Page 21 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14.12 
Surge suppression varistors  
 
P 
 
Comply with IEC 61051-2  
Varistors, VT91 and VT92 
comply with IEC 61051-2. 
VT91 is connected across 
mains poles. 
P 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
A certified varistor used. 
N/A 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved cord set and 
appliance inlet provided. 
See appended table, list of 
critical components, and 
summary of testing. 
P 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
No mains socket outlets 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
No mains socket outlets 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
See below. 
P 
 
No risk of insertion in mains socket-outlets  
Only RCA, Antenna, Network, 
Optical and mini jacks 
terminals used. 
Banana plug type speaker 
terminal also used, but they 
are accepted due to below 
note. 
 
Note) 
Banana plug type speaker 
terminals are blocked in their 
axial holes to prevent use of 
plugs that can make 
permanent contact with a 
mains socket outlet. 
P 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
No sockets indicated with 
the symbol. 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
Not adaptors used. 
N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II equipment 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
  
Page 22 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  .................. :   
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
Appliance inlet applied. 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board   
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 
N/A 
 
Wire secured by additional means to the  
conductor   
No screws and nuts clamping 
conductors used. 
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
No such terminal used. 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16   
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 
N/A 
15.4 
Devices forming a part of the mains plug  
No devices forming a part of 
the mains plug. 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
  
Page 23 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ........................................................... : 
Sheathed PVC cord  
complying with IEC 60227. 
 
See appended table, list of 
critical components. 
P 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Class II equipment 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
The cord is min. 0.75 mm
2
 
within the current rating. 
 
See appended table, list of 
critical components. 
P 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
No interconnecting cords. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2) 
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
No interconnecting cords. 
N/A 
16.5 
Adequate strain relief on external flexible cords  
Appliance inlet provided. 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
Class II equipment 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
Appliance inlet provided. 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
The apparatus is not a 
transportable musical 
instrument and amplifier. 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 
N/A 
 
  
Page 24 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
17 
Electrical connections and mechanical fixings 
 
17.1 
Torque test to table 20  
See below 
P 
 
- screws into metal: 5 times  
(see appended table 17.1) 
P 
 
- screws into non-metallic material: 10 times  
(see appended table 17.1) 
P 
17.2 
Correct introduction into female threads in non-
metallic material  
Correct introduction of screws 
into non-metallic material for 
top cover. 
P 
17.3 
Cover fixing screws: captive  
Captivity not necessary 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
Tested with screw with 
10 times diameter. 
P 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
Loosening is sufficiently 
prevented. 
P 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
No contact pressure 
transmitted through insulating 
material. 
P 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder  
No such screw terminals. 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
No cover fixing devices 
other than screws. 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
No detachable legs or stands 
provided. 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected  
Connections comply, 
checked by inspection. 
P 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
18.1 
Picture tube separately approved to IEC 61965  ... :  No picture tube used. 
N/A 
 
Picture tube separately approved to 18.2  .............. : 
 
N/A 
18.2 
Non-intrinsically protected tubes tested to 18.2 
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 7 kg  ................. : 
Mass: 5.0 kg 
 
 
Apparatus intended to be fastened in place – 
suitable instructions  ................................................ : 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
 
N/A 
19.2 
100 N force applied vertically downwards  
 
N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability  
Mass: < 25 kg or < 1 m 
N/A 
19.4 
Edges or corners not hazardous  
There are no hazardous 
edges or corners when the 
apparatus is operating in 
normal position. 
P 