page 24 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
Operating conditions 
Y capacitor: CY3 
40.9 / 38.9 
50 (85-35) 
Y capacitor: CY6 
44.9 / 40.2 
50 (85-35) 
Optocoupler: PH2 
42.6 / 40.4 
-- 
PCB between D17 & D18 
45.6 / 41.1 
75 
Winding of LF3 
30.4 / 28.8 
65* 
Electrolytic capacitor: EC18 
42.0 / 39.3 
80 (105-25) 
PCB near AU3 
41.4 / 39.7 
85 
Electrolytic capacitor: AC62 
37.6 / 35.5 
70 (105-35) 
PCB near U4 
39.3 / 38.9 
75 
PCB near Q6 
40.2 / 37.9 
75 
Enclosure (metallic)  
21.8 / 22.1 
30 
Enclosure (non-metallic) 
12.9 / 12.9 
25 (60-35) 
 
 
 
      
Winding temperature rise measurements 
      
      
Ambient temperature t1 (
o
C) .................................. :       
— 
      
Ambient temperature t2 (
o
C) .................................. :       
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)  Insulation 
class 
           
         
         
           
           
           
 
 
 
 
           
         
         
           
           
           
*The limit value reduced by 10K due to the  thermal coupler method used. 
 
7.2 
TABLE: softening temperature of thermoplastics 
N/A 
 
Temperature T of part 
T - normal condi-
tions (
o
C) 
T - fault condi-
tions (
o
C) 
T softening 
(
o
C) 
 
 
 
 
 
 
 
page 25 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
>100 
Between parts separated by basic or supplementary insulation 
>100 
Between parts separated by double or reinforced insulation 
4.2 
 
10.3 
TABLE: electric strength measurements 
Pass 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120Vp 
No 
Between parts separated by basic or supplementary insulation 
2120 Vp 
No 
Between parts separated by double or reinforced insulation 
4240 Vp 
No 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
      
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240 
— 
      
Ambient temperature (
o
C) ...................................... : 25 
— 
 
Working voltage:264V 
Under fault conditions specified below 
dT (K) 
Limit dT (K)
One diode short circuit, fuse FU1 opened immediately. 
EC16 short circuit, fuse FU1 opened immediately. 
PH2 pin 1-2 short circuit, power consumption 26 - 38W, no extreme high 
temperature, no hazard. Monitored point: winding of TR1 
57 130 
PH2 pin 3-4 short circuit, as normal, no hazard. Monitored point: winding of TR1 
51 
130 
PH1 pin 1-2 short circuit, power consumption <7W, circuit protected. No high 
temperature, no hazard. 
- - 
PH1 pin 3-4 short circuit, power consumption <1W, circuit protected. No high 
temperature, no hazard. 
- - 
EC2 short circuit, power consumption <4W, no high temperature, no hazard. 
EC17 short circuit, R23 opened in few seconds, then power consumption down to 
16.3W, audio output on speaker shut down, no high temperature, no hazard. 
Monitored point: winding of TR1 
47 140 
D5 short circuit, power consumption <1W, circuit protected. No high temperature, 
no hazard. 
- - 
EC3 short circuit, power consumption 1 - 14W, circuit protected. No high 
temperature, no hazard. Monitored point: winding of TR1 
43 130 
 
 
page 26 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
D6 short circuit, power consumption <2.5W, circuit protected. No high 
temperature, no hazard. 
- - 
EC5 short circuit, power consumption <1W, circuit protected. No high 
temperature, no hazard. 
- - 
D7 short circuit, power consumption 37W, no audio output on speaker. No high 
temperature, no hazard. Monitored point: winding of TR1 
55 130 
EC7 short circuit, D7 short in 20 seconds, then circuit protected. Power 
consumption 1 - 40W. No high temperature, no hazard.                                  
Monitored point: winding of TR1 
59 130 
D8 short circuit, as normal, no high temperature, no hazard. Monitored point: 
winding of TR1 
51 130 
EC12 short circuit, power consumption 1.2W, circuit protected. No high 
temperature, no hazard. 
- - 
D9 short circuit, power consumption 3.1W, circuit protected. No high temperature, 
no hazard. 
- - 
EC13 short circuit, D9 short in 20 seconds, then circuit protected. Power 
consumption <3W. No high temperature, no hazard. 
- - 
One speaker short, power consumption 22W, circuit protected.                
Monitored point: winding of TR1 
50 130 
Ventilating holes on side enclosure covered, no high temperature, no hazard. 
Monitored point: winding of TR1 
54 130 
Maximum volume on all loudspeakers, power consumption 133W, circuit 
protected in 10s, the power consumption down to 66W, no high temperature, no 
hazard. 
- - 
Adjust volume on all loudspeakers, and circuit no protected, power consumption 
max 73W, 2 hours, no high temperature, no hazard.                                        
Monitored point: winding of LF2 
 
89.5 
 
130 
R0 open circuit, the voltage between the pins of mains plug is less than 10V at 2s 
after withdrawal of mains plug. 
- - 
      
Winding temperature rise measurements 
N/A 
      
Ambient temperature t1 (
o
C) .................................. :       
— 
      
Ambient temperature t2 (
o
C) .................................. :       
— 
 
 
 
 
 
 
 
 
 
 
 
 
 
page 27 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
 
 
 
 
 
14 
TABLE: list of critical components and materials 
Pass 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Mains plug for 
Europe 
Well Shin 
Technology 
CO., LTD. 
WS-019 16A,250V~ 
DIN VDE 0620-
1:2002 
VDE 
Mains cord for 
Europe
 
Well Shin 
Technology 
CO., LTD. 
HO5VV-F  
2×0.75mm
2
 
DIN VDE 0281-5 
VDE 
Power 
Connector  
Well Shin 
Technology 
CO., LTD. 
WS-002E 10A,250V~ IEC 
60320 
VDE 
WS-044-0 10A,250V~ IEC 
60320 
VDE 
Power Inlet  
Well Shin 
Technology 
CO., LTD. 
WS-044 10A,250V~ IEC 
60320  NEMKO 
Mains plug for 
Europe, 
Indonesia, 
Thailand, 
Vietnam
 
LEONI
 
243 ~250V,2.5A CEE7 
VDE 
Mains cord for 
Europe, 
Indonesia, 
Thailand, 
Vietnam, 
Singapore 
LEONI 
H03VVH2-F 
2 x 0,75mm
2
 IEC 
60227 
VDE 
Mains plug for 
Philippines, 
Vietnam 
XIANG DELI 
ELECTRONICS 
(SHENZHEN) 
CO LTD 
X301 
10A, 125V~ 
NEMA 1-15 
UL: E205425 
Mains cord for 
Philippines, 
Vietnam 
SHENZHEN 
BAO HING 
ELECTRIC 
WIRE & CABLE 
MFR CO LTD 
SPT-2 
2 x 18AWG (2 x 
0.823mm
2
UL 62 
UL: E159216 
Mains plug for 
Korea 
Phino Electrical 
Wire & Cable 
Co., Ltd. 
PHP-220 
(alternative) LEONI 
345K 
3A, 250V~ 
KS C8305 
KTL 
Mains cord for 
Korea 
Phino Electrical 
Wire & Cable 
Co., Ltd. 
VCTFK 
2 x 0.75mm² 
KS C3304 
KTL 
(alternative) LEONI 
VCTFK  2 x 0.75mm² 
KS C3304 
KTL 
Page of 52
Display