Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate ▷ View online
Page 5 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
1 GENERAL
P
1.5 Components
P
1.5.1 General
P
Comply with IEC 60950 or relevant component
standard
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
P
1.5.3 Thermal
controls
No such device within the EUT
N/A
1.5.4 Transformers
(see also Annex C)
P
1.5.5 Interconnecting
cables
P
1.5.6
Capacitors in primary circuits ........................... : X2 capacitor, CX1;
Y1 capacitor, CY2, CY3,
considered as X1 capacitor
(see appended table 1.5.1)
considered as X1 capacitor
(see appended table 1.5.1)
P
1.5.7
Double insulation or reinforced insulation bridged
by components
by components
Double or reinforced insulation
between primary and
secondary bridged by Y1
capacitor, CY1 (see appended
table 1.5.1)
between primary and
secondary bridged by Y1
capacitor, CY1 (see appended
table 1.5.1)
P
1.5.7.1 General
P
1.5.7.2 Bridging
capacitors
Approved Y1 capacitor, CY1
P
1.5.7.3 Bridging
resistors
N/A
1.5.7.4 Accessible
parts
See clause 2.4
P
1.5.8
Components in equipment for IT power systems P
1.6 Power
interface
P
1.6.1
AC power distribution systems
TN, TT and IT (Only for
Norway)
Norway)
P
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The EUT is not hand-held
equipment
equipment
N/A
1.6.4 Neutral
conductor
P
1.7
Marking and instructions
P
1.7.1 Power
rating
P
Rated voltage(s) or voltage range(s) (V) .......... : 100 – 240 V ~
P
Page 6 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
Symbol for nature of supply, for d.c. only ........... : The EUT is supplied by AC
mains
N/A
Rated frequency or rated frequency range (Hz) : 50/60 Hz
P
Rated
current
(mA or A) .................................... : 2 A
P
Manufacturer’s name or trademark or
identification mark ............................................. :
identification mark ............................................. :
LEI / TECTROL (logo)
P
Type/model or type reference............................. : NU60-9240***-I3, P
Symbol for Class II equipment only .................. :
P
Other
symbols ................................................... : Symbols are used according to
IEC 60417-1
P
Certification marks ............................................. :
N/A
1.7.2 Safety
instructions
The English “I. T. E. Power
supply” will be provided with the
unit
supply” will be provided with the
unit
P
1.7.3
Short duty cycles
The EUT is continuous
operating type
operating type
N/A
1.7.4 Supply
voltage adjustment ................................ : Only one power supply voltage
range
N/A
1.7.5 Power
outlets
on the equipment ....................... : No such component within the
EUT
N/A
1.7.6 Fuse
identification ............................................. : T 3.15 AH, 250 V
P
1.7.7 Wiring
terminals
Appliance inlet used
N/A
1.7.7.1
Protective earthing and bonding terminals ....... : Class II equipment
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
P
1.7.8.1 Identification,
location and marking ................... : No controls and switches within
the EUT
N/A
1.7.8.2 Colours ............................................................. : No safety relevant indicators,
One indication LEDs (green
colour) beside output side are
provided for output status
colour) beside output side are
provided for output status
P
1.7.8.3 Symbols
according to IEC 60417 ....................... : N/A
1.7.8.4 Markings
using figures ..................................... : No figures used as marking
N/A
1.7.9
Isolation of multiple power sources ................... : Only one power supply
N/A
1.7.10
IT power distribution systems
Only for Norway
P
Page 7 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
1.7.11
Thermostats and other regulating devices
No such device within the EUT
N/A
1.7.12
Language .......................................................... : English and local language to
each country that would be
marked
marked
⎯
1.7.13 Durability
P
1.7.14 Removable
parts
No such parts
N/A
1.7.15 Replaceable
batteries
No battery within the EUT
N/A
Language............................................................ :
⎯
1.7.16 Operator
access with a tool ................................ : No such area
N/A
1.7.17
Equipment for restricted access locations.......... : The EUT is not such type
N/A
Page 8 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
See comment below
P
Test by inspection ............................................. : The concerned hazardous
parts are not accessible
P
Test with test finger ........................................... : The concerned hazardous
parts are not accessible
P
Test
with
test pin ............................................... : Hazardous live parts are not
accessible
P
Test
with
test probe .......................................... : No TNV circuit within the EUT
N/A
2.1.1.2 Battery
compartments ....................................... : No battery compartment within
the EUT
N/A
2.1.1.3
Access to ELV wiring
No ELV circuit within the EUT
N/A
Working voltage (V); minimum distance (mm)
through insulation
through insulation
⎯
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5 Energy hazards ................................................. : (see appended table 2.1.1.5)
P
2.1.1.6 Manual
controls
No such device
N/A
2.1.1.7
Discharge of capacitors in equipment
P
Time-constant
(s);
measured voltage (V) ........... : 28 V peak at 1 s,
37% Vp (126 Vpeak) at 296 ms
⎯
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2 SELV
circuits
P
2.2.1 General
requirements
P
2.2.2
Voltages under normal conditions (V) ................ : Measured: Max. 25.6 Vdc after
D3 (104 Vpeak after T1 (A-B),
not SELV)
not SELV)
P
2.2.3
Voltages under fault conditions (V) .................... : Measured: Max. 35.6 Vpeak
(open U2 pin 3)
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
P
2.2.3.2 Separation
by
earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits .......: Connecting to LCC circuit
P
Click on the first or last page to see other GO PLAY MICRO (serv.man4) service manuals if exist.