Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate ▷ View online
page 24 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
Operating conditions
Y capacitor: CY3
40.9 / 38.9
50 (85-35)
Y capacitor: CY6
44.9 / 40.2
50 (85-35)
Optocoupler: PH2
42.6 / 40.4
--
PCB between D17 & D18
45.6 / 41.1
75
Winding of LF3
30.4 / 28.8
65*
Electrolytic capacitor: EC18
42.0 / 39.3
80 (105-25)
PCB near AU3
41.4 / 39.7
85
Electrolytic capacitor: AC62
37.6 / 35.5
70 (105-35)
PCB near U4
39.3 / 38.9
75
PCB near Q6
40.2 / 37.9
75
Enclosure (metallic)
21.8 / 22.1
30
Enclosure (non-metallic)
12.9 / 12.9
25 (60-35)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) .................................. :
—
Ambient temperature t2 (
o
C) .................................. :
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
*The limit value reduced by 10K due to the thermal coupler method used.
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
page 25 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>100
2
Between parts separated by basic or supplementary insulation
>100
2
Between parts separated by double or reinforced insulation
4.2
4
10.3
TABLE: electric strength measurements
Pass
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120 Vp
No
Between parts separated by double or reinforced insulation
4240 Vp
No
11.2
TABLE: summary of fault condition tests
Pass
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
—
Ambient temperature (
o
C) ...................................... : 25
—
Working voltage:264V
Under fault conditions specified below
dT (K)
Limit dT (K)
One diode short circuit, fuse FU1 opened immediately.
-
-
EC16 short circuit, fuse FU1 opened immediately.
-
-
PH2 pin 1-2 short circuit, power consumption 26 - 38W, no extreme high
temperature, no hazard. Monitored point: winding of TR1
temperature, no hazard. Monitored point: winding of TR1
57 130
PH2 pin 3-4 short circuit, as normal, no hazard. Monitored point: winding of TR1
51
130
PH1 pin 1-2 short circuit, power consumption <7W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
PH1 pin 3-4 short circuit, power consumption <1W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
EC2 short circuit, power consumption <4W, no high temperature, no hazard.
-
-
EC17 short circuit, R23 opened in few seconds, then power consumption down to
16.3W, audio output on speaker shut down, no high temperature, no hazard.
Monitored point: winding of TR1
16.3W, audio output on speaker shut down, no high temperature, no hazard.
Monitored point: winding of TR1
47 140
D5 short circuit, power consumption <1W, circuit protected. No high temperature,
no hazard.
no hazard.
- -
EC3 short circuit, power consumption 1 - 14W, circuit protected. No high
temperature, no hazard. Monitored point: winding of TR1
temperature, no hazard. Monitored point: winding of TR1
43 130
page 26 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
D6 short circuit, power consumption <2.5W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
EC5 short circuit, power consumption <1W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
D7 short circuit, power consumption 37W, no audio output on speaker. No high
temperature, no hazard. Monitored point: winding of TR1
temperature, no hazard. Monitored point: winding of TR1
55 130
EC7 short circuit, D7 short in 20 seconds, then circuit protected. Power
consumption 1 - 40W. No high temperature, no hazard.
Monitored point: winding of TR1
consumption 1 - 40W. No high temperature, no hazard.
Monitored point: winding of TR1
59 130
D8 short circuit, as normal, no high temperature, no hazard. Monitored point:
winding of TR1
winding of TR1
51 130
EC12 short circuit, power consumption 1.2W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
D9 short circuit, power consumption 3.1W, circuit protected. No high temperature,
no hazard.
no hazard.
- -
EC13 short circuit, D9 short in 20 seconds, then circuit protected. Power
consumption <3W. No high temperature, no hazard.
consumption <3W. No high temperature, no hazard.
- -
One speaker short, power consumption 22W, circuit protected.
Monitored point: winding of TR1
Monitored point: winding of TR1
50 130
Ventilating holes on side enclosure covered, no high temperature, no hazard.
Monitored point: winding of TR1
Monitored point: winding of TR1
54 130
Maximum volume on all loudspeakers, power consumption 133W, circuit
protected in 10s, the power consumption down to 66W, no high temperature, no
hazard.
protected in 10s, the power consumption down to 66W, no high temperature, no
hazard.
- -
Adjust volume on all loudspeakers, and circuit no protected, power consumption
max 73W, 2 hours, no high temperature, no hazard.
Monitored point: winding of LF2
max 73W, 2 hours, no high temperature, no hazard.
Monitored point: winding of LF2
89.5
130
R0 open circuit, the voltage between the pins of mains plug is less than 10V at 2s
after withdrawal of mains plug.
after withdrawal of mains plug.
- -
Winding temperature rise measurements
N/A
Ambient temperature t1 (
o
C) .................................. :
—
Ambient temperature t2 (
o
C) .................................. :
—
page 27 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
14
TABLE: list of critical components and materials
Pass
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Mains plug for
Europe
Europe
Well Shin
Technology
CO., LTD.
WS-019 16A,250V~
DIN VDE 0620-
1:2002
VDE
Mains cord for
Europe
Europe
Well Shin
Technology
CO., LTD.
HO5VV-F
2×0.75mm
2
DIN VDE 0281-5
VDE
Power
Connector
Connector
Well Shin
Technology
CO., LTD.
WS-002E 10A,250V~ IEC
60320
VDE
WS-044-0 10A,250V~ IEC
60320
VDE
Power Inlet
Well Shin
Technology
CO., LTD.
WS-044 10A,250V~ IEC
60320 NEMKO
Mains plug for
Europe,
Indonesia,
Thailand,
Vietnam
Europe,
Indonesia,
Thailand,
Vietnam
LEONI
243 ~250V,2.5A CEE7
VDE
Mains cord for
Europe,
Indonesia,
Thailand,
Vietnam,
Singapore
Europe,
Indonesia,
Thailand,
Vietnam,
Singapore
LEONI
H03VVH2-F
2 x 0,75mm
2
IEC
60227
VDE
Mains plug for
Philippines,
Vietnam
Philippines,
Vietnam
XIANG DELI
ELECTRONICS
(SHENZHEN)
CO LTD
ELECTRONICS
(SHENZHEN)
CO LTD
X301
10A, 125V~
NEMA 1-15
UL: E205425
Mains cord for
Philippines,
Vietnam
Philippines,
Vietnam
SHENZHEN
BAO HING
ELECTRIC
WIRE & CABLE
MFR CO LTD
BAO HING
ELECTRIC
WIRE & CABLE
MFR CO LTD
SPT-2
2 x 18AWG (2 x
0.823mm
2
)
UL 62
UL: E159216
Mains plug for
Korea
Korea
Phino Electrical
Wire & Cable
Co., Ltd.
Wire & Cable
Co., Ltd.
PHP-220
(alternative) LEONI
345K
3A, 250V~
KS C8305
KTL
Mains cord for
Korea
Korea
Phino Electrical
Wire & Cable
Co., Ltd.
Wire & Cable
Co., Ltd.
VCTFK
2 x 0.75mm²
KS C3304
KTL
(alternative) LEONI
VCTFK 2 x 0.75mm²
KS C3304
KTL
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.