Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate ▷ View online
Page 33 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
Optocoupler
(U2)
Lite-On
Technology
Corporation
LTV-817
Int. CR / Ext. Cr / Dti:
>4 / 8 / >0,4 mm
EN 60950:
2000
VDE
Optocoupler
(U2),
alternative
NEC Compound
Semiconductor
Devices Ltd.
PS2561-1
Int. CR / Ext. Cr / Dti:
>4 / ≥7 / >0,4 mm
DIN VDE 0884:
1987
VDE
Optocoupler
(U2),
alternative
Sharp Corporation
Electronic
Components
Group
PC817,
PC120,
PC123
Int. CR / Ext. Cr / Dti:
>4 / >8 / >0,4 mm
VDE 0884:
2002
VDE
Optocoupler
(U2),
alternative
Toshiba
Corporation
Electronic Devices
Sales & Marketing
Group
TLP421
Int. CR / Ext. Cr / Dti:
>4 / >8 / 0,4 mm
EN 60950:
2000
Semko
Optocoupler
(U2),
alternative
Vishay
Semiconductor
GmbH
SFH 615AA
Int. CR / Ext. Cr / Dti:
4.9 / 8.2 / 0.5 mm
DIN VDE 0884:
1992
VDE
Ripple
capacitor (C2)
Various
Various
Min. 400 V, 105 °C,
max. 120 µF
Applicable parts
of IEC 60950-1
Tested in
appliance
Bridging
rectifier (BD1)
Various
Various
Min. 600 V, 4 A
Applicable parts
of IEC 60950-1
Tested in
appliance
MOSFET (Q1) Various
Various
Min. 600 V, 5.2 A
Applicable parts
of IEC 60950-1
Tested in
appliance
Bleeding
resistor (R1A,
R1B)
Various
Various
Max. 510 kΩ, ¼ W
Applicable parts
of IEC 60950-1
Tested in
appliance
NTC (NTC1)
Various
Various
Max. 2.5 Ω, 5 A
Applicable parts
of IEC 60950-1
Tested in
appliance
Rectifier (D8)
Various
Various
Min. 200 V, 10 A
Applicable parts
of IEC 60950-1
Tested in
appliance
Output cord
Various
Various
Min. 300 V, 105 °C,
18 AWG
Applicable parts
of IEC 60950-1
Tested in
appliance
Insulation tape Various
Various
Min. 130 °C
Applicable parts
of IEC 60950-1
Tested in
appliance
Chock (L1)
Leader Electronics
Inc.
LS-YC00106-
***
note
Min. 130 °C
Applicable parts
of IEC 60950-1
Tested in
appliance
Chock (L3)
Leader Electronics
Inc.
LS-13062-***
note
Min. 130 °C
Applicable parts
of IEC 60950-1
Tested in
appliance
Chock (L4)
Leader Electronics
Inc.
LS-14433-***
note
Min. 130 °C
Applicable parts
of IEC 60950-1
Tested in
appliance
Transformer parts list:
Transformer
(T1)
Leader Electronics
Inc.
LS-B2285-***
note
Class E
Applicable parts
of IEC 60950-1
Tested in
appliance
Magnet wire
(PRI.)
Various Various
Min.
130
o
C Applicable
parts
of IEC 60950-1
Tested in
appliance
Page 34 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
Triple
insulation wire
(SEC.)
Great Leoflon
Industrial Co., Ltd.
TRW(B) Min.
130
o
C EN
60950:
2000
VDE
Triple
insulation wire
(SEC.)
alterative
The Furukawa
Electric Co., Ltd.
TEX-B, TEX-E Min. 120
o
C EN
60950:
2000
VDE
Triple
insulation wire
(SEC.)
alterative
Totoku Electric
Co., Ltd.
TIW-E, TIW-2,
TIW-3
Min. 120
o
C EN
60950:
2000
TüV
Rheinland
Triple
insulation wire
(SEC.)
alterative
Daikyo Electronics
Wire Co., Ltd.
DTM-B Min.
130
o
C EN
60950:
2000
TüV
Rheinland
Plastic material list:
Plastic
Enclosure
GE Plastics
Americas
940(f1),
945(GG),
SE1, SE1X
SE100,
SE100X
Min. V-1, Min. 95
o
C,
Min. 2.5 mm
thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
Plastic
Enclosure,
alternative
Chi Mei
Corporation
PA-765A
Min. V-1, Min. 85
o
C,
Min. 2.5 mm
thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
PCB
Yue Wah Circuits
Co., Ltd.
4A V-0,
130
o
C, Min. 1.6
mm thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
PCB,
alternative
Various Various
V-1,
130
o
C, Min. 1.6
mm thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
Bobbin of
transformer
Chang Chun
Plastic Co., Ltd.
T375J V-0,
150
o
C, Min. 0.8
mm thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
Bobbin of
transformer,
alternative
Sumitomo Bakelite
Co., Ltd.
PM-9820,
PM-9630
V-0, 150
o
C, Min. 1.0
mm thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
Bobbin of
transformer,
alternative
Hitachi Chemical
Co., Ltd.
CP-J-8800 V-0,
150
o
C, Min. 1.0
mm thickness
Applicable parts
of IEC 60950-1
Tested in
appliance
Heat
shrinkable tube
Various
Various
Min. 300 V, 125
o
C,
VW-1
Applicable parts
of IEC 60950-1
Tested in
appliance
1) An asterisk indicates a mark which assures the agreed level of surveillance.
2) All the plastic material mentioned are checked and found to be acceptable for using in this product.
Checking date: Same as this report issued data, see also page 1.
3) Note: The 1
st
to 3
rd
“*” may be “0-9”, “A-Z”, ”-” or blank only to indicate the marketing purpose.
Page 35 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
1.6.2
TABLE: electrical data (in normal conditions)
P
Fuse
Irated (A)
U(V)
P(W)
I(A)
Ifuse(A) Condition /status
F1
- 90
(50Hz/60Hz)
72.1/71.5 1.29/1.27 1.29/1.27 Maximum rated output load
F1
2 100
(50Hz/60Hz)
71.0/70.9 1.15/1.10 1.15/1.10 Maximum rated output load
F1
2 240
(50Hz/60Hz)
70.0/70.1 0.55/0.54 0.55/0.54 Maximum rated output load
F1
- 254.4
(50Hz/60Hz)
70.0/69.9 0.52/0.51 0.52/0.51 Maximum rated output load
F1
- 264
(50Hz/60Hz)
69.9/69.8 0.53/0.50 0.53/0.50 Maximum rated output load
2.1.1.5
TABLE: energy hazards measurements
P
Measured
between
Max. V
(Uoc)
Max. A
(Isc)
V of Max.
power
A of Max.
power
Max. power
Bridged by
test finger
Output terminal
25.6 Vdc
3.7 A
23.5 Vdc
3.7 A
86.3 VA
No
2.10.3 and
2.10.4
2.10.4
TABLE: clearance and creepage distance measurements
P
clearance cl and creepage
distance dcr at/of:
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
PCB solder side
L to N before fusing resistor (RF1)
(FI)
(FI)
340 240
1.5
7.4
2.5
9.2
Primary and secondary (two side
of CY1) (RI)
of CY1) (RI)
550 240
4.4
7.0
5.0
7.0
Primary and secondary (two side
of U2) (RI)
of U2) (RI)
550 240
4.4
5.7
5.0
9.0
Primary traces (F1) to user
accessible parts (RI)
accessible parts (RI)
550 240
4.4
9.1
5.0
9.1
PCB component side
L and N before fusible resistor
(RF1) (FI)
(RF1) (FI)
340 240
1.5
9.2
2.5
9.2
Primary and secondary (two side
of CY1) (RI)
of CY1) (RI)
550 240
4.4
7.3
5.0
7.3
Primary and secondary (two side
of U2) (RI)
of U2) (RI)
550 240
4.4
6.5
5.0
6.5
Primary components (BD1) to
secondary components (HS2) (RI)
secondary components (HS2) (RI)
550 240
4.4
10.2
5.0
10.2
Primary components (HS1) to user
accessible parts (RI)
accessible parts (RI)
550 240
4.4
5.1
5.0
5.1
Secondary components (U3) to
primary components (HS1) (RI)
primary components (HS1) (RI)
550 240
4.4
9.4
5.0
9.4
Page 36 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
2.10.3 and
2.10.4
2.10.4
TABLE: clearance and creepage distance measurements
P
clearance cl and creepage
distance dcr at/of:
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
Secondary component L4 to core
3)
of transformer (RI)
550 240
4.4
5.5
5.0
5.5
Secondary component C6&C7 to
core
core
3)
of transformer (RI)
550 240
4.4
6.9
5.0
6.9
Secondary component C8&L3 to
core
core
3)
of transformer (RI)
550 240
4.4
8.1
5.0
8.1
Transformer (T1)
Secondary to core
3)
(RI)
550 240
4.4
5.8
5.0
5.8
Primary to secondary (RI)
550 240
4.4
8.8
5.0
8.8
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
2) A force of 10 N is applied to the internal components and 250 N is applied to the enclosure for
measuring.
3) The core of transformer (T1) is considered as primary component, the triple insulation wire are used as
secondary winding of transformer.
4) The required dcr was consider 250 Vrms.
Click on the first or last page to see other GO PLAY MICRO (serv.man4) service manuals if exist.