Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate ▷ View online
Page 21 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1 General
P
5.1.2
Equipment under test (EUT)
P
5.1.3 Test
circuit
Test circuit as in figure 5A is
used
P
5.1.4 Application
of
measuring instrument
Measuring instrument as in
annex D.1 is used
P
5.1.5 Test
procedure
P
5.1.6 Test
measurements
P
Test
voltage
(V) ................................................ : Input: 264 Vac, 60 Hz
⎯
Measured touch current (mA) ........................... : U2
/
500 = 0.17 mA max.
between L&N and secondary
circuit;
U2 / 500 = 0.01 mA max.
U2 / 500 = 0.01 mA max.
between L&N and enclosure
covered with metal foil
⎯
Max. allowed touch current (mA) ...................... : 0.25
mA
⎯
Measured protective conductor current (mA) ... :
⎯
Max. allowed protective conductor current (mA) :
⎯
5.1.7 Equipment
with
touch current exceeding
3.5 mA ............................................................. :
No such equipment
N/A
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and
from telecommunication networks
No TNV circuit within the EUT
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
No TNV circuit within the EUT
N/A
Test
voltage (V) ................................................ :
⎯
Measured touch current (mA) ........................... :
⎯
Max. allowed touch current (mA) ...................... :
⎯
5.1.8.2
Summation of touch currents from
telecommunication networks ..............................:
No TNV circuit within the EUT
N/A
5.2 Electric
strength
P
5.2.1 General
(see appended table 5.2)
P
5.2.2 Test
procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
(see appended table 5.3)
P
5.3.2 Motors
No such device
N/A
5.3.3
Transformers
(see appended Annex C)
P
5.3.4 Functional
insulation........................................... : Methods a), b) and c)
P
Page 22 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
5.3.5 Electromechanical
components
No such components within
EUT
N/A
5.3.6
Simulation of faults
(see appended table 5.3)
P
5.3.7 Unattended
equipment
There are no thermostats and
similar components within the
EUT
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
P
Page 23 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1 Requirements
N/A
Test
voltage (V) ................................................ :
⎯
Current in the test circuit (mA) ....................... :
⎯
6.1.2.2 Exclusions........................................................... :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1 Separation
requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1 Impulse
test
N/A
6.2.2.2 Steady-state
test
N/A
6.2.2.3 Compliance
criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A)....................................... :
⎯
Current
limiting method ...................................... :
⎯
Page 24 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service
persons, and users of other equipment
connected to the system, from hazardous
voltages in the equipment
persons, and users of other equipment
connected to the system, from hazardous
voltages in the equipment
N/A
7.2
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
7.3
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.3.1 General
N/A
7.3.2
Voltage surge test
N/A
7.3.3 Impulse
test
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man4) service manuals if exist.