Harman Kardon HK 970 (serv.man13) EMC - CB Certificate ▷ View online
Page 13 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2s :
withdrawal of the mains plug; voltage (V) after 2s :
Measured max. votlage:
0.115mVdc
0.115mVdc
P
If C is not greater than 0,1 µF no test needed
Measured capacitance: 0,18
µF P
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) ... : 100N used, no damage
P
9.2
No hazard after removing a cover by hand
Tools are required
N
10 INSULATION
REQUIREMENTS
10.1 Insulation
resistance
(MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ............................................................... :
insulation ............................................................... :
Clause 10.3 was complied
P
10.2
Humidity treatment 48 h or 120 h .......................... : 48h P
10.3
Insulation resistance and dielectric strength
(see appended table)
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
(see appended table)
P
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Page 14 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
N
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
Measured mass: 12,7kg > 7kg;
no damage
no damage
P
12.1.2
Vibration test
No damage
P
12.1.3
Impact hammer test
No damage
P
Steel ball test
No damage
P
12.1.4
Drop test for portable apparatus where mass
≤ 7
kg
Not portable apparatus
N
12.1.5
Thermoplastic enclosures stress relief test
After 7h with used temperature
70
70
°C, hazardous live parts did
not become accessible
P
12.2
Fixing of knobs, push buttons, keys and levers
No such device
N
12.3
Remote controls with hazardous live parts
No such device
N
12.4
Drawers (pull test 50 N, 10 s)
N
12.5
Antenna coaxial sockets providing isolation
No such device
N
12.6
Telescoping or rod antennas construction
No such device
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pollution degree: 2
P
Creepage distances in accordance with 13.4
Pollution degree: 2 and
material group IIIb
material group IIIb
P
13.2
Determination of operating voltage
Operating voltage: 230V
P
13.3
Clearances
Page 15 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Clearance measured between
different polarity of mains at:
different polarity of mains at:
− Power cord wires: 10,9mm
(measured on power switch
board)
board)
(Limit:
≥ 2,0mm)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
P
13.4
Creepage distances
Creepage distances greater than table 11 minima Creepage distance measured
between different polarity of
mains at:
mains at:
− Power cord wires: 10,9mm
(measured on power switch
board)
board)
(Limit:
≥ 2,3mm)
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
P
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N
Page 16 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
14 COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such component
N
a) Resistors separately approved
………………….:
………………….:
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
R901 (Open and short circuit
does not affect safety issue)
does not affect safety issue)
N
b) Resistors separately approved ......................... : N
14.2
Capacitors and RC units
Capacitors separately approved
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : No such component
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : C902, C903
(X2 capacitors used)
C901 (Y2 capacitor used)
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such capacitor
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ..................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ..................................................................... :
No such capacitor
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ....................................... :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ....................................... :
N
Shielded by a barrier to V-0 or metal .................... :
N
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Tested with appliance
Noted