DOWNLOAD Harman Kardon HS 100 EU (serv.man14) Service Manual ↓ Size: 3.81 MB | Pages: 52 in PDF or view online for FREE

Model
HS 100 EU (serv.man14)
Pages
52
Size
3.81 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-100-eu-sm14.pdf
Date

Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate ▷ View online

 
 
page 20 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
N/A 
 
Picture tube separately approved to IEC 61965: 
No picture tube 
N/A 
 
Picture tube separately approved to 18.1 ............... No 
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
           
N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
           
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
           
N/A 
18.2.1 
Samples subject to ageing: 6 
      
N/A 
18.2.2 
Samples subject to implosion test: 6 
           
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
           
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
           
N/A 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
Pass 
 
Mass of the equipment exceeding 7 kg  ................. : 4.6kg 
N/A 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
N/A 
19.2 
100 N force applied vertically downwards 
 
N/A 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
 N/A 
19.4 
Edges or corners not hazardous 
 
Pass 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surface 
N/A 
19.6 
Wall or ceiling mountings adequate 
Not for wall or ceiling mounting 
N/A 
 
 
 
20 
RESISTANCE TO FIRE 
Pass 
20.1 
Electrical components and mechanical parts 
Pass 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined in 
20.1 
 Pass 
 
 
page 21 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
See components list 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
See components list 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
 Pass 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
See components list 
Pass 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
N/A 
20.2 Fire 
enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
IP20 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
N/A 
 
 
page 22 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1 
Not to be connected to the 
telecommunication networks 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
 
 
 
 
page 23 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
7.1 
TABLE: temperature rise measurements 
Pass 
 
Power consumption in the OFF/Stand-by 
Stand-by: <1.3W  
Pass 
 
Position of the functional switch (W) ...................... : -- 
— 
 
Operating conditions 
Normal DVD playing, with 1/8 non-clipped 1kHz sinusoidal output power to the speaker, operates 4 hours until 
steady condition reached. Ambient 23.5
o
C. 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
90 0.78 44.4 N.A. 
100 0.71 44.0 N.A. 
240 0.38 45.0 N.A. 
264 0.35 45.0 N.A. 
 
      
Loudspeaker impedance (Ω) ................................. : 6 Ω X 5 
— 
      
Several loudspeaker systems 
5 channel speakers 
Pass 
           
Marking of loudspeaker terminals 
Printed on rear enclosure 
Pass 
Monitored point: 
dT (K)              
264V / 90V 
Limit dT (K) 
Power cord 
26.2/ 27.1 
60 
Winding of LF1 
31.4 / 43.8 
65* 
Y capacitor: CY1 
23.6 / 30.1 
50 (85-35) 
X capacitor: CX1 
28.3 / 37.4 
65 (100-35) 
Winding of LF1 
31.8 / 51.8 
65* 
Electrolytic capacitor: EC16 
33.1 / 37.3 
70 (105-35) 
X capacitor: CX2 
29.0 / 36.4 
65 (100-35) 
PCB near BG1 
33.7/ 43.9 
75 
Winding of TR1 
46.2 / 41.0 
65* 
Bobbin of TR1 
45.8 / 40.5 
115 (150-35) 
PCB near TR1 
39.2 / 37.0 
75 
Optocoupler: PH1 
31.1 / 30.3 
-- 
Winding of TR2 
44.4 / 38.4 
65* 
Bobbin of TR2 
46.4 / 39.9 
115 (150-35) 
PCB near TR2 
40.3 / 37.1 
75 
Y capacitor: CY5 
37.4 / 34.1 
50 (85-35) 
Page of 52