Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate ▷ View online
page 8 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
Pass
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1<8.0Vp
U2<0.06Vp
U2<0.06Vp
Pass
Discharge not exceeding 45 µC <1µC Pass
Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
< 2 mm, no entering
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
< 5V
Pass
If C is not greater than 0,1 µF no test needed
> 0.2 µF
N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
Test hook of fig. 4 for 10 s (20 N)
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N Pass
9.2
No hazard after removing a cover by hand
Can not be removed by hand
N/A
10 INSULATION
REQUIREMENTS
Pass
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
(See appended table)
Pass
10.2 Humidity
treatment 48 h or 120 h ........................... : 120h, 40℃, 93%R.H.
Pass
10.3
Insulation resistance and dielectric strength
(See appended table)
Pass
page 9 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
11 FAULT
CONDITIONS
Pass
11.1
No shock hazard under fault condition
Pass
11.2
Heating under fault condition
(See appended table)
Pass
No hazard from softening solder
Pass
11.2.1
Measurement of temperature rises
Pass
11.2.2
Temperature rise of accessible parts
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(See appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
Pass
12.1.1
Bump test where mass >7 kg
4.6kg
N/A
12.1.2 Vibration
test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
Pass
12.1.3
Impact hammer test
0.5J Pass
Steel ball test
2J Pass
12.1.4
Drop test for portable apparatus where mass < 7 kg Pass
12.1.5
Thermoplastic enclosures strain relief test
70
o
C, 7h
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
N/A
page 10 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
12.4
Drawers (pull test 50 N, 10 s)
Pass
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
Pass
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
TR1: pin3- 13, 340Vrms,
1.0kVp
1.0kVp
TR2: pin1-8,9,10, 280Vrms,
420Vp
420Vp
Pass
13.3 Clearances
Primary—secondary: 4.0mm
required
required
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 4.0mm required
240Vrms) —accessible parts /
enclosure: 4.0mm required
Primary (operating voltage:
340Vrms, 1.0kVp) —
accessible parts / enclosure:
5.9mm required
340Vrms, 1.0kVp) —
accessible parts / enclosure:
5.9mm required
L-N before fuse link:
2.0mm required
TR1: P—S: 5.9mm required
TR2: P—S: 4.0mm required
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
with table 8 and, where applicable, table 9
Measured distance:
Primary—secondary: >4.6mm
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): >4.6mm
enclosure (operating voltage:
240Vrms): >4.6mm
Primary—accessible parts /
enclosure (operating voltage:
340Vrms, 1.0kVp): >10mm
enclosure (operating voltage:
340Vrms, 1.0kVp): >10mm
TR1: P—S: >6.0mm
TR2: P—S: >6.0mm
L-N before fuse link: >3.5mm
Pass
page 11 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.4 Creepage
distances
Primary—secondary:
on PCB
track 4.0mm required (PCB
material group I or II).
material group I or II).
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): on PCB track
4.0mm required (PCB material
group I or II).
enclosure (operating voltage:
240Vrms): on PCB track
4.0mm required (PCB material
group I or II).
Primary—accessible parts /
enclosure (operating voltage:
340Vrms, 1.0kVp): on PCB
track 5.9mm required (PCB
material group I or II).
enclosure (operating voltage:
340Vrms, 1.0kVp): on PCB
track 5.9mm required (PCB
material group I or II).
L-N before fuse link:
3.0mm required
TR1: P—S: 5.9mm required
(insulation tape material group
I; margin tape material group II;
PCB material group I or II).
(insulation tape material group
I; margin tape material group II;
PCB material group I or II).
TR2: P—S: 4.4mm required
(insulation tape material group
I; margin tape material group II;
PCB material group I or II).
(insulation tape material group
I; margin tape material group II;
PCB material group I or II).
Pass
Creepage distances greater than table 11 minima
Measured distance:
Primary—secondary: >6.0mm
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): >6.0mm
enclosure (operating voltage:
240Vrms): >6.0mm
Primary—accessible parts /
enclosure (operating voltage:
340Vrms, 1.0kVp): >15mm
enclosure (operating voltage:
340Vrms, 1.0kVp): >15mm
TR1: P—S: >6.0mm
TR2: P—S: >6.0mm
L-N before fuse link: >3.5mm
Pass
13.5 Printed
boards
N/A
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.