DOWNLOAD Harman Kardon HS 2X0 (serv.man2) Service Manual ↓ Size: 6.3 MB | Pages: 70 in PDF or view online for FREE

Model
HS 2X0 (serv.man2)
Pages
70
Size
6.3 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-2x0-sm2.pdf
Date

Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate ▷ View online

 
          Page 8 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 
1000Vac or 1500Vdc 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
U1=10.3Vp  
U2=0.30Vp 
Pass 
 
Discharge not exceeding 45 μC 
Less than 45
μC 
Pass 
 
Energy of discharge not exceeding 350 mJ 
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe 
 Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 Pass 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
No enter. 
Pass 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
Test probe did not become 
hazardous live parts after test. 
Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
Test probe did not become 
hazardous live parts after test. 
Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No such pre-set control used. 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
Less than the limit. 
Discharging resistor 
R501=R502=560 kΩ max 
Pass 
 
If C is not greater than 0,1 μF no test needed 
 N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 
Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
No damage of enclosure and 
no hazardous live parts are 
accessible. 
Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
No hazardous live parts are 
accessible. 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N 
Pass 
9.2 
No hazard after removing a cover by hand 
Tools required. 
N/A 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
 Pass 
10.2 Humidity 
treatment 48 h or 120 h ........................... : 48h, 30℃, 95%R.H. 
Pass 
 
          Page 9 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
Pass 
 
Insulation Resistance and dielectric strength 
across BASIC or SUPPLEMENTARY insulation 
(Class 1) 
Class II 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
(see appended table) 
Pass 
 
 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
Single fault did not cause 
excessive voltage in output 
circuits. 
Pass 
11.2 
Heating under fault condition 
 
Pass 
 
No hazard from softening solder 
No softening of solder point 
and becoming fluid 
Pass 
11.2.1 
Measurement of temperature rises 
(see appended table) 
Pass 
11.2.2 
Temperature rise of accessible parts 
(see appended table) 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
(see appended table) 
Pass 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
         
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
         
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
         
 N/A 
 
Class I protective earthing maintained 
Class II 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
(see appended table) 
Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
Mass weight : 3.53 kg. 
Pass 
12.1.2 Vibration 
test 
 
N/A 
 
          Page 10 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
12.1.3 
Impact hammer test 
0.5J, no hazards after the test 
Pass 
 
Steel ball test 
2J, no hazards after the test 
Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 N/A 
12.1.5 
Thermoplastic enclosures strain relief test 
70°C / 7 hours 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
Pass 
12.3 
Remote controls with hazardous live parts 
No remote control device with 
hazardous live parts 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawer is provided 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial socket is 
provided as isolation 
N/A 
12.6 
Telescoping or rod antennas construction 
No such device 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
T502: 254Vrms, 536Vp 
T503: 275Vrms, 560Vp 
Pass 
13.3 Clearances 
 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
(see appended table) 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 Creepage 
distances 
 
Pass 
 
Creepage distances greater than table 11 minima  (see appended table) 
Pass  
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
          Page 11 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
Optocoupler are approved 
components.                      
Pass 
 
 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R558 Pass 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved  .......................... : R558 approved by VDE
 
Pass 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY501, CY502, CY503, 
CY504 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: CX501, CX502, CX503 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such component 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Such capacitors with metal 
cased 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Such capacitors with metal 
cased 
N/A 
 
Shielded by a barrier to V-0 or metal  ..................... :  N/A 
14.3 
Inductors and windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type .............................. :
Power transformer T502, T503 
Line filter LF501, LF502  
(See appended table14) 
Pass 
 
Transformers and inductors separately approved . : No 
N/A 
14.3.2 General 
 
Pass 
Page of 70