          Page 16 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
Optocouplers comply with Cl. 8 
Internal DTI >0.40mm min. 
Pass 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
int./ext. Cl. &Cr.  4mm min. / 
≥6.0mm min. 
Pass 
14.12 
Surge suppression varistors 
VDE approved 
Pass 
 
Comply with IEC 61051-2 
 
Pass 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 Pass 
 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Approved appliance inlet 
provided.                                
Pass 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
Pass 
 
No risk of insertion in mains socket-outlets 
 
Pass 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
         
 N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II 
N/A 
 Deleted 
(A1) 
 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A ................... :  
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 Pass 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
The EUT is not a permanently 
connected apparatus 
N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
N/A 
 
          Page 17 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
Not soldered to conductors of a printed circuit 
board 
No. Pass 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 Pass 
 
Wire secured by additional means to the conductor Mating lock connector 
Pass 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
         
 N/A 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
         
 N/A 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Mating lock connector, both the 
conductor and insulation are 
crimped. 
Pass 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
         
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
         
 N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
         
 N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
         
 N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
         
 N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
         
 Pass 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
Approved appliance inlet is 
provided 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
         
 N/A 
15.4 
Devices forming a part of the mains plug 
No such device 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 N/A 
 
 
 
          Page 18 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................ :
PVC  
Pass 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Approved appliance inlet is 
provided 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
 Pass 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
No such kind of flexible cords 
used. 
N/A 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
         
 N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
         
 N/A 
16.5 
Adequate strain relief on external flexible cords 
Approved appliance inlet is 
provided 
N/A 
 
Not possible to push cord back into equipment 
         
 N/A 
 
Strain relief device unlikely to damage flexible cord
         
 N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
         
 N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
         
 Pass 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
         
 N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
         
 N/A 
 
17 ELECTRICAL 
CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
 
Pass 
 
- screws into metal: 5 times 
Cover fixed 
Pass 
 
          Page 19 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
- screws into non-metallic material: 10 times 
Cover fixed 
Pass 
17.2 
Correct introduction into female threads in non-
metallic material 
 N/A 
17.3 
Cover fixing screws: captive 
Non-captive. 
N/A 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 
Pass 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
 Pass 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
 
Pass 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No such device. 
N/A 
17.8 
Fixing devices for detachable legs or stands 
provided 
No such device. 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
 
Pass 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
 
Picture tube separately approved to IEC 61965: 
No picture tube.  
N/A 
 
Picture tube separately approved to 18.1 ...............  
N/A 
8.1 
Picture tubes > 16 cm intrinsically protected 
         
 N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
         
 N/A 
 
Protective film as part of implosion protection: 
edges covered by enclosure (A1) 
 N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
         
 N/A 
18.2.1 
Samples subject to ageing: 6 
         
 N/A 
18.2.2 
Samples subject to implosion test: 6 
         
 N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
         
 N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
         
 N/A 
 
 
Page of 70