Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate ▷ View online
Page 13 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltage >1000 V ac or
>1500 V dc
>1500 V dc
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage
>35 V ac, see below.
>35 V ac, see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................ :
using the network in annex D ................................ :
U1: Max. 0.68 V (peak)
U2: Max. 0.31 V (peak)
(Tested at 264 V/ 60 Hz)
U2: Max. 0.31 V (peak)
(Tested at 264 V/ 60 Hz)
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60 V – 150 kV.
terminal with stored voltages
between 60 V – 150 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of a terminal
with stored voltages exceeding
15 kV.
with stored voltages exceeding
15 kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts.
live parts.
P
9.1.2
No hazardous live shafts of knobs, handles or levers No live shafts of knobs,
handles or levers.
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
32 V dc after 2 s,
Bleeder resistor provided.
See clause 14.1 b), and
appended table, list of critical
components.
Bleeder resistor provided.
See clause 14.1 b), and
appended table, list of critical
components.
P
If C is not greater than 0,1 μF no test needed
>0,1 μF
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger results
in no hazard.
in no hazard.
P
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Tested 100 N result in no
hazard.
hazard.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N/A
Page 14 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Basic: >2.6 MΩ,
Reinforced: >5.2 MΩ after
surge test.
Reinforced: >5.2 MΩ after
surge test.
P
10.2
Humidity treatment 48 h or 120 h .......................... :
Performed for 120 h at temp.
40 ºC and humidity 93 %.
40 ºC and humidity 93 %.
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
(see appended table 11.2)
P
Flames extinguish within 10 seconds
No flames.
P
No hazard from softening solder
No softening solder.
P
Soldered terminations not used as protective
mechanism
mechanism
No soldered terminations.
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table 11.2)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
No exceeding the limits of
Table 3.
Table 3.
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
No area where temperature
exceeds 100 K above limits.
exceeds 100 K above limits.
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
No area where temperature
exceeds 300 K above limits.
exceeds 300 K above limits.
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
No conductors are
interrupted/peeled/loosened
during fault conditions.
interrupted/peeled/loosened
during fault conditions.
N/A
Page 15 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Class I protective earthing maintained
Class II apparatus
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
(see appended table 11.2)
P
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg
Mass: 5.0 kg
N/A
12.1.2
Vibration test
Assessed to be
satisfactory constructed.
satisfactory constructed.
P
12.1.3
Impact hammer test
No damage in the sense of
this standard.
this standard.
P
Steel ball test
No damage in the sense of
this standard.
this standard.
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg No portable apparatus.
N/A
12.1.5
Thermoplastic enclosures stress relief test
No risk of shrinkage or
distortion on enclosure.
distortion on enclosure.
P
12.2
Fixing of knobs, push buttons, keys and levers
Normal use will not impair
the protection against
electric shock.
the protection against
electric shock.
P
12.3
Remote controls with hazardous live parts
No remote control containing
hazardous live parts.
hazardous live parts.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation
No such antenna coaxial
sockets.
sockets.
N/A
12.6
Telescoping or rod antennas construction
No telescoping or rod
antennas.
antennas.
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See 13.3
P
Creepage distances in accordance with 13.4
See 13.4
P
13.2
Determination of working voltage
Conventional transformer
used. Upper rated supply
voltage. (240 V) applied in
determining the working
voltage
used. Upper rated supply
voltage. (240 V) applied in
determining the working
voltage
P
13.3
Clearances
2 N for internal parts and 30 N
for enclosure are considered
when determining clearances.
for enclosure are considered
when determining clearances.
P
13.3.1 General
Considered.
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............ :
with table 8 and, where applicable, table 9 ............ :
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages.
voltages.
N/A
Page 16 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.3.4
Measurement of transient voltages
No measurement of transient
voltages.
voltages.
N/A
13.4
Creepage distances
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values
values
Not applicable.
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards.
circuit boards.
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
Jointed insulation not applied.
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
No such part used.
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Approved optocouplers.
See appended table, list of
critical components.
See appended table, list of
critical components.
P
14 Components
14.1 Resistors
P
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Bleeder resistor, RX93.
(Connected between Live and
Neutral after mains fuse,
certified component by VDE)
See appended table, list of
critical components.
(Connected between Live and
Neutral after mains fuse,
certified component by VDE)
See appended table, list of
critical components.
P
Resistors
separately approved .............................. :
RX93.
See appended table, list of
critical components.
See appended table, list of
critical components.
P