Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate ▷ View online
Page 5 of 51
Report No 248607.
TRF No. IEC60065K
Copy of marking plate
Page 6 of 51
Report No 248607.
TRF No. IEC60065K
Calibration
All instruments used in the tests given in this test report are calibrated and
traceable to national or international standards.
Further information about traceability will be given on request.
traceable to national or international standards.
Further information about traceability will be given on request.
Measurement
uncertainty
uncertainty
Measurement uncertainties are calculated for all instruments and instrument
set-ups given in this report. Calculations are based on the principles given in
the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant
internal Nemko-procedures.
Further information about measurement uncertainties will be given on request.
set-ups given in this report. Calculations are based on the principles given in
the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant
internal Nemko-procedures.
Further information about measurement uncertainties will be given on request.
Evaluation of results
If not explicitly stated otherwise in the standard, the test is passed if the
measured value is equal to or below (above) the limit line, regardless of the
measurement uncertainty. If the measured value is above (below) the limit line,
the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is
within limits agreed by IECEE-CTL.
measured value is equal to or below (above) the limit line, regardless of the
measurement uncertainty. If the measured value is above (below) the limit line,
the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is
within limits agreed by IECEE-CTL.
Test item particulars .................................................. : AV Receiver
Classification of installation and use....................... : Class II apparatus
Supply Connection ..................................................... : Detachable cord with appliance inlet
....................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A (Not Applicable)
- test object does meet the requirement ................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing:
Date of receipt of test item ........................................ : 2013-10-10
Date (s) of performance of tests ............................... : 2013-10-10 to 2013-11-21
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
Yes
Not applicable
Not applicable
When differences exist; they shall be identified in the General product information section.
Page 7 of 51
Report No 248607.
TRF No. IEC60065K
Name and address of factory (ies) .......................... : Factory 1:
Anam Electronics (Dongguan) Co., Ltd.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China
523426.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China
523426.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China
523426.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, GuangDong Province, China
523426.
General product information:
The apparatus under test is AV Receiver of insulation Class II.
The apparatus has amplifier circuits (Right and Left for Speaker1, Right and Left for Speaker2), Tuner
Circuit, Several signal in/out (RCA, NETWORK, Optical, Mini jacks, Phones and USB) terminals,
Bluetooth circuit and Speaker terminals – (See also photos)
Unless otherwise specified, all test condition based on that is connected to speaker 1 and 2 mode.
The apparatus under test is AV Receiver of insulation Class II.
The apparatus has amplifier circuits (Right and Left for Speaker1, Right and Left for Speaker2), Tuner
Circuit, Several signal in/out (RCA, NETWORK, Optical, Mini jacks, Phones and USB) terminals,
Bluetooth circuit and Speaker terminals – (See also photos)
Unless otherwise specified, all test condition based on that is connected to speaker 1 and 2 mode.
Page 8 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3 General
requirements
Safety class of the apparatus .................................. :
Class II apparatus.
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
box
Tested in a wooden test box
according to instructions in
user manual.
(Tested box condition: 30 cm
for top and other sides)
according to instructions in
user manual.
(Tested box condition: 30 cm
for top and other sides)
P
5
Marking and instructions
Comprehensible and easily discernible
On front and rear side of the
enclosure,
enclosure,
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / petroleum
sprit.
sprit.
P
5.1 a)
Identification,
maker ............................................ : Trade mark:
P
b) Model number or type reference ......................... : Model no.
HK3770/230
P
c) Class II symbol if applicable ................................ : Class II symbol according to
IEC 60417-5172 is applied.
P
d) Nature of supply ................................................... : a.c. symbol according to
IEC 60417-5032.is applied.
P
e) Rated supply voltage .......................................... : 220-240 V~
P
f) Mains frequency if safety dependant ................... : 50/60 Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ........................................................................... :
apparatus supplied by supply apparatus for general
use ........................................................................... :
The apparatus is connection
to an a.c. mains supply.
to an a.c. mains supply.
N/A
Measured current or power consumption ............... :
N/A
Deviation % (max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
300 W
P
Measured current or power consumption ............... : Max. 272.8 W
(see appended table 7.1)
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
No television set.
N/A
Deviation % (max 10%) ........................................... : Not exceed the marked value.
P
5.2
a) Earth terminal
Class II apparatus.
N/A