Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate ▷ View online
Page 17 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes, see below.
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ……:
CY91, CY92, CY93, CY94 and
CY95 certified according to
IEC 60384-14.
CY95 certified according to
IEC 60384-14.
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ……:
CX91 and CX92 certified
according to IEC 60384-14.
according to IEC 60384-14.
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such capacitors.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
Several E. cap. exceeding
volume 1750 mm³, but metal
cases.
volume 1750 mm³, but metal
cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
Several E. cap. exceeding
volume 1750 mm³, but metal
cases.
volume 1750 mm³, but metal
cases.
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ....................................................................... :
metal ....................................................................... :
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5.
according to 14.3.3, 14.3.4
and 14.3.5.
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Adequate marking applied.
Mfr, ID and type no.
Mfr, ID and type no.
P
Transformers and inductors separately approved .:
No
N/A
14.3.2
General
Isolating transformers.
P
Insulation material complies with clause 20.1.4
Considered. The insulation
material of isolating transf.
complies with flammability
category of Table 21.
material of isolating transf.
complies with flammability
category of Table 21.
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table 13)
P
14.3.3.2
Transformers meet the constructional requirements (see appended table 14.3.3)
P
14.3.4
Separation between windings
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ..............................:
between hazardous live parts and accessible parts
(double or reinforced insulation) ..............................:
Double or reinforced insulation
between primary and
secondary windings
according to clause 8.8.
(see appended table 14.3.3)
between primary and
secondary windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm
>0.4 mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Transformers are evaluate
with class II construction,
with class II construction,
N/A
Page 18 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.4.3
Separating transformers with at least basic insulation Windings of class II
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
> 0,4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal cut-outs and fuse.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied (thermal cut-outs and
fuse)
See appended table, list of
critical components.
applied (thermal cut-outs and
fuse)
See appended table, list of
critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
TS92 thermal cut-out is
approved component
according to IEC 60730-1.
See appended table, list of
critical components.
approved component
according to IEC 60730-1.
See appended table, list of
critical components.
P
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
No thermal links
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal device re-settable
by soldering.
by soldering.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuse is approved according
to IEC 60127.
See appended table, list of
critical components.
to IEC 60127.
See appended table, list of
critical components.
P
Page 19 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Marked on PCB adjacent to
fuse as;
F901: T 6.3A H 250V
fuse as;
F901: T 6.3A H 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No possible to connect fuses
in parallel.
in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC thermistors comply with IEC 60730-1:2007
PTC thermistor, F1301 for
USB port, comply with
IEC 60730-1
USB port, comply with
IEC 60730-1
P
PTC devices (15 W) category V-1 or better
<15 W
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
Only standard fuse and
protector used.
protector used.
N/A
14.6
Switches
No mains switch.
N/A
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
No mains socket-outlets
N/A
Page 20 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.7
Safety interlocks
No safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950-1
N/A
14.8
Voltage setting devices and the like
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
No AC motors.
Brushless DC FAN motor only.
Brushless DC FAN motor only.
P
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
Only DC supplied
N/A
14.9.2
Not adversely affected by oil or grease etc.
The motor for fans are not
adversely affected by oil or
grease or other substances.
adversely affected by oil or
grease or other substances.
P
14.9.3
Protection against moving parts
The fans are placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N/A
14.10 Batteries
No
batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
Optocouplers are approved
components.
External creepage/clearance
distances are min. 5.0 mm.
Internal creepage/clearance
distances are min 4.0 mm, or
thermal cycling test is covered
by SEMKO
DTI: Min. 0.4 mm.
See appended table, list of
critical components.
components.
External creepage/clearance
distances are min. 5.0 mm.
Internal creepage/clearance
distances are min 4.0 mm, or
thermal cycling test is covered
by SEMKO
DTI: Min. 0.4 mm.
See appended table, list of
critical components.
P
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A
b) Comply with IEC 60747-5-5:2007
N/A
Alternative to a) and b) optocoupler comply with 13.8
N/A
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A