Harman Kardon HK 970 (serv.man13) EMC - CB Certificate ▷ View online
Page 37 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
(Cont)
Publication Date Title
EN/HD
Date
IEC 60695-11-10 1999
Part 11-10: Test flames – 50 W horizontal
EN 60695-11-10 1999
and vertical flame test methods
IEC 60707
1999
Flammability of solid non-metallic
EN 60707
1999
materials when exposed to flame sources
– List of test methods
IEC 60730 (mod) series
Automatic electrical controls for household
EN 60730 series
and similar use
IEC 60825-1
1993
Safety of laser products
EN 60825-1
1994
corr. December 1994
Part 1: Equipment classification,
+ corr. February 1995
A1
1997
requirements and user's guide
+ A11
1996
+
corr.
July
1997
A2 2001
A2 2001
IEC 60851-3
1996
Winding wires - Test methods
EN 60851-3
1996
Part 3: Mechanical properties
IEC 60851-5
1996
Part 5: Electrical properties
EN 60851-5
1996
IEC 60851-6
1996
Part 6: Thermal properties
EN 60851-6
1996
IEC 60884
series
Plugs and socket-outlets for household and
-
-
similar
purposes
IEC 60885-1
1987
Electrical test methods for electric cables
-
-
Part 1: Electrical tests for cables, cords
and wires for voltages up to and including
450/750
V
IEC 60906
series
IEC system of plugs and socket-outlets for
-
-
household and similar purposes
IEC 60950 (mod) 1999
Safety of information technology
EN 60950
11)
2000
+ corr. January 2000
equipment
+ corr. February 2002
IEC 60990
1999
Methods of measurement of touch-current
EN 60990
1999
and protective conductor current
IEC 60998-2-2 1991
Connecting devices for low-voltage circuits
EN 60998-2-2 1993
for household and similar purposes
Part 2-2: Particular requirements for
connecting devices as separate entities
with screwless-type clamping units
IEC 60999-1
1999
Connecting devices - Safety requirements
EN 60999-1
2000
for screw-type and screwless-type
clamping
units
Part 1: General requirements and
particular requirements for clamping units
for conductors from 0,2mm
2
up to 35 mm
2
(included)
IEC 61032
1997
Protection of persons and equipment by
EN 61032
1998
enclosures Probes for verification
———————
11)
EN 60950 is superseded by EN 60950-1:2001 (IEC 60950-1:2001, mod.).
Noted
Page 38 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
(Cont)
Publication Date Title
EN/HD
Date
IEC 61051-2
1991
Varistors for use in electronic equipment
-
-
Part 2: Sectional specification for surge
suppression
varistors
IEC 61058-1
1996
Switches for appliances
-
12)
-
Part
1:
General
requirements
IEC/TR2 61149 1995
Guide for safe handling and operation of
-
-
mobile radio equipment
IEC 61260
1995
Electroacoustics - Octave-band and
EN 61260
1995
fractional-octave-band
filters
IEC 61293
1994
Marking of electrical equipment with
EN 61293
1994
ratings related to electrical supply - Safety
requirements
IEC 61558-1
1997
Safety of power transformers, power
EN 61558-1
1997
(mod)
supply units and similar
A1
1998
Part 1: General requirements and tests
A1
1998
IEC 61558-2-17 1997
Part 2-17: Particular requirements for
EN 61558-2-17 1997
transformers for switch mode power
supplies
IEC 61965
2000
Mechanical safety of cathode ray tubes
EN 61965
2001
IEC 62151
2000
Safety of equipment electrically connected
-
-
to a telecommunication network
IEC Guide 104 1997
The preparation of safety publications
-
and the use of basic safety publications
and group safety publications
ISO 262
1973
ISO general purpose metric screw threads
-
-
- Selected sizes for screws, bolts and nuts
ISO 306
1994
Plastics - Thermoplastic materials -
-
-
Determination of Vicat softening
temperature
(VST)
ISO 7000
1989
Graphical symbols for use on equipment -
-
-
Index
and
synopsis
ITU-T
1988
Tests on power-fed repeaters using
-
-
Recommendation
solid-state devices in order to check the
K.17
arrangements for protection from
external
interference
ITU-T
1996
Resistibility of subscriber's terminal to
-
-
Recommendation
overvoltages and overcurrents
K.21
———————
12) IEC 61058-1:2000 + A1:2001, mod., are harmonized as EN 61058-1:2002.
Noted
Page 39 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Annex ZB
(normative)
Special national conditions
(normative)
Special national conditions
Special national condition:
National characteristic or practice that cannot be changed even over a long
period, e.g. climatic conditions, electrical earthing conditions. If it affects harmonization, it forms part of the
European Standard or Harmonization Document.
For the countries in which the relevant special national condition apply these provisions are normative, for
other countries they are informative.
European Standard or Harmonization Document.
For the countries in which the relevant special national condition apply these provisions are normative, for
other countries they are informative.
2.6.1
Denmark
The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socketoutlets
Justification:
Heavy Current Regulations, Section 107
The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socketoutlets
Justification:
Heavy Current Regulations, Section 107
Class II apparatus
N
13.3.1
Norway
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
N
Page 40 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
15.1.1
Denmark
To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-
D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall have the following dimensions:
See EN 60065:2002
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket
outlets. Shutters are not required
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with HeavyCurrent Regulations
Section 107-2-D1, Standard sheet DK 1-3a, DK
1-5a or DK 1-7a
Justification
To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-
D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall have the following dimensions:
See EN 60065:2002
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket
outlets. Shutters are not required
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with HeavyCurrent Regulations
Section 107-2-D1, Standard sheet DK 1-3a, DK
1-5a or DK 1-7a
Justification
:
Heavy Current Regulations, Section 107
Class II apparatus
No socket outlet
P
15.1.1
Ireland
Apparatus which is fitted with a flexible cable or
cord shall be provided with a plug in accordance
with Statutory Instrument 525: 1997, “13 A Plugs
and Conversion Adapters for Domestic Use
Regulations: 1997.
Justification
Apparatus which is fitted with a flexible cable or
cord shall be provided with a plug in accordance
with Statutory Instrument 525: 1997, “13 A Plugs
and Conversion Adapters for Domestic Use
Regulations: 1997.
Justification
:
SI 525: 1997
Not