Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. : No, mass weight : 3.53 kg.
N/A
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability (A1)
to point of least stability (A1)
N/A
19.4
Edges or corners not hazardous
The outer surface of the EUT
is smoothed. No sharp edges
and corners
is smoothed. No sharp edges
and corners
Pass
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No such glass surfaces.
N/A
19.6
Wall or ceiling mountings adequate
No such function.
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
Pass
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width (A1)
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width (A1)
N/A
b) Exemption for small components as defined in
20.1
20.1
Components are mounted on
a PCB of V-0
a PCB of V-0
Pass
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
See components list
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No voltage exceeds 4kV.
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
Rated: V-0
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Rated: V-0
Pass
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
See components list
Pass
Page 21 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Z1
Resistance to candle flame ignition (EN60065 A11:2008)
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
N/A
This requirement does not apply to the display
screen of rear projection TV’s.
screen of rear projection TV’s.
N/A
Compliance is checked according to CLC/TS
62441.
62441.
N/A
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No connected to the
telecommunication networks
telecommunication networks
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Page 22 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 23 of 69
Report No.: SH10011244-002
Appended tables:
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
5.1
TABLE: rated current/power consumption
Pass
Model
Input voltage
(V)
(V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
240 -
401 300 45.1
HS 2X0
100 -
702 300 43.2
Normal DVD playing
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
0W/1.4W max.
—
Position of the functional switch (W) ...................... :
On
—
Room temperature t1 (°C) ...................................:
25.0
Room temperature t2 (°C) ...................................:
25.0
Operating conditions
Normal DVD playing. Pink noise as audio input, 1/8 non-clipped power output to speaker, operates 4 hours
until steady condition reached.
until steady condition reached.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 368
45.8
N.A.
90 767
43.4
N.A.
Loudspeaker impedance (Ω) ................................. : 6Ω X 2
—
Several loudspeaker systems
2 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
dT (K)
monitored point:
264
90
Permitted dT (K)
Power cord
18.0
18.4
60
Connector
22.0
25.2
-
PCB near RZ503
32.4
45.9
85
CY502 (Y1 capacitor)
20.3
22.1
50 (85-35)
CX503 (X2 capacitor )
28.7
32.5
50 (85-35)
Winding of LF501
26.4
32.2
75
PCB near BD501
31.2
29.1
85
PCB near Q509
18.0
18.4
85