Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate ▷ View online
page 32 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
Pass
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Pass
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
Pass
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
Class II
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
No such part
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
Class II
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
Pass
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
Pass
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N/A
page 33 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
No such part
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Pass
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
N/A
5
DE: additional markings required in German language:
N/A
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No such part
N/A
page 34 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
National differences for CHINA
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
Pass
IEC 60065 sub-clause 4.2.2: Test voltage is 0.9
times or 1.06 times rated voltage of the
equipment; GB8898 sub-clause 4.2.2: Test
voltage is 0.9 times or 1.1 times rated voltage of
the equipment, which of the equipment used in
China shall cover 220V±10%, 50Hz.
times or 1.06 times rated voltage of the
equipment; GB8898 sub-clause 4.2.2: Test
voltage is 0.9 times or 1.1 times rated voltage of
the equipment, which of the equipment used in
China shall cover 220V±10%, 50Hz.
Pass
IEC standard for plug is IEC 60083; The Chinese
national standard for Plugs is GB1002-1996,
which is not equivalent with IEC 60083
national standard for Plugs is GB1002-1996,
which is not equivalent with IEC 60083
Pass
National differences for KOREA
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
Pass
5.101
Other marking ; Wording "____ “ or an
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
Pass
31
Radio frequency interference
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
Pass
National differences for SINGAPORE
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
Pass
Throughout the standard, whenever the words "white pine board" appear, insert
the words "or plywood board" to it.
the words "or plywood board" to it.
Noted
SS 143 Amendment No.1 and No. 2
4.1.3
Delete "45 % to 75 %" and insert "65 _ 5 %".
75% maximum in IEC
60065:2001
60065:2001
Noted
7.1
Resistance to heat without external forces
Adopt the temperature specified for the tropical
Adopt the temperature specified for the tropical
Pass
page 35 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
conditions.
8.6
(9.3.4)*
Delete the note "A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:2001.
Noted
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
Pass
16
External flexible cords
Delete "IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V" and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords" whenever they
appear in this clause.
Delete "IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V" and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords" whenever they
appear in this clause.
Noted
16.2
Delete the notes in small print and insert "A
nominal cross-sectional area of 0.75 mm
nominal cross-sectional area of 0.75 mm
2
will
satisfy this requirement".
Noted
16.3b
(16.4b)*
Delete "Subclause 3.1 of IEC Publication 227-2:
Part 2: Test Methods" and insert "Subclause 9.1
of SS 236":
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
Part 2: Test Methods" and insert "Subclause 9.1
of SS 236":
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
Noted