DOWNLOAD Harman Kardon HK 970 (serv.man13) Service Manual ↓ Size: 4.61 MB | Pages: 98 in PDF or view online for FREE

Model
HK 970 (serv.man13)
Pages
98
Size
4.61 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-970-sm13.pdf
Date

Harman Kardon HK 970 (serv.man13) EMC - CB Certificate ▷ View online

 
 
Page 65 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
14 
TABLE: list of critical components and materials (Cont’d) 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Fuse-links 
(FUSE, F1 & F2) 
Suzhou 
Littelfuse OVS 
Ltd. 
618 series 
5
×20mm 
T4AL  250V 
IEC60127 
 
 
Fuse-links 
(F601) 
Suzhou 
Littelfuse OVS 
Ltd. 
218 series 
5
×20mm 
T1AL  250V 
IEC60127 
 
 
Micro-fuses 
(F602 & F603) 
Bel Fuse Inc. 
MS 
1A  125V 
IEC/EN60065 
Tested with 
appliance 
Fuse-link holder 
(FUSE) 
Echo Electric 
Co., Ltd. 
FH-B02 250V 
 
10A 
IEC60127-6 
  
Heat-shrinkable 
tubing that 
enclosed 
terminals of 
mains fuse-link 
(FUSE) 
Han Kyung Co., 
Ltd. 
HST-2 125
°C  600V 
VW-1 
IEC/EN60065 Tested 
with 
appliance 
Plastics material 
of enclosure 
(Front panel) 
Toray Industries 
Inc. 
700 HB75 
IEC60707 
Tested 
with 
appliance 
Power cordset 
(EN type) 
Kenic Electric 
Mfg. Co., Ltd. 
KE-25 
10/16A  250V 
IEC60799 
 
 
  
H05VV-F 
2
×1.0mm
2
 
 
 
Thermal cut-out 
(SW1) 
Texas 
Instruments 
Holland B.V. 
17AM 250V 
 
9A 
IEC60730 
Tubing that 
enclosed 
thermal cut-out 
(SW1) 
Dupont Teijin 
Films U S L P 
AHS1 94VTM-2 
IEC/EN60065 
Tested 
with 
appliance 
Heat-shrinkable 
tubing that 
enclosed power 
switch board 
Jiangsu 
Dasheng Heat 
Shrinkable 
Material Co., 
Ltd. 
DRS-1 125
°C  600V 
VW-1 
IEC/EN60065 Tested 
with 
appliance 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
 
 
Page 66 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
 
Remarks 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
APPENDIX A1 
 
Report No.: HK-R04173361 
 
 
Photo No.:  1 
Title:  Front view 
 
 
Photo No.:  2 
Title:  Rear panel 
Job No.: 0417336 
Job No.: 0417336 
APPENDIX A2 
 
Report No.: HK-R04173361 
 
 
Photo No.:  3 
Title:  Side view 
 
 
Photo No.:  4 
Title:  Side view 
Job No.: 0417336 
Job No.: 0417336 
Page of 98
Display

Click on the first or last page to see other HK 970 (serv.man13) service manuals if exist.