Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg .................: 23.8kg
P
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
Apparatus mass > 25 kg or height > 1 m or supplied
with cart or stand. Topple test.
with cart or stand. Topple test.
N/A
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces with an area exceeding 0.1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
N/A
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Page 21 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Apparatus with voltages > 4 kV under normal
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
N/A
20.2
Fire enclosure
20.2.1 Potential
ignition
sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
1 mm in width and with openings for wires
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 22 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES
PURPOSES
L.5.4
Battery chargers and supply apparatus marked with
model number.
model number.
N/A
L7.1.5
Lithium batteries: temperature rise (Normal)
N/A
L.9.1.1 Flash
synchroniser
teminals not hazardous live.
N/A
L.11.2.6 Lithium
batteries:
temperature rise (Fault).
N/A
L.14.6.6
Peak surge current and rated mains current not to
exceed mains switch current rating
exceed mains switch current rating
N/A
Page 23 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
7.1
TABLE: temperature rise measurements: Conditions
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W)………..….:…………....:
the functional switch (W)………..….:…………....:
1.2W
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1 132 60 5.2 492 14
48
2 120 60 4.9 440 13
40
3 99 60 4.0 297 10 26
1/8 of max output. Pink noise at
CD input.
CD input.
Loudspeaker impedance (Ω) ................................. :
2 x 4
—
Several loudspeaker systems
2 separate 2 channel systems
P
Marking of loudspeaker terminals
P
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 1
No ___
No ___
1. Fuse board PCB
29
85
2. T1 Bobbin
30
85
3. T4 Bobbin
32
85
4. C3 body
33
-
5. T3 winding
38
70
6. Mains cable
24
60
7. Power board PCB
36
75
8. C7 body
30
-
9. Front metal enclosure
10
40
10. Front plastic knob
17
50
11.Top metal enclosure
10
40
12. Heat sink (accessible by hand)
40
65
Click on the first or last page to see other HK 990 (serv.man4) service manuals if exist.