no hazard.  
Pass 
4.   
D512      
SC 
264 
10 min.
F501
0.160 
P=13.4W max. No high 
temperature, no hazard.  
Pass 
5.   
D513          SC 
264 
10 min.
F501
0.142 
P=12.0W. No high 
temperature, no hazard.  
Pass 
6.   
D514      
SC 
264 
10 min.
F501
0.162 
P=13.2W. No high 
temperature, no hazard.  
Pass 
7.   
EC506   
SC 
264 
10 min.
F501
0.188 
P=17.5W max. No high 
temperature, no hazard.  
Pass 
8.   
EC511  
SC 
264 
10 min.
F501
0.162 
P=16.8W. D512 damaged, 
no high temperature, no 
hazard.  
Pass 
9.   
EC514  
SC 
264 
15 min.
F501
0.241→
0.125 
P=24.6W max. P=13.6W 
min, 2 minutes, P=11.5. No 
extreme high temperature, no 
hazard. 
Pass 
10.  
EC516 
SC 
264  10 min.
F501
0.156 
P=13.8W max. No high 
temperature, no hazard.  
Pass 
11.  
U502:  
primary       
SC 264 
10 
min.
F501
0.059 
P=1.0W. No high 
temperature, no hazard.  
Pass 
12.   
EC501         SC 
264 
10 min.
F501
0.061 
P=1.6W. No high 
temperature, no hazard.  
Pass 
 
 Page 26 of 69 
                           Report No.: SH10011244-002 
Appended tables: 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
No. 
Component 
No. 
Fault 
Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test
13.   
D503        
SC 
264 
10 min.
F501
0.061 
P=1.6W. No high 
temperature, no hazard.  
Pass 
14.  
U504: 
secondary     
  
SC 264 
10 
min.
F501
0.162 
P=17.2W. No high 
temperature, no hazard.  
Pass 
15.  
U504:  
primary       
SC 264 
50 
min.
F501
0.36 
P=45W, as normal. No high 
temperature, no hazard.  
Pass 
16.  
U515: 
secondary     
  
SC 264 
50 
min.
F501
0.36 
P=45W, as normal. No high 
temperature, no hazard.  
Pass 
17.   
R543        
SC 
264 
10 min.
F501
0.153 
P=16.4W. No high 
temperature, no hazard.  
Pass 
18.  
U505: 
secondary     
  
SC 264 
10 
min.
F501
0.154 
P=16.5W. No high 
temperature, no hazard.  
Pass 
19.  
U515:  
primary       
SC 264 
10 
min.
F501
0.153 
P=16.4W. No high 
temperature, no hazard.  
Pass 
20.  
U505:  
primary       
SC 264 
10 
min.
F501
0.154 
P=16.4W. No high 
temperature, no hazard.  
Pass 
21.   
EC505       
SC 
264 
10 min.
F501
0.171 
P=18.9W. No high 
temperature, no hazard.  
Pass 
22.   
D506        
SC 
264 
10 min.
F501
0.169 
P=18.7W. No high 
temperature, no hazard.  
Pass 
23.   
EC503         SC 
264 
10 min.
F501
0.174 
P=19.6W. No high 
temperature, no hazard.  
Pass 
24.  
D505 
SC 
264 
10 min.
F501
0.152 
P=16.3W. R522 damaged, 
no high temperature, no 
hazard.  
Pass 
25.   
D508      
SC 
264 
20 min.
F501
0.851→
0.195 
P=116.2W max. 20s, P=21.5. 
Q509, R570, U506, R571, 
Q510, R576 damaged. No 
extreme high temperature, no 
hazard. 
Pass 
26.   
D516      
SC 
264 
10 min.
F501
0.178 
P=19.8W. No high 
temperature, no hazard.  
Pass 
27.   
EC519     
SC 
264 
10 min.
F501
0.178 
P=20.1W. No high 
temperature, no hazard.  
Pass 
28.  
D504 
SC 
264 
1 H 
F501
0.355 
P=46.4W. No extreme high 
temperature, no hazard. 
Pass 
29.   
R575    
SC 
264 
1 H 
F501
0.36 
P=45.6W, as normal. No high 
temperature, no hazard.  
Pass 
30.  
C502 
SC 
264 
1s 
F501
11→0
P=0W, F501 opened 
immediately, no high 
temperature, no hazard.  
Pass 
31.  
BD501 
SC 
264 
1s 
F501
11→0
P=0W, F501 opened 
immediately, no high 
temperature, no hazard. 
Pass 
 
 Page 27 of 69 
                           Report No.: SH10011244-002 
Appended tables: 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
No. 
Component 
No. 
Fault 
Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test
32.  
EC502 
SC 
264 
1s 
F501
11→0
P=0W, F501 opened 
immediately, no high 
temperature, no hazard. 
Pass 
33.   Q509: D-S 
SC 
264 
1s 
F501
11→0
P=0W, R588, R589 
damaged, F501 opened 
immediately, no high 
temperature, no hazard.  
Pass 
34.  
Maximum volume on 
all loudspeakers 
264 1 
H F501
1.05→
0.624→
0.447→
0.341 
P=160W, 5s, P=86.7W, 
3min, P=59.0W, 3min, 
P=43.3W. No extreme high 
temperature, no hazard. 
Pass 
35.  
Adjust volume on all 
loudspeakers, and 
circuit no protected 
264 4 
H F501
0.470 
P=63.2W. No extreme high 
temperature, no hazard.  
Pass 
36.  
Ventilating holes 
blocked 
264 4 
H F501
0.36 
P=45.6W, as normal. No high 
temperature, no hazard.  
Pass 
(SC=short circuit, OC=open circuit, MUL=most unfavourable load) 
 
 
13.3 & 13.4  TABLE: clearance and creepage distance measurements  
Pass 
 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
(V) 
required cl
(mm) 
cl 
(mm) 
required dcr 
(mm) 
dcr 
(mm) 
L to N (BI)  
338 
240 
2.0 
4.0 
2.5 
4.0 
Primary circuit to accessible 
parts / enclosure (RI) 
338 240  4.0  5.0  5.0  5.6 
Primary circuit to accessible 
parts / enclosure (RI) 
536 254  4.3  5.0  5.2  7.4 
Primary circuit to accessible 
parts / enclosure (RI) 
560 275  4.4  6.8  5.8  6.8 
Transformer T502:                
primary to secondary (RI) 
536 254  4.3  9.5  5.2  9.5 
Transformer T502:                
primary to core (BI) 
536 254  2.2  5.5  2.6  5.5 
Transformer T502:                  
core to secondary (SI) 
536 254  2.2  4.5  2.6  4.5 
Transformer T503:                
primary to secondary (RI) 
560 275  4.4  8.0  5.8  8.0 
Transformer T503:                
primary to core (BI) 
560 275  2.2  4.0  2.9  4.0 
Transformer T503:                  
core to secondary (SI) 
560 275  2.2  4.0  2.9  4.0 
 
 
Page of 70