Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate ▷ View online
Page 8 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000Vac or 1500Vdc
1000Vac or 1500Vdc
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1=10.3Vp
U2=0.30Vp
U2=0.30Vp
Pass
Discharge not exceeding 45 μC
Less than 45
μC
Pass
Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
Pass
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
No enter.
Pass
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No such pre-set control used.
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Less than the limit.
Discharging resistor
R501=R502=560 kΩ max
Discharging resistor
R501=R502=560 kΩ max
Pass
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
No damage of enclosure and
no hazardous live parts are
accessible.
no hazardous live parts are
accessible.
Pass
Test hook of fig. 4 for 10 s (20 N)
No hazardous live parts are
accessible.
accessible.
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N
Pass
9.2
No hazard after removing a cover by hand
Tools required.
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Pass
10.2 Humidity
treatment 48 h or 120 h ........................... : 48h, 30℃, 95%R.H.
Pass
Page 9 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
10.3
Insulation resistance and dielectric strength
(see appended table)
Pass
Insulation Resistance and dielectric strength
across BASIC or SUPPLEMENTARY insulation
(Class 1)
across BASIC or SUPPLEMENTARY insulation
(Class 1)
Class II
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table)
Pass
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
Single fault did not cause
excessive voltage in output
circuits.
excessive voltage in output
circuits.
Pass
11.2
Heating under fault condition
Pass
No hazard from softening solder
No softening of solder point
and becoming fluid
and becoming fluid
Pass
11.2.1
Measurement of temperature rises
(see appended table)
Pass
11.2.2
Temperature rise of accessible parts
(see appended table)
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
(see appended table)
Pass
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
Class II
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table)
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
Mass weight : 3.53 kg.
Pass
12.1.2 Vibration
test
N/A
Page 10 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
12.1.3
Impact hammer test
0.5J, no hazards after the test
Pass
Steel ball test
2J, no hazards after the test
Pass
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
N/A
12.1.5
Thermoplastic enclosures strain relief test
70°C / 7 hours
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
No remote control device with
hazardous live parts
hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawer is provided
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided as isolation
provided as isolation
N/A
12.6
Telescoping or rod antennas construction
No such device
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T502: 254Vrms, 536Vp
T503: 275Vrms, 560Vp
T503: 275Vrms, 560Vp
Pass
13.3 Clearances
Pass
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
(see appended table)
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.4 Creepage
distances
Pass
Creepage distances greater than table 11 minima (see appended table)
Pass
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Page 11 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Optocoupler are approved
components.
components.
Pass
14 COMPONENTS
14.1 Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R558 Pass
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
b) Resistors separately approved .......................... : R558 approved by VDE
Pass
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY501, CY502, CY503,
CY504
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: CX501, CX502, CX503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such component
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Such capacitors with metal
cased
cased
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Such capacitors with metal
cased
cased
N/A
Shielded by a barrier to V-0 or metal ..................... : N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer’s name and type .............................. :
manufacturer’s name and type .............................. :
Power transformer T502, T503
Line filter LF501, LF502
(See appended table14)
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
Click on the first or last page to see other HS 2X0 (serv.man2) service manuals if exist.