Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
 
 
 
 
 
 
 
 
ZB 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
Pass 
2.6.1 
DK: certain types of Class I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
           
N/A 
13.3.1 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 Pass 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
           
Pass 
 
DK: Class I equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
Class II 
N/A 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
No such part 
N/A 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
Class II 
N/A 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
           
Pass 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
           
Pass 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
N/A 
 
 
page 33 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
No such part 
N/A 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
           
N/A 
 
- protecting rim also tested 
      
N/A 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
           
N/A 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 Pass 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
N/A 
DE: additional markings required in German language: 
N/A 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
           
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
           
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
           
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
           
N/A 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
           
N/A 
 
IT: user instructions in Italian language including a 
conformity declaration 
           
N/A 
 
IT: certification number on the back cover 
           
N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No such part 
N/A 
 
 
 
 
 
 
 
 
 
 
 
 
page 34 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
 
 
 
 
 
 
 
 
 
National differences for CHINA 
(According to CB bulletin No. 107A. These differences are taken from 
IEC60065:1993 and adopted to IEC 60065:2001.)
 
Pass 
 
IEC 60065 sub-clause 4.2.2: Test voltage is 0.9 
times or 1.06 times rated voltage of the 
equipment; GB8898 sub-clause 4.2.2: Test 
voltage is 0.9 times or 1.1 times rated voltage of 
the equipment, which of the equipment used in 
China shall cover 220V±10%, 50Hz. 
 Pass 
 
IEC standard for plug is IEC 60083; The Chinese 
national standard for Plugs is GB1002-1996, 
which is not equivalent with IEC 60083 
 Pass 
 
 
National differences for KOREA 
(According to CB bulletin No. 107A. These differences are taken from 
IEC60065:1998 and adopted to IEC 60065:2001.)
 
Pass 
5.101 
Other marking ; Wording "____ “ or an 
information regulated in IEC Publication 417 
giving high voltage warning to layman shall 
be marked, if an apparatus contains a part more 
than 600volts. 
 N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall 
comply with the Korean requirements (KSC8300 
and 8305). 
 Pass 
31 
Radio frequency interference 
The apparatus shall comply with the relevant 
CISPR requirements.(EMC = EMI + EMS) 
 Pass 
 
 
National differences for SINGAPORE 
(According to CB bulletin No. 107A. These differences are taken from 
IEC60065:1993 and adopted to IEC 60065:2001.)
 
Pass 
 
Throughout the standard, whenever the words "white pine board" appear, insert 
the words "or plywood board" to it. 
Noted 
 
SS 143 Amendment No.1 and No. 2 
 
4.1.3 
Delete "45 % to 75 %" and insert "65 _ 5 %". 
75% maximum in IEC 
60065:2001 
Noted 
7.1 
Resistance to heat without external forces 
Adopt the temperature specified for the tropical 
 Pass 
 
 
page 35 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
conditions. 
8.6 
(9.3.4)* 
Delete the note "A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:2001. 
Noted 
10.2 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120h at a relative humidity of 
93%, ambient temperature 
40
o
Pass 
16 
External flexible cords 
Delete "IEC Publication 227: Polyvinyl Cloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC Publication 245: 
Rubber Insulated Cables of Rated Voltage up to 
and including 450/750V" and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 173: Colours of the Cores of 
Flexible Cables and Cords" whenever they 
appear in this clause. 
 Noted 
16.2 
Delete the notes in small print and insert "A 
nominal cross-sectional area of 0.75 mm
2
 will 
satisfy this requirement". 
 Noted 
16.3b 
(16.4b)* 
Delete "Subclause 3.1 of IEC Publication 227-2: 
Part 2: Test Methods" and insert "Subclause 9.1 
of SS 236": 
9.1 Flexing Test (except for tinsel cords, twisted 
twin and single core cords). 
The test shall be carried out by mieans of the 
apparatus shown in Figure 5. This apparatus has 
a carrier C supporting two pulleys A and B 
arranged so that the cord is horizontal between 
the pulleys. The carrier moves backward and 
forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s. 
A sample of flexible cord fabout 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
as given in Table 1. 
Screene cords in accordance with Table 7 shall 
be tested before application of the screen and 
outer sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The 
restraining clamps D shall be fixed so that the pull 
is always applied by the weight from which the 
carrier is mowing away. The carrier shall make 30 
000 backward and forward movements (60 000 
single strokes). Each conductor of the sample 
 Noted 