Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg .................:  23.8kg 
 
Apparatus intended to be fastened in place – 
suitable instructions 
 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
Apparatus mass > 25 kg or height > 1 m or supplied 
with cart or stand. Topple test. 
 
N/A 
19.4 
Edges or corners not hazardous 
 
19.5 
Glass surfaces with an area exceeding 0.1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
 
N/A 
19.6 
Wall or ceiling mountings adequate 
 
N/A 
 
20 
RESISTANCE TO FIRE 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 
N/A 
 
b) Exemption for small components as defined in 
20.1 mounted on a board of flammability category of 
V-1 to IEC 60695-11-10 
 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure 
 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
 
N/A 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
N/A 
 
Page 21 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Apparatus with voltages > 4 kV under normal 
conditions, and distances to enclosure exceed 
those specified by Table 21, HB40 min enclosure 
 
N/A 
20.2 
Fire enclosure 
20.2.1 Potential 
ignition 
sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 
N/A 
 
Page 22 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
N/A 
 
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1 
 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard 
 
N/A 
 
Complies with IEC 62151 clause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC 
PURPOSES 
 
L.5.4 
Battery chargers and supply apparatus  marked with 
model number. 
 
N/A 
L7.1.5 
Lithium batteries: temperature rise (Normal) 
 
N/A 
L.9.1.1 Flash 
synchroniser 
teminals not hazardous live. 
 
N/A 
L.11.2.6 Lithium 
batteries: 
temperature rise (Fault). 
 
N/A 
L.14.6.6 
Peak surge current and rated mains current not to 
exceed mains switch current rating 
 
N/A 
 
Page 23 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
7.1 
TABLE: temperature rise measurements: Conditions 
 
Power consumption in the OFF/Stand-by mode of 
the functional switch (W)………..….:…………....: 
1.2W  
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
1 132 60 5.2 492  14 
48 
2 120 60 4.9 440  13 
40 
3 99 60 4.0 297  10  26 
1/8 of max output. Pink noise at 
CD input.  
 
 
 
 
 
 
 
 
 
 
Loudspeaker impedance (Ω)  ................................. : 
2 x 4 
— 
 
Several loudspeaker systems 
2 separate 2 channel systems 
 
Marking of loudspeaker terminals 
 
 
Temperature Rise dT of Part
 
dT (K) 
Limit max dT (K) 
Test Condition No. 
No 1 
No ___ 
No ___ 
 
1. Fuse board PCB 
29 
 
 
85 
2. T1 Bobbin 
30 
 
 
85 
3. T4 Bobbin 
32 
 
 
85 
4. C3 body 
33 
 
 
5. T3 winding 
38 
 
 
70 
6. Mains cable 
24 
 
 
60 
7. Power board PCB 
36 
 
 
75 
8. C7 body 
30 
 
 
9. Front metal enclosure 
10 
 
 
40 
10. Front plastic knob 
17 
 
 
50 
11.Top metal enclosure 
10 
 
 
40 
12. Heat sink (accessible by hand) 
40 
 
 
65 