DOWNLOAD Harman Kardon HK 970 (serv.man13) Service Manual ↓ Size: 4.61 MB | Pages: 98 in PDF or view online for FREE

Model
HK 970 (serv.man13)
Pages
98
Size
4.61 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-970-sm13.pdf
Date

Harman Kardon HK 970 (serv.man13) EMC - CB Certificate ▷ View online

 
 
Page 9 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
8.7 
Basic insulation between parts at 35V to 71V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
No such circuit 
 
Reinforced or double insulation between circuits 
operating at voltages between 35V and 71V (peak) 
a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 N 
 
Separation by Class II isolating transformer 
 N 
 
Separation by Class I transformer 
 N 
 
Separation by earthed conductive part 
 N 
8.8 
Basic or supplementary insulation 
≥ 0,4 mm (mm) :  N 
 Reinforced 
insulation 
≥ 0,4 mm (mm) ................... : 1. Bobbin thickness between 
primary winding and 
accessible iron core of 
mains transformer: 
1,67mm 
2. Bobbin 
thickness 
between 
primary winding and 
secondary winding of 
mains transformer: 
1,94mm 
3. Bobbin 
thickness 
between 
primary winding and 
accessible iron core of 
stand-by transformer: 
0,65mm 
4. Bobbin 
thickness 
between 
primary winding and 
secondary winding of 
stand-by transformer: 
1,37mm 
5. Plastic 
enclosure 
thickness: 2,9mm 
6. Heat-shrinkable 
tubing 
that enclosed power 
switch board with 
thickness: 0,42mm 
 Thin 
sheet 
insulation 
 
 
 
Page 10 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 
 
Reinforced insulation, two layers each of which 
meet 10.3 
2 layers of insulating tape 
enclosed primary winding of 
stand-by transformer, each 
layer with thickness of 0,04mm 
and fulfils 4240Vpeak 
(reinforced insulation) 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
1.  Thickness of double 
insulated primary lead 
wires of mains transformer 
and power cord wires: 
1,2mm 
2.  Thickness of double 
insulated primary lead 
wires of stand-by 
transformer: 0,8mm 
3.  Thickness of double 
insulated primary wires of 
mains fuse-link (FUSE): 
0,74mm 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
Basic insulated secondary wire 
cannot touch live parts       
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
Double insulated primary wires 
fulfil 4240V peak 
 
 
Page 11 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
8.11 
Detaching of wires      
 
No undue reduction of creepages or clearance 
distances if wires become detached 
1.  Primary lead wires of 
mains and stand-by 
transformer; mains fuse-
link (FUSE) and power 
cord wires were soldered 
to PCB through eye-lets 
terminals and fixed by 
glue and cable-ties 
2.  Primary lead wires of 
mains fuse-link (FUSE) 
were soldered to terminals 
of fuse-holder by hook-in 
method which enclosed by 
heat-shrinkable tubing and 
fixed by glue and cable-
ties 
3.  Secondary lead wires of 
stand-by transformer were 
soldered to PCB through 
eye-lets terminals and 
fixed by glue 
4.  Secondary lead wires of 
mains transformer and 
other secondary wires 
connected to PCB with 
connector terminals and 
fixed by cable-ties 
 
Vibration test carried out  ....................................... : Yes, no damage 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 
8.16 
Only special supply equipment can be used 
Not this type of equipment 
 
 
Page 12 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
8.17 
Insulated winding wire without additional 
interleaved insulation 
No such wire 
8.18 
Endurance test as required by 8.17 
 
8.19 
Disconnection from the mains 
8.19.1 
Disconnect device 
Mains plug used and complied 
with clause 5.4.2(a) 
 
All-pole switch or circuit breaker with 
≥3mm 
contact separation 
No such device 
8.19.2 
Mains switch ON indication 
No such device 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
No such component 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such circuit 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................ :
Measured maximum: 
U1: 314,0mV peak < 35Vpeak 
U2: 22,8mV peak < 0,35Vpeak 
 
Discharge not exceeding 45 µC 
Measured discharge: 47,3nC 
 
Energy of discharge not exceeding 350 mJ 
Open circuit voltage < 15kV 
9.1.1.2 
Test with test finger and test probe 
No hazardous live parts 
became accessible 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 N 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
Top ventilation holes < 4mm 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2,5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No such device 
Page of 98
Display