Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
15.1.1
Norway
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with
the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply
with the enclosed Standard Sheet I.
See EN 60065:2002
Other dimensions according to CEE Publication 7
Standard Sheet I "Portable Single-Way Socket-
Outlets".
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with
the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply
with the enclosed Standard Sheet I.
See EN 60065:2002
Other dimensions according to CEE Publication 7
Standard Sheet I "Portable Single-Way Socket-
Outlets".
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification
:
Act of 24 May 1929 relating to supervision of
electrical installation
(TEA 1929/FEL 1998).
electrical installation
(TEA 1929/FEL 1998).
N
15.1.1
United Kingdom
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a "standard plug" in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a "standard plug" in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE "Standard plug" is defined in SI 1768:1994 and
essentially means an approved plug
conforming to BS 1363 or an approved conversion plug.
Justification
:
SI 1768: 1994
Not
Checked
Page 42 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
J.2
Norway
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
N
Page 43 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Annex B
Norway
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of
IEC 62151:2000 (ref. Corrigendum 1 and 2 to
IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE – In Norway, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLES parts, have a marking stating
that the equipment must be connected to an
earthed mains socket-outlet. The marking text
shall be as follows:
“Apparatet skal tilkoples jordet stikkontakt”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is
added between the first and second paragraph
(this text is identical to the test in EN 60950-
1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of
IEC 62151:2000 (ref. Corrigendum 1 and 2 to
IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE – In Norway, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLES parts, have a marking stating
that the equipment must be connected to an
earthed mains socket-outlet. The marking text
shall be as follows:
“Apparatet skal tilkoples jordet stikkontakt”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is
added between the first and second paragraph
(this text is identical to the test in EN 60950-
1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
-
two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
which shall pass the electric strength test
below, or
-
one layer having a distance through
insulation of at least 0,4mm, which shall
pass the electric strength test below.
insulation of at least 0,4mm, which shall
pass the electric strength test below.
N
Page 44 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Annex B
(cont)
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casting, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in the accordance with the
compliance clause below and in addition:
-
passes the test and inspection criteria of
13.6 with and electric strength test of
10.3 using the test voltage of 1,5kV
multiplied by 1,6, and
13.6 with and electric strength test of
10.3 using the test voltage of 1,5kV
multiplied by 1,6, and
-
is subject to routine testing for electric
strength during manufacturing, using a
test voltage of 1,5kV (for performance of
the test see N.2.1).
strength during manufacturing, using a
test voltage of 1,5kV (for performance of
the test see N.2.1).
It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the
following conditions:
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the
following conditions:
-
the insulation requirements are satisfied
by having a capacitor classified Y3 as
defined by IEC 60384-14, which in
addition to the Y3 testing, is tested with
an impulse test of 2,5kV defined in IEC
62151, subclause 6.2.1;
by having a capacitor classified Y3 as
defined by IEC 60384-14, which in
addition to the Y3 testing, is tested with
an impulse test of 2,5kV defined in IEC
62151, subclause 6.2.1;
-
the additional testing shall be performed
on all the test specimens as described in
IEC 60384-14;
on all the test specimens as described in
IEC 60384-14;
-
the Impulse test of 2,5kV is to be
performed before the Endurance Test in
IEC 60384-14 in the sequence of tests as
described in IEC 60384-14.
performed before the Endurance Test in
IEC 60384-14 in the sequence of tests as
described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE – In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals
or other reliable means, and for equipment which
is intended for connection to the building
installation wiring via an industrial plug and
socket-outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
N