Page 17 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14.2 
Capacitors and RC units  
 
P 
 
Capacitors separately approved  : 
Yes, see below. 
P 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
CY91, CY92, CY93, CY94 and 
CY95 certified according to 
IEC 60384-14. 
P 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
CX91 and CX92 certified 
according to IEC 60384-14. 
P 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... : 
No such capacitors. 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better  ................. : 
Several E. cap. exceeding 
volume 1750 mm³, but metal 
cases. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................ : 
Several E. cap. exceeding 
volume 1750 mm³, but metal 
cases. 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal  ....................................................................... : 
 
N/A 
14.3 
Inductors and windings  
 
P 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
Transformers evaluated 
according to 14.3.3, 14.3.4 
and 14.3.5. 
P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  .............................. : 
Adequate marking applied. 
Mfr, ID and type no. 
P 
 
Transformers and inductors separately approved  .: 
No 
N/A 
14.3.2 
General  
Isolating transformers. 
P 
 
Insulation material complies with clause 20.1.4  
Considered. The insulation 
material of isolating transf. 
complies with flammability 
category of Table 21. 
P 
14.3.3 
Constructional requirements  
 
P 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
(see appended table 13) 
P 
14.3.3.2 
Transformers meet the constructional requirements  (see appended table 14.3.3) 
P 
14.3.4 
Separation between windings 
 
P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) ..............................: 
Double or reinforced insulation  
between primary and 
secondary windings 
according to clause 8.8. 
(see appended table 14.3.3) 
P 
 
Coil formers and partition walls > 0,4 mm  
>0.4 mm 
P 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
Transformers are evaluate 
with class II construction, 
N/A 
  
Page 18 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14.3.4.3 
Separating transformers with at least basic insulation Windings of class II 
construction used. 
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 
P 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
Double or reinforced insulation  
between hazardous live 
windings and accessible 
conductive parts. 
P 
 
Coil formers and partition walls > 0,4 mm  
> 0,4 mm 
P 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
Windings of class II 
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
No high-voltage components. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 Protective 
devices 
 
 
P 
 
Protective devices used within their ratings  
Thermal cut-outs and fuse. 
P 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Certified protective devices 
applied (thermal cut-outs and 
fuse) 
See appended table, list of 
critical components. 
P 
14.5.1.1 
a) Thermal cut-outs separately approved  
TS92 thermal cut-out is 
approved component 
according to IEC 60730-1. 
See appended table, list of 
critical components. 
P 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
No thermal links 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No thermal device re-settable 
by soldering. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
Fuse is approved according 
to IEC 60127. 
See appended table, list of 
critical components. 
P 
  
Page 19 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
Marked on PCB adjacent to 
fuse as; 
F901: T 6.3A H 250V 
P 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : 
No possible to connect fuses 
in parallel. 
P 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... : 
No replacement of fuse 
possible by hand. 
P 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
PTC thermistor, F1301 for 
USB port, comply with  
IEC 60730-1 
P 
 
PTC devices (15 W) category V-1 or better  
<15 W 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
Only standard fuse and 
protector used. 
N/A 
14.6 
Switches  
No mains switch. 
N/A 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
 
N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 
N/A 
 
Switch controlling < 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 
N/A 
 
Socket outlet current marking correct  
No mains socket-outlets 
N/A 
  
Page 20 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14.7 
Safety interlocks  
No safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 
Motors 
No AC motors. 
Brushless DC FAN motor only. 
P 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
Only DC supplied 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
The motor for fans are not 
adversely affected by oil or 
grease or other substances. 
P 
14.9.3 
Protection against moving parts  
The fans are placed inside the 
unit. No access. 
P 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 
N/A 
14.10 Batteries 
No 
batteries 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
Optocouplers are approved 
components. 
 
External creepage/clearance 
distances are min. 5.0 mm. 
Internal creepage/clearance 
distances are min 4.0 mm, or 
thermal cycling test is covered 
by SEMKO 
DTI: Min. 0.4 mm. 
See appended table, list of 
critical components. 
P 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
 
b) Comply with IEC 60747-5-5:2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8  
N/A 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 