page 4 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
3 GENERAL 
REQUIREMENTS 
Pass 
 
Safety class of the apparatus ................................. : ClassII Pass 
 
 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
Yes  
Noted 
 
 
 
5 MARKING 
Pass 
 
Comprehensible and easily discernible 
Printed on the rear enclosure 
Pass 
 
Permanent durability against water and petroleum 
spirit 
 Pass 
5.1 Identification, 
maker, model ................................... : harman/kardon Pass 
 
Class II symbol if applicable 
 
Pass 
 
Rated supply voltage and symbol .......................... : 100-240V ~ 
Pass 
 
Frequency if safety dependant 
50/60Hz Pass 
 
Rated current or power consumption .................... : 380W Pass 
5.2 Earth 
terminal 
Class II 
N/A 
 
Hazardous live terminals 
 N/A 
 
Supply output terminals (other than mains) 
 N/A 
5.3 
Use of triangle with exclamation mark 
On PCB  
Pass 
5.4 
Instructions for use 
 
Pass 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
 Pass 
 
Hazardous live terminals, instructions for wiring 
No such terminals 
N/A 
 
Instructions for replacing lithium battery 
No lithium battery 
N/A 
 
Instructions for modem if fitted 
No modem fitted 
N/A 
 
Class I earth connection warning 
 
N/A 
 
Instructions for multimedia system connection 
 
Pass 
 
Special stability warning for fixed installation 
 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
 Pass 
 
Instructions for permanently connected equipment   
N/A 
 
 
 
 
page 5 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
6 HAZARDOUS 
RADIATION 
Pass 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation 
N/A 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
No ionizing radiation 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... :  Class 1 
Pass 
 
Emission limits under fault conditions .................... :  Laser Optical Pickup:Class 1 
Pass 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
Pass 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table) 
Pass 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
Pass 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
Pass 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier 
(see appended table) 
Pass 
7.1.4 
Temperature rise of windings 
(see appended table) 
Pass 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such supporting parts 
N/A 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
Pass 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB, windings 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools are required 
Pass 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
Pass 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
Tools are required 
Pass 
8.5 
Class I equipment 
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 N/A 
 
 
page 6 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
8.6 
Class II equipment and Class II constructions within 
Class I equipment 
 Pass 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 Pass 
 
Components bridging reinforced or double insulation 
complying with 14.1 a) or 14.3 
TR1, TR2 
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
CY1, CY2, CY3, CY4, CY5, 
CY6 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
No such voltage 
N/A 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V (peak) 
a.c. or between 60 V and 120 V d.c. and hazardous 
live parts at higher voltage 
 N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) :   
N/A 
 
Reinforced insulation > 0,4 mm (mm) .................... :  TR1, TR2 bobbin: 0.8mm 
Optocoupler PH1, PH2: 
0.45mm 
Enclosure: >1.1mm 
Separation sheet on internal 
enclosure under power board: 
0.5mm. 
Pass 
 
Thin sheet insulation 
Inside TR1, TR2 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 
 N/A 
 
 
page 7 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Reinforced insulation, three layers any two which 
meet 10.3 
Withstand 4240Vp test. 
Pass 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts 
           
N/A 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
           
N/A 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts 
Live wires are double 
insulated, no secondary wire 
can come closer to live parts 
Pass 
8.11 
Detaching of wires 
      
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
Mating lock connector used for 
mains. No risk of detached. 
N/A 
 Vibration 
test carried out  ........................................ :  No, see above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
 Pass 
8.14 
Adequate fastening of covers (pull test 50 N for 10 s)  Pass 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges 
Internal wires secured and 
keep enough distance from 
sharp or hot parts. 
Pass 
8.16 
Only special supply equipment can be used 
 N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 
Disconnect device 
Mains plug, power inlet 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
Not used as a disconnect 
device 
N/A 
8.19.2 
Mains switch ON indication 
Not used as a disconnect 
device 
N/A 
8.20 
Switch not fitted in the mains cord 
 
Pass 
8.21 
Bridging components comply with clause 14 
 
N/A 
 
 
 
 
Page of 52