Harman Kardon HK 970 (serv.man13) EMC - CB Certificate ▷ View online

 
 
Page 17 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................. :
Marking for mains transformer: 
Trademark: 
 
Type no.: NC-V3075TM4 
Marking for stand-by 
transformer: 
Trademark: 
 
Type no.: T07292A 
 
Transformers and inductors separately approved  : No, tested with appliance 
Noted 
14.3.2 General 
 P 
14.3.3 Constructional 
requirements 
 P 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
Complied with clause 13 
14.3.3.2 
Transformers meet the constructional 
requirements 
           
 
 
Page 18 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
1.  Creepage distance and 
clearance of mains 
transformer between: 
−  Primary winding and 
accessible iron core (along 
bobbin): 7,4mm 
−  Primary winding and 
secondary winding (along 
bobbin): 8,27mm 
−  Primary winding and 
secondary winding (via iron 
core): 7,4mm 
(Limits: (Cr.) 
≥ 4,6mm;  
(Cl.) 
≥ 4,0mm) 
2. Clearance 
of 
mains 
transformer between: 
−  Primary winding and 
accessible iron core (along 
bobbin): 7,8mm 
(Limit: 
≥ 4,0mm) 
3. Creepage 
distance 
and 
clearance of stand-by 
transformer between: 
−  Primary winding and 
accessible iron core: 
6,15mm 
−  Primary winding and 
secondary winding (via iron 
core): 7,35mm 
(Limits: (Cr.) 
≥ 4,6mm;  
(Cl.) 
≥ 4,0mm) 
 
Coil formers and partition walls 
≥ 0,4 mm 
 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
 
 
Page 19 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Insulation between: 
1. Primary 
winding 
to 
accessible iron core of 
mains and stand-by 
transformers fulfil 4240V 
peak (reinforced 
insulation) 
2. Primary 
winding 
to 
secondary winding of 
mains and stand-by 
transformers fulfil 4240V 
peak (reinforced 
insulation) 
 
Coil formers and partition walls  
≥ 0,4 mm 
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No such component 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
 
Page 20 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
(Cont’d) 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Creepage distance and 
clearance measured between: 
1.  Poles of mains fuse-link 
(FUSE) on power switch 
board: 11,5mm  
2.  Poles of thermal fuse 
inside mains transformer: 
3,9mm 
3.  Poles of thermal fuse 
inside stand-by 
transformer: 3,6mm 
(Limits: (Cr.) 
≥ 2,3mm;  
(Cl.) 
≥ 2,0mm) 
Creepage distance and 
clearance measured on power 
amplifier board and between: 
4.  Poles of secondary fuse-
link (F1): 10,3mm 
5.  Poles of secondary fuse-
link (F2): 8,8mm 
(Limits: (Cr.) 
≥ 1,2mm;  
(Cl.) 
≥ 1,0mm) 
Creepage distance and 
clearance measured on power 
supply board and between: 
6.  Poles of secondary fuse-
link (F601): 2,6mm 
7.  Poles of secondary micro 
fuse (F602): 2,8mm 
8.  Poles of secondary micro 
fuse (F603): 2,6mm 
(Limits: (Cr.) 
≥ 1,2mm;  
(Cl.) 
≥ 1,0mm) 
14.5.1.1 
a) Thermal cut-outs separately approved 
SW1 was complied with 
IEC60730 
 
b) Thermal cut-outs tested as part of the 
submission 
 N 