Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
Monitored point: 
Under fault conditions specified below 
dT (K) 
Limit dT (K) 
Short C610 
Un (V) = 253,0; Pn W = 101,8; In mA = 579,7 
-- -- 
Iron core of mains transformer  
3,3 
For reference 
Primary winding of mains transformer 
3,8 
150 
Secondary winding of mains transformer 
3,5 150 
Iron core of standy-by transformer  
20,6 
For reference 
Primary winding of standy-by transformer 
23,1 
150 
Secondary winding standy-by transformer 
23,7 150 
Power cord wire 
8,7 
100 
Secondary lead wire of mains transformer 
7,1 
100 
PCB Surface (near D606) 
26,8 110 
PCB Surface (near D505) 
22,2 110 
Enclosure (metallic/ top/ near power amplifier board) 
12,3 65 
Result: No Hazard; Test time = 30mins 
Components F602 and F603 were burnt at once, and no higher temperature rise occurred. This test was 
repeated 3 times and result was the same. Clause 14.5.4 was considered and complied. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short C606 
Un (V) = 253,0; Pn W = 13,1; In mA = 74,8 
-- -- 
Result: No Hazard; 
Fuse-link F601 was opened at once. 
Fuse-link current of F601 was 2,9A. 
The input power was less than normal operation and no higher temperature rise occurred. 
 
 
Page 58 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short C606 
Un (V) = 207,0; Pn W = 8,2; In mA = 47,1 
-- -- 
Result: No Hazard; 
Fuse-link F601 was opened at once. 
Fuse-link current of F601 was 7,9A. 
The input power was less than normal operation and no higher temperature rise occurred. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short D606 
Un (V) = 253,0; Pn W = 11,4; In mA = 72,5 
-- -- 
Result: No Hazard; 
Fuse-link F601 was opened at once. 
Fuse-link current of F601 was 6,3A. 
The input power was less than normal operation and no higher temperature rise occurred. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short D606 
Un (V) = 207,0; Pn W = 8,3; In mA = 50,2 
-- -- 
Result: No Hazard; 
Fuse-link F601 was opened at once. 
Fuse-link current of F601 was 5,6A. 
The input power was less than normal operation and no higher temperature rise occurred. 
 
 
Page 59 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short C17 
Un (V) = 253,0; Pn W = 111,0; In mA = 621,6 
-- -- 
Result: No Hazard; 
Fuse-link F1 was opened at once. 
Fuse-link F2 was opened at once. 
Fuse-link current of F1 was 16,0A. 
Fuse-link current of F2 was 16,0A. 
The input power was less than normal operation and no higher temperature rise occurred. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short C17 
Un (V) = 207,0; Pn W = 84,7; In mA = 568,9 
-- -- 
Result: No Hazard; 
Fuse-link F1 was opened at once. 
Fuse-link F2 was opened at once. 
Fuse-link current of F1 was 14,7A. 
Fuse-link current of F2 was 14,7A. 
The input power was less than normal operation and no higher temperature rise occurred. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short BR1 (“+” and “AC”) 
Un (V) = 253,0; Pn W = 202,9; In mA = 1064,2 
-- -- 
Result: No Hazard; 
Fuse-link F1 was opened at once. 
Fuse-link current of F1 was 19,4A. 
The input power was similar to normal operation and no higher temperature rise occurred. 
 
 
Page 60 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short BR1 (“+” and “AC”) 
Un (V) = 207,0; Pn W = 144,4; In mA = 917,8 
-- -- 
Result: No Hazard; 
Fuse-link F1 was opened at once. 
Fuse-link current of F1 was 17,9A. 
The input power was similar to normal operation and no higher temperature rise occurred. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short speaker output terminal 
Un (V) = 253,0; Pn W = 109,7; In mA = 614,2 
-- -- 
Result: No Hazard; 
Fuse-link F1 was opened at once. 
Fuse-link F2 was opened at once. 
Fuse-link current of F1 was 17,8A. 
Fuse-link current of F2 was 17,3A. 
The input power was less than normal operation and no higher temperature rise occurred. 
Monitored point: 
Under fault conditions specified below 
DT (K) 
Limit dT (K) 
Short speaker output terminal 
Un (V) = 207,0; Pn W = 94,7; In mA = 62,2 
-- -- 
Result: No Hazard; 
Fuse-link F1 was opened at once. 
Fuse-link F2 was opened at once. 
Fuse-link current of F1 was 13,8A. 
Fuse-link current of F2 was 10,6A. 
The input power was less than normal operation and no higher temperature rise occurred. 