DOWNLOAD Harman Kardon HK 990 (serv.man4) Service Manual ↓ Size: 3.2 MB | Pages: 64 in PDF or view online for FREE

Model
HK 990 (serv.man4)
Pages
64
Size
3.2 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-990-sm4.pdf
Date

Harman Kardon HK 990 (serv.man4) EMC - CB Certificate ▷ View online

 
Page 24 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) .............................
Ambient temperature t2 (
o
C) .............................
23 
24 
 
 
— 
— 
 
 
 
 
— 
— 
 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) – (t2 – t1)
             R
1
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit 
maxK) 
Insulation class 
T1 prim. winding (stand-by transf.) 
1720 
1920 
29 
70 
Class A 
T4 prim. winding (connected at CN9) 
20.0 
23.0 
37 
70 
Class A 
T2 prim. winding (connected at CN8) 
1.4 
1.6 
36 
70 
Class A 
T3 prim. winding (connected at CN7) 
1.4 
1.6 
36 
70 
Class A 
 
9.1 
Shock Hazard  
 
Under normal operating conditions: > 35Vpk ac / 60V dc 
 
Notes:  Reference Annex D  
 
CLASS I: (single phase) 
 AC 
DC 
 
U1:            -        Vpk 
-          mA rms 
U1:           -           V 
-            mA 
 
 
 
 
U2:            -        Vpk 
-         mA rms 
 
 
 
 
 
 
 
CLASS II: (single phase)  
 
U1:        0.5          Vpk 
-      mA rms 
U1:           -           V 
-          mA 
 
 
 
 
U2:       0.1           Vpk 
0.14  mA rms 
 
 
 
 
 
 
 
 
 
Page 25 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
10.3 
TABLE: Insulation Resistance Measurements 
Insulation resistance R between: 
R (MΩ) 
Min 
required R 
(MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation 
Between parts separated by double or reinforced insulation 
100 
 
10.3 
TABLE: Electric Strength Measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
1414 (peak) 
No 
Between parts separated by basic or supplementary insulation 
Between parts separated by double or reinforced insulation 
2828 (peak) 
No 
 
 
Page 26 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.1 times rated voltage .............:  110-120 
— 
 Frequency 
(Hz)……………………………………..: 
60 
— 
 Ambient 
temperature 
(
o
C) .......................................: 21-25 
— 
 
No 
Component 
Fault 
Temp Rise/ 
Component 
Other results 
(include description and test duration) 
1 Output 100%  - 
Un=132V, 
Pout=380W/channel 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
Fan 
Blocked             
(fan near T2) 
Main PCB= 47K 
T2 winding= 83K 
T4 winding= 54K 
Un=132V, In=5.2A 
Test duration=1h 
Apparatus goes to protective mode after 
1h. No high temp, no hazard. 
3 Ventilation 
Covered 
Main 
PCB= 
50K 
T2 winding= 90K 
T4 winding= 62K 
Un=132V, In=5.2A 
Test duration=1h 
Apparatus goes to protective mode after 
1h. No high temp, no hazard. 
4 Speaker 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard.
 
5 D6 
s.c 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
6 C26  s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
7 C71  s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
8 D7 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
 
Page 27 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
9 C72  s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
10 D3 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
11 D5 
s.c. 
-- 
Un=99/132V 
Test duration=1min. 
Mains fuse opens immediately. No high 
temp, no hazard. 
12 C3 
s.c. 
-- 
See 
fault 
11 
13 Q5 
s.c. 
-- 
See 
fault 
11 
14 C18 
s.c. 
-- 
See 
fault 
11 
15 C3 
s.c. 
-- 
Un=99V 
Test duration=5min. 
Mains fuse opens. No high temp, no 
hazard. 
16 
IC4 (pin 2-3) 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
17 
IC2 (pin 1-2) 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C) .................................. : -- 
— 
 
Ambient temperature t2 (
o
C) .................................. : -- 
— 
 
Page of 64
Display

Click on the first or last page to see other HK 990 (serv.man4) service manuals if exist.