Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate ▷ View online
page 20 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
N/A
Picture tube separately approved to IEC 61965:
No picture tube
N/A
Picture tube separately approved to 18.1 ............... No
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
Pass
Mass of the equipment exceeding 7 kg ................. : 4.6kg
N/A
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
supplied with cart or stand
N/A
19.4
Edges or corners not hazardous
Pass
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surface
N/A
19.6
Wall or ceiling mountings adequate
Not for wall or ceiling mounting
N/A
20
RESISTANCE TO FIRE
Pass
20.1
Electrical components and mechanical parts
Pass
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
Pass
page 21 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
See components list
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
See components list
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Pass
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
See components list
Pass
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
IP20
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
page 22 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
N/A
Complies with IEC 62151 clause 1
Not to be connected to the
telecommunication networks
telecommunication networks
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
page 23 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
Stand-by: <1.3W
Pass
Position of the functional switch (W) ...................... : --
—
Operating conditions
Normal DVD playing, with 1/8 non-clipped 1kHz sinusoidal output power to the speaker, operates 4 hours until
steady condition reached. Ambient 23.5
steady condition reached. Ambient 23.5
o
C.
Un (V)
In (A)
Pn (W)
Pout (W)
90 0.78 44.4 N.A.
100 0.71 44.0 N.A.
240 0.38 45.0 N.A.
264 0.35 45.0 N.A.
Loudspeaker impedance (Ω) ................................. : 6 Ω X 5
—
Several loudspeaker systems
5 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
Monitored point:
dT (K)
264V / 90V
Limit dT (K)
Power cord
26.2/ 27.1
60
Winding of LF1
31.4 / 43.8
65*
Y capacitor: CY1
23.6 / 30.1
50 (85-35)
X capacitor: CX1
28.3 / 37.4
65 (100-35)
Winding of LF1
31.8 / 51.8
65*
Electrolytic capacitor: EC16
33.1 / 37.3
70 (105-35)
X capacitor: CX2
29.0 / 36.4
65 (100-35)
PCB near BG1
33.7/ 43.9
75
Winding of TR1
46.2 / 41.0
65*
Bobbin of TR1
45.8 / 40.5
115 (150-35)
PCB near TR1
39.2 / 37.0
75
Optocoupler: PH1
31.1 / 30.3
--
Winding of TR2
44.4 / 38.4
65*
Bobbin of TR2
46.4 / 39.9
115 (150-35)
PCB near TR2
40.3 / 37.1
75
Y capacitor: CY5
37.4 / 34.1
50 (85-35)
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.