Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate ▷ View online
page 4 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Pass
Safety class of the apparatus ................................. : ClassII Pass
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
Yes
Noted
5 MARKING
Pass
Comprehensible and easily discernible
Printed on the rear enclosure
Pass
Permanent durability against water and petroleum
spirit
spirit
Pass
5.1 Identification,
maker, model ................................... : harman/kardon Pass
Class II symbol if applicable
Pass
Rated supply voltage and symbol .......................... : 100-240V ~
Pass
Frequency if safety dependant
50/60Hz Pass
Rated current or power consumption .................... : 380W Pass
5.2 Earth
terminal
Class II
N/A
Hazardous live terminals
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
On PCB
Pass
5.4
Instructions for use
Pass
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
Pass
Hazardous live terminals, instructions for wiring
No such terminals
N/A
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem fitted
N/A
Class I earth connection warning
N/A
Instructions for multimedia system connection
Pass
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Pass
Instructions for permanently connected equipment
N/A
page 5 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
Pass
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
No ionizing radiation
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1
Pass
Emission limits under fault conditions .................... : Laser Optical Pickup:Class 1
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
Pass
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
Pass
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB, windings
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
Pass
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Tools are required
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
page 6 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
TR1, TR2
Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY1, CY2, CY3, CY4, CY5,
CY6
CY6
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : TR1, TR2 bobbin: 0.8mm
Optocoupler PH1, PH2:
0.45mm
0.45mm
Enclosure: >1.1mm
Separation sheet on internal
enclosure under power board:
0.5mm.
enclosure under power board:
0.5mm.
Pass
Thin sheet insulation
Inside TR1, TR2
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
page 7 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
N/A
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
8.10
Double insulation between conductors connected to
the mains and accessible parts
the mains and accessible parts
Live wires are double
insulated, no secondary wire
can come closer to live parts
insulated, no secondary wire
can come closer to live parts
Pass
8.11
Detaching of wires
N/A
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Mating lock connector used for
mains. No risk of detached.
mains. No risk of detached.
N/A
Vibration
test carried out ........................................ : No, see above
N/A
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N/A
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Pass
8.14
Adequate fastening of covers (pull test 50 N for 10 s) Pass
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Internal wires secured and
keep enough distance from
sharp or hot parts.
keep enough distance from
sharp or hot parts.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
Mains plug, power inlet
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
Not used as a disconnect
device
device
N/A
8.19.2
Mains switch ON indication
Not used as a disconnect
device
device
N/A
8.20
Switch not fitted in the mains cord
Pass
8.21
Bridging components comply with clause 14
N/A