Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate ▷ View online

 
          Page 20 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 7 kg  ................. : No, mass weight : 3.53 kg. 
N/A 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
         
 N/A 
19.2 
100 N force applied vertically downwards 
         
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability (A1) 
         
 N/A 
19.4 
Edges or corners not hazardous 
The outer surface of the EUT 
is smoothed. No sharp edges 
and corners 
Pass 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension 
> 450 mm, pass the test of 19.5.1 
No such glass surfaces. 
N/A 
19.6 
Wall or ceiling mountings adequate 
No such function. 
N/A 
 
20 
RESISTANCE TO FIRE 
 
20.1 
Electrical components and mechanical parts 
Pass 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width (A1) 
 N/A 
 
b) Exemption for small components as defined in 
20.1 
Components are mounted on 
a PCB of V-0 
Pass 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
See components list 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
No voltage exceeds 4kV. 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
Rated: V-0 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
Rated: V-0 
Pass 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
See components list 
Pass 
 
          Page 21 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 N/A 
20.2 Fire 
enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
 
Z1 
Resistance to candle flame ignition (EN60065 A11:2008) 
 
 
A television set shall be so designed that the 
likelihood of ignition and the spread of fire caused 
by a candle flame is reduced. 
 N/A 
 
This requirement does not apply to the display 
screen of rear projection TV’s. 
 N/A 
 
Compliance is checked according to CLC/TS 
62441. 
 N/A 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
         
 N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
         
 N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
         
 N/A 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No connected to the 
telecommunication networks 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
         
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
         
 N/A 
 
          Page 22 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
         
 N/A 
 
Complies with IEC 62151 clause 6  
         
 N/A 
 
Complies with IEC 62151 clause 7  
         
 N/A 
 
Complies with IEC 62151 annex A, B and C 
         
 N/A 
 
 Page 23 of 69 
                           Report No.: SH10011244-002 
Appended tables: 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
5.1 
TABLE: rated current/power consumption 
Pass 
 
Model  
Input voltage 
(V) 
Rated 
current 
(mA) 
Measured 
current 
(mA) 
Rated 
power (W) 
Measured 
power (W) 
condition/status 
240  - 
401 300 45.1 
HS 2X0  
100  - 
702 300 43.2 
Normal DVD playing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.1 
TABLE: temperature rise measurements  
Pass 
 
Power consumption in the OFF/Stand-by 
0W/1.4W max. 
— 
 
Position of the functional switch (W) ...................... :
On 
— 
 
Room temperature t1 (°C)  ...................................:
25.0 
 
 
Room temperature t2 (°C)  ...................................:
25.0 
 
Operating conditions 
Normal DVD playing. Pink noise as audio input, 1/8 non-clipped power output to speaker, operates 4 hours 
until steady condition reached.  
Un (V) 
In (mA)  
Pn (W)  
Pout (V / mA) 
264 368 
45.8 
N.A. 
90 767 
43.4 
N.A. 
 
         
 
Loudspeaker impedance (Ω) ................................. : 6Ω X 2 
— 
         
 
Several loudspeaker systems 
2 channel speakers 
Pass 
         
 
Marking of loudspeaker terminals 
Printed on rear enclosure 
Pass 
 
dT (K) 
monitored point: 
264 
90 
Permitted dT (K) 
Power cord 
18.0
 
18.4
 
60  
Connector  
22.0
 
25.2
 
PCB near RZ503 
32.4
 
45.9
 
85 
CY502 (Y1 capacitor)  
20.3
 
22.1
 
50 (85-35) 
CX503 (X2 capacitor ) 
28.7
 
32.5
 
50 (85-35) 
Winding of LF501 
26.4
 
32.2
 
75 
PCB near BD501 
31.2
 
29.1
 
85 
PCB near Q509 
18.0
 
18.4
 
85 
Page of 70