Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate ▷ View online

 
           Page 36 of 69                          Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
6.1 
C: Replace the entire subclause by:  
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under fault 
conditions.  
Compliance is checked by measurement under the 
following conditions:  
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, by 
any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made.  
NOTE Soldered joints and paint lockings are 
examples of adequate locking.  
The amount of ionizing radiation is regulated by 
European Council Directive 96/29/Euratom of 13 
May 1996. This directive requires that at any point 
10 cm from the outer surface of the apparatus, the 
dose-rate shall not exceed 1µSv/h (0,1 mR/h) 
taking account of the background level.  
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for 1 h, at the end of which the 
measurement is made. 
A picture is considered to be intelligible if the 
following conditions are met: - a scanning 
amplitude of at least 70 % of the usable screen 
width; - a minimum luminance of 50 cd/m² with 
locked blank raster provided by a test generator; - 
a horizontal resolution corresponding to at least 
1,5 MHz in the centre, with a similar vertical 
degradation; - not more than one flashover per 5 
min. 
Replaced   
N/A 
13.3.1 
C: Delete note 4. 
Deleted  
Pass 
14 
C: Delete note 4 and note 5. 
Deleted  
Pass 
15.1.1 
C: Delete note 1 and note 2. 
Deleted  
Pass 
15.2 
C: Delete note 2. 
Deleted  
Pass 
16.1 
C: Delete note 1. 
Deleted  
Pass 
16.2 
C: Delete the note. 
Deleted  
Pass 
20 
C: Delete note 2. 
Deleted  
Pass 
 
           Page 37 of 69                          Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
Annex B 
C: Replace note 1 by: In the CENELEC countries 
listed in IEC 62151, special national conditions 
apply. 
Replaced  
N/A 
Annex G 
C: Delete the note. 
Deleted  
N/A 
Annex J.2  C: Delete the notes of Table J.1 
Deleted  
N/A 
Annex N 
C: Add after the introduction: For ROUTINE TEST 
reference is made to EN 50333. 
Added  
N/A 
 
 
           Page 38 of 69                          Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
Biblio-
graphy 
C: Add the following standards:  
EN 50332-1:2000, Sound system equipment: 
Headphones and earphones associated with 
portable audio equipment − Maximum sound 
pressure level measurement methodology and 
limit considerations − Part 1: General method for 
“one package equipment”.   
prEN 50332-2 (under consideration), Sound 
system equipment: Headphones and earphones 
associated with portable audio equipment − 
Maximum sound pressure level measurement 
methodology and limit considerations − Part 2: 
Guidelines to associate sets with headphones 
coming from different manufacturers. 
C: Add the following notes for the standards 
indicated:  
IEC 60130           NOTE    Parts 9 and 17:1998 are 
harmonized as Ens (not modified).  
IEC 60169           NOTE    Partly harmonized in the 
EN 60169/HD 134 series (not modified).  
IEC 60173           NOTE    Harmonized as HD 27 
S1:1978 (not modified).  
IEC 60335-2-56   NOTE    Harmonized as EN 
60335-2-56:1997 (not modified).  
IEC 60335-2-82   NOTE    Harmonized as EN 
60335-2-82:2000 (not modified).  
IEC 60695           NOTE    Harmonized as EN 
60695 series (not modified).  
IEC 61040           NOTE    Harmonized as EN 
61040:1992 (not modified).  
IEC 61558-2-1     NOTE    Harmonized as EN 
61558-2-1:1997 (not modified).  
IEC 61558-2-4     NOTE    Harmonized as EN 
61558-2-4:1997 (not modified).  
IEC 61558-2-6     NOTE    Harmonized as EN 
61558-2-6:1997 (not modified). 
 N/A 
 
 
           Page 39 of 69                          Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
Annex ZA 
(normative) 
The following referenced documents are indispensable for the application of this 
document. For dated references, only the edition cited applies. For undated 
references, the latest edition of the referenced document (including any 
amendments) applies. 
NOTE When an international publication has been modified by common 
modifications, indicated by (mod), the relevant EN/HD applies. 
Publication Date Title EN/HD Date 
- - Audio, video and similar electronic apparatus - Routine electrical safety testing 
in production EN 50333 2001 
IEC 60027 Series Letter symbols to be used in electrical technology EN 60027 
Series 
IEC 60038 2002 IEC standard voltages - - 
IEC 60068-2-6 + corr. March 1995 1995 Environmental testing - Part 2: Tests - 
Test Fc: Vibration (sinusoidal) EN 60068-2-6 1995 
IEC 60068-2-32 1975 Environmental testing - Part 2: Tests - Test Ed: Free fall EN 
60068-2-32 
1) 
1993  
IEC 60068-2-75 1997 Environmental testing - Part 2: Tests - Test Eh: Hammer 
tests EN 60068-2-75 1997 
IEC 60068-2-78 2001 Environmental testing - Part 2: Tests - Test Cab: Damp 
heat, steady state EN 60068-2-78 2001 
IEC 60085 2004 Electrical insulation – Thermal evaluation EN 60085 2004 
IEC 60086-4 2000 Primary batteries - Part 4: Safety of lithium batteries EN 
60086-4 2000 
IEC 60112 2003 Method for the determination of the proof and the comparative 
tracking indices of solid insulating materials EN 60112 2003 
IEC 60127 Series Miniature fuses EN 60127 Series 
IEC 60167 1964 Methods of test for the determination of the insulation resistance 
of solid insulating materials HD 568 S1 1990 
IEC 60216 Series Electrical insulating materials - Thermal endurance properties 
EN 60216 Series 
IEC 60227 (mod) 
2) 
Series Polyvinyl chloride insulated cables of rated voltages up 
to and including 450/750 V - - 
IEC 60245 (mod) 
3) 
Series Rubber insulated cables – Rated voltages up to and 
including 450/750 V - - 
IEC 60249-2 Series Base materials for printed circuits - Part 2: Specifications 
EN 60249-2 Series 
IEC 60268-1 1985 Sound system equipment - Part 1: General HD 483.1 S2 
4) 
1989 
IEC 60317 Series Specifications for particular types of winding wires EN 60317 
Series 
IEC 60320 Series Appliance couplers for household and similar general purposes 
EN 60320 Series 
IEC 60335-1 (mod) A1:2001 A2:2004 + corr. August:2006 Household and similar 
electrical appliances - Safety - Part 1: General requirements EN 60335-1:2002 
A1: 2004 + corr. January: 2007 A2: 2006 + A11: 2004 + A12: 2006 
IEC 60384-1 (mod) 1999 Fixed capacitors for use in electronic equipment - 
Part 1: Generic specification EN 60384-1 2001 
IEC 60384-14 2005 Fixed capacitors for use in electronic equipment - Part 14: 
Sectional specification: Fixed capacitors for electromagnetic interference 
suppression and connection to the supply mains EN 60384-14 2005 
 
Pass 