Page 33 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
Optocoupler 
(U2) 
Lite-On 
Technology 
Corporation 
LTV-817 
Int. CR / Ext. Cr / Dti: 
>4 / 8 / >0,4 mm 
EN 60950: 
2000 
VDE 
Optocoupler 
(U2), 
alternative 
NEC Compound 
Semiconductor 
Devices Ltd. 
PS2561-1 
Int. CR / Ext. Cr / Dti: 
>4 / ≥7 / >0,4 mm 
DIN VDE 0884: 
1987 
VDE 
Optocoupler 
(U2), 
alternative 
Sharp Corporation 
Electronic 
Components 
Group 
PC817, 
PC120, 
PC123 
Int. CR / Ext. Cr / Dti: 
>4 / >8 / >0,4 mm 
VDE 0884: 
2002 
VDE 
Optocoupler 
(U2), 
alternative 
Toshiba 
Corporation 
Electronic Devices 
Sales & Marketing 
Group 
TLP421 
Int. CR / Ext. Cr / Dti: 
>4 / >8 / 0,4 mm 
EN 60950: 
2000 
Semko 
Optocoupler 
(U2), 
alternative 
Vishay 
Semiconductor 
GmbH 
SFH 615AA 
Int. CR / Ext. Cr / Dti: 
4.9 / 8.2 / 0.5 mm 
DIN VDE 0884: 
1992 
VDE 
Ripple 
capacitor (C2) 
Various 
Various 
Min. 400 V, 105 °C, 
max. 120 µF 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Bridging 
rectifier (BD1) 
Various 
Various 
Min. 600 V, 4 A 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
MOSFET (Q1)  Various 
Various 
Min. 600 V, 5.2 A 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Bleeding 
resistor (R1A, 
R1B) 
Various 
Various 
Max. 510 kΩ, ¼ W 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
NTC (NTC1) 
Various 
Various 
Max. 2.5 Ω, 5 A 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Rectifier (D8) 
Various 
Various 
Min. 200 V, 10 A 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Output cord 
Various 
Various 
Min. 300 V, 105 °C, 
18 AWG 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Insulation tape  Various 
Various 
Min. 130 °C 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Chock (L1) 
Leader Electronics 
Inc. 
LS-YC00106-
*** 
note 
Min. 130 °C 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Chock (L3) 
Leader Electronics 
Inc. 
LS-13062-*** 
note
 
Min. 130 °C 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Chock (L4) 
Leader Electronics 
Inc. 
LS-14433-*** 
note
 
Min. 130 °C 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Transformer parts list: 
Transformer 
(T1) 
Leader Electronics 
Inc. 
LS-B2285-*** 
note
 
Class E 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Magnet wire 
(PRI.) 
Various Various 
Min. 
130
 o
C Applicable 
parts 
of IEC 60950-1 
Tested in 
appliance 
 
 
 
 
Page 34 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
Triple 
insulation wire 
(SEC.) 
Great Leoflon 
Industrial Co., Ltd. 
TRW(B) Min. 
130 
o
C EN 
60950: 
2000 
VDE 
Triple 
insulation wire 
(SEC.) 
alterative 
The Furukawa 
Electric Co., Ltd. 
TEX-B, TEX-E Min. 120 
o
C EN 
60950: 
2000 
VDE 
Triple 
insulation wire 
(SEC.) 
alterative 
Totoku Electric 
Co., Ltd. 
TIW-E, TIW-2, 
TIW-3 
Min. 120 
o
C EN 
60950: 
2000 
TüV 
Rheinland 
Triple 
insulation wire 
(SEC.) 
alterative 
Daikyo Electronics 
Wire Co., Ltd. 
DTM-B Min. 
130 
o
C EN 
60950: 
2000 
TüV 
Rheinland 
Plastic material list: 
Plastic 
Enclosure  
GE Plastics 
Americas 
940(f1), 
945(GG), 
SE1, SE1X 
SE100, 
SE100X 
Min. V-1, Min. 95
 o
C, 
Min. 2.5 mm 
thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Plastic 
Enclosure, 
alternative 
Chi Mei 
Corporation 
PA-765A 
Min. V-1, Min. 85
 o
C, 
Min. 2.5 mm 
thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
PCB 
Yue Wah Circuits 
Co., Ltd. 
4A V-0, 
130 
o
C, Min. 1.6 
mm thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
PCB, 
alternative 
Various Various 
V-1, 
130 
o
C, Min. 1.6 
mm thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Bobbin of 
transformer 
Chang Chun 
Plastic Co., Ltd. 
T375J V-0, 
150
 o
C, Min. 0.8 
mm thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Bobbin of 
transformer, 
alternative 
Sumitomo Bakelite 
Co., Ltd. 
PM-9820,  
PM-9630 
V-0, 150
 o
C, Min. 1.0 
mm thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Bobbin of 
transformer, 
alternative 
Hitachi Chemical 
Co., Ltd. 
CP-J-8800 V-0, 
150
 o
C, Min. 1.0 
mm thickness 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
Heat 
shrinkable tube 
Various 
Various 
Min. 300 V, 125 
o
C, 
VW-1 
Applicable parts 
of IEC 60950-1 
Tested in 
appliance 
1)  An asterisk indicates a mark which assures the agreed level of surveillance. 
2)  All the plastic material mentioned are checked and found to be acceptable for using in this product. 
Checking date: Same as this report issued data, see also page 1. 
3)  Note: The 1
st
 to 3
rd
 “*” may be “0-9”, “A-Z”, ”-” or blank only to indicate the marketing purpose. 
 
 
 
 
Page 35 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
 
1.6.2 
TABLE: electrical data (in normal conditions) 
Fuse 
Irated (A) 
U(V) 
P(W) 
I(A) 
Ifuse(A)  Condition /status 
F1 
- 90 
(50Hz/60Hz) 
72.1/71.5 1.29/1.27 1.29/1.27 Maximum rated output load
F1 
2 100 
(50Hz/60Hz) 
71.0/70.9 1.15/1.10 1.15/1.10 Maximum rated output load
F1 
2 240 
(50Hz/60Hz) 
70.0/70.1 0.55/0.54 0.55/0.54 Maximum rated output load
F1 
- 254.4 
(50Hz/60Hz) 
70.0/69.9 0.52/0.51 0.52/0.51 Maximum rated output load
F1 
- 264 
(50Hz/60Hz) 
69.9/69.8 0.53/0.50 0.53/0.50 Maximum rated output load
 
2.1.1.5 
TABLE: energy hazards measurements 
Measured 
between 
Max. V 
(Uoc) 
Max. A 
(Isc) 
V of Max. 
power 
A of Max. 
power 
Max. power 
Bridged by 
test finger 
Output terminal 
25.6 Vdc 
3.7 A 
23.5 Vdc 
3.7 A 
86.3 VA 
No 
 
2.10.3 and 
2.10.4 
TABLE: clearance and creepage distance measurements 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s.
 (V) 
required cl
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
PCB solder side
 
L to N before fusing resistor (RF1) 
(FI) 
340 240 
1.5 
7.4 
2.5 
9.2 
Primary and secondary (two side 
of CY1) (RI) 
550 240 
4.4 
7.0 
5.0 
7.0 
Primary and secondary (two side 
of U2) (RI) 
550 240 
4.4 
5.7 
5.0 
9.0 
Primary traces (F1) to user 
accessible parts (RI) 
550 240 
4.4 
9.1 
5.0 
9.1 
PCB component side
 
L and N before fusible resistor 
(RF1) (FI) 
340 240 
1.5 
9.2 
2.5 
9.2 
Primary and secondary (two side 
of CY1) (RI) 
550 240 
4.4 
7.3 
5.0 
7.3 
Primary and secondary (two side 
of U2) (RI) 
550 240 
4.4 
6.5 
5.0 
6.5 
Primary components (BD1) to 
secondary components (HS2) (RI) 
550 240 
4.4 
10.2 
5.0 
10.2 
Primary components (HS1) to user 
accessible parts (RI) 
550 240 
4.4 
5.1 
5.0 
5.1 
Secondary components (U3) to 
primary components (HS1) (RI) 
550 240 
4.4 
9.4 
5.0 
9.4 
 
 
 
 
Page 36 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
2.10.3 and 
2.10.4 
TABLE: clearance and creepage distance measurements 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s.
 (V) 
required cl
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
Secondary component L4 to core
3)
 
of transformer (RI) 
550 240 
4.4 
5.5 
5.0 
5.5 
Secondary component C6&C7 to 
core
3)
 of transformer (RI) 
550 240 
4.4 
6.9 
5.0 
6.9 
Secondary component C8&L3 to 
core
3)
 of transformer (RI) 
550 240 
4.4 
8.1 
5.0 
8.1 
Transformer (T1)
 
Secondary to core
3)
 (RI) 
550 240 
4.4 
5.8 
5.0 
5.8 
Primary to secondary (RI) 
550 240 
4.4 
8.8 
5.0 
8.8 
Note: 
1)  FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation. 
2)  A force of 10 N is applied to the internal components and 250 N is applied to the enclosure for 
measuring. 
3)  The core of transformer (T1) is considered as primary component, the triple insulation wire are used as 
secondary winding of transformer. 
4)  The required dcr was consider 250 Vrms. 
Page of 81