Page 25 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension 
> 450 mm, pass the test of 19.5.1  
No glass surface 
N/A 
19.6 
Wall or ceiling mountings adequate  
No wall or ceiling mountings. 
N/A 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
P 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 
N/A 
 
b) Exemption for small components as defined in 
20.1  
PCB is of flammability class 
V-0, and exception is made 
for small components. 
P 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4  
Electrical components 
comply with flammability 
requirements in clause 14. 
P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
No wires working at 
voltages > 4 kV or leaving 
an internal fire enclosure 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure 
All PCB are of base material 
with flammability category 
V-0 (UL approved), 
See list of critical components. 
P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
No voltage > 400 V (peak) 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
Bobbin (base) of transformers, 
line filters and PFC inductor 
are complying with the relevant 
flammability category in  
Table 21. 
P 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
No such components. 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
Normal operating voltage 
< 4 kV 
N/A 
  
Page 26 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
20.2 Fire 
enclosure 
 
 
N/A 
20.2.1 Potential 
ignition 
sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
No voltage > 4 kV (peak) 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 Marking 
and 
instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
Not intended for outdoor use 
N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1  
No TNV circuits. 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
  
Page 27 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
No electronic flash apparatus. 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
No flash synchroniser. 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency pulse ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
 
 
 
  
Page 28 of 51
Report No 248607.
 
 
TRF No. IEC60065K 
 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF/Stand-by mode of 
the functional switch (W)  ........................................ : 
Less than 0.47 W 
 
 
 
 
 
 
 
Operating Condition / Status 
Standby mode; 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
1 220  50  0.04  0.33 
 
 
2 240  50  0.04  0.43 
 
 
3 220  60  0.05  0.38 
 
 
4 240  60  0.05  0.47 
 
 
 
 
 
 
 
 
 
*), 1khz input signal with maximum non-clipped output mode with loaded 5 V dc/2.1 A through  
USB (Version 2.0) terminal (connected 8 ohms x 2 loads at SPEAKER 1 terminals); 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
5 198  50  4.59  541.2 
34.0 x 2 ch. (Speaker 1) 144.5 x 2 ch. (Speaker 1)
6 264  50  3.15  523.2 
7 198  60  4.15  534.2 
8 264  60  2.99  520.7 
 
 
 
 
 
 
 
**), 1khz input signal with maximum non-clipped output mode with loaded 5 V dc/2.1 A through 
USB (Version 2.0) terminal (connected 8 ohms x 4 loads at SPEAKER 1 and 2 terminals); 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) rms 
Pout (W) 
9 198 50  4.63  545.2 
23.3 x 2 ch. (Speaker 1)
23.3 x 2 ch. (Speaker 2)
67.9 x 2 ch. (Speaker 1) 
67.9 x 2 ch. (Speaker 2) 
10 264  50  3.22  533.5 
11 198  60  4.25  540.7 
12 264  60  3.04  529.8 
 
 
 
 
 
 
 
Measured at,   *) HIGH mode   **) MID mode of the transformer output, TF93  – see summary of  
testing for details) 
 
Page of 93