Harman Kardon HK 990 (serv.man4) EMC - CB Certificate ▷ View online
Page 4 of 50
Report No. 902952-1
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Test item particulars
.................................................. :
Classification of installation and use............................ : Stationary
Supply Connection ....................................................... : Mains plug
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object.................: N/A (Not Applicable)
- test object does meet the requirement.......................: P (Pass)
- test object does not meet the requirement.................: F (Fail)
Testing
..........................................................................:
Date of receipt of test item ............................................: 16 March 2009
Date (s) of performance of tests ...................................: 26 March – 29 September 2009
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
General product information:
Stereo Amplifier
Stereo Amplifier
Page 5 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
3 GENERAL
REQUIREMENTS
Safety class of the apparatus .................................: Class
II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
Yes
P
5 MARKING
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
a), b)
Identification, maker, model ....................................: HK 990, Harman/Kardon
P
c)
Class II symbol if applicable
P
d), e)
Rated supply voltage and symbol ..........................: 110-120V~
P
f)
Frequency if safety dependant
60Hz
P
g), h), i)
Rated current or power consumption .....................: 1000W
P
5.2 a)
Earth terminal
N/A
b)
Hazardous live terminals
N/A
c)
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
Only in schematics diagram
P
5.4
Instructions for use
5.4.1
a)
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
P
b)
Hazardous live terminals, instructions for wiring
N/A
c)
Instructions for replacing lithium battery
N/A
Instructions for modem if fitted
N/A
d)
Class I earth connection warning
N/A
e)
Instructions for multimedia system connection
N/A
f)
Special stability warning for fixed installation
N/A
g)
Batteries not exposed to heat/sun warning
P
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
P
Instructions for permanently connected equipment
N/A
Page 6 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ....:
N/A
Emission limits under fault conditions ....................:
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
any single protective device defeated except those
of Cl. 7.1 a) and b)
(See appended table)
P
7.1.1
Temperature rise of accessible parts
(See appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(See appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(See appended table)
P
7.1.4
Temperature rise of windings
(See appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(See appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
o
C
N/A
8 CONSTRUCTIONAL
REQUIREMENTS
WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No such material used.
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
No removal by hand.
N/A
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Page 7 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
T1, T2, T3, T4
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
This sub-clause is void
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) .......................................:
insulation > 0.4 mm (mm) .......................................:
N/A
Reinforced insulation > 0.4 mm (mm) ....................: T1
and
T4
P
Thin sheet insulation used inside the enclosure.
T2/T3
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
10.3 dielectric
N/A
Reinforced insulation, three layers any two which
meet 10.3 dielectric
meet 10.3 dielectric
P
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
internal hazardous live conductors and accessible
parts
P
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
internal hazardous live parts and conductors
connected to accessible parts
P
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
conductors connected to accessible parts and the
mains
Primary wires are double
insulated.
Secondary wires can not come
into contact with live parts.
P
Click on the first or last page to see other HK 990 (serv.man4) service manuals if exist.