Harman Kardon HK 970 (serv.man13) EMC - CB Certificate ▷ View online
Page 57 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Monitored point:
Under fault conditions specified below
dT (K)
Limit dT (K)
Short C610
Un (V) = 253,0; Pn W = 101,8; In mA = 579,7
-- --
Iron core of mains transformer
3,3
For reference
Primary winding of mains transformer
3,8
150
Secondary winding of mains transformer
3,5 150
Iron core of standy-by transformer
20,6
For reference
Primary winding of standy-by transformer
23,1
150
Secondary winding standy-by transformer
23,7 150
Power cord wire
8,7
100
Secondary lead wire of mains transformer
7,1
100
PCB Surface (near D606)
26,8 110
PCB Surface (near D505)
22,2 110
Enclosure (metallic/ top/ near power amplifier board)
12,3 65
Result: No Hazard; Test time = 30mins
Components F602 and F603 were burnt at once, and no higher temperature rise occurred. This test was
repeated 3 times and result was the same. Clause 14.5.4 was considered and complied.
Monitored point:
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short C606
Un (V) = 253,0; Pn W = 13,1; In mA = 74,8
-- --
Result: No Hazard;
Fuse-link F601 was opened at once.
Fuse-link current of F601 was 2,9A.
The input power was less than normal operation and no higher temperature rise occurred.
Page 58 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short C606
Un (V) = 207,0; Pn W = 8,2; In mA = 47,1
-- --
Result: No Hazard;
Fuse-link F601 was opened at once.
Fuse-link current of F601 was 7,9A.
The input power was less than normal operation and no higher temperature rise occurred.
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short D606
Un (V) = 253,0; Pn W = 11,4; In mA = 72,5
-- --
Result: No Hazard;
Fuse-link F601 was opened at once.
Fuse-link current of F601 was 6,3A.
The input power was less than normal operation and no higher temperature rise occurred.
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short D606
Un (V) = 207,0; Pn W = 8,3; In mA = 50,2
-- --
Result: No Hazard;
Fuse-link F601 was opened at once.
Fuse-link current of F601 was 5,6A.
The input power was less than normal operation and no higher temperature rise occurred.
Page 59 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short C17
Un (V) = 253,0; Pn W = 111,0; In mA = 621,6
-- --
Result: No Hazard;
Fuse-link F1 was opened at once.
Fuse-link F2 was opened at once.
Fuse-link current of F1 was 16,0A.
Fuse-link current of F2 was 16,0A.
The input power was less than normal operation and no higher temperature rise occurred.
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short C17
Un (V) = 207,0; Pn W = 84,7; In mA = 568,9
-- --
Result: No Hazard;
Fuse-link F1 was opened at once.
Fuse-link F2 was opened at once.
Fuse-link current of F1 was 14,7A.
Fuse-link current of F2 was 14,7A.
The input power was less than normal operation and no higher temperature rise occurred.
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short BR1 (“+” and “AC”)
Un (V) = 253,0; Pn W = 202,9; In mA = 1064,2
-- --
Result: No Hazard;
Fuse-link F1 was opened at once.
Fuse-link current of F1 was 19,4A.
The input power was similar to normal operation and no higher temperature rise occurred.
Page 60 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short BR1 (“+” and “AC”)
Un (V) = 207,0; Pn W = 144,4; In mA = 917,8
-- --
Result: No Hazard;
Fuse-link F1 was opened at once.
Fuse-link current of F1 was 17,9A.
The input power was similar to normal operation and no higher temperature rise occurred.
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short speaker output terminal
Un (V) = 253,0; Pn W = 109,7; In mA = 614,2
-- --
Result: No Hazard;
Fuse-link F1 was opened at once.
Fuse-link F2 was opened at once.
Fuse-link current of F1 was 17,8A.
Fuse-link current of F2 was 17,3A.
The input power was less than normal operation and no higher temperature rise occurred.
Monitored point:
Under fault conditions specified below
DT (K)
Limit dT (K)
Short speaker output terminal
Un (V) = 207,0; Pn W = 94,7; In mA = 62,2
-- --
Result: No Hazard;
Fuse-link F1 was opened at once.
Fuse-link F2 was opened at once.
Fuse-link current of F1 was 13,8A.
Fuse-link current of F2 was 10,6A.
The input power was less than normal operation and no higher temperature rise occurred.