EMC - CB Certificate
Brand
Device
Audio
File
go-play-micro-sm4.pdf
Date

Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate ▷ View online

 
 
 
 
Page 17 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
 
4 PHYSICAL 
REQUIREMENTS 
4.1 Stability 
 
Angle of 10
° 
 P 
 Test: 
force (N).......................................................: The EUT mass is 0.3 kg 
N/A 
 
4.2 Mechanical 
strength 
4.2.1 General 
 P 
4.2.2 
Steady force test, 10 N 
The EUT is still complying with 
relevant requirements of this 
standard after 10 N force is 
applied to the components 
4.2.3 
Steady force test, 30 N 
No internal enclosure in the 
sense of this standard 
N/A 
4.2.4 
Steady force test, 250 N 
The EUT is still complying with 
relevant requirements of this 
standard (all the enclosure 
materials listed in the table 
1.5.1 are tested) 
4.2.5 Impact 
test 
The EUT is still complying with 
relevant requirements of this 
standard (all the enclosure 
materials listed in the table 
1.5.1 are tested) 
 Fall 
test 
 
 Swing 
test 
 
4.2.6 Drop 
test 
The EUT is still complying with 
relevant requirements of this 
standard (all the enclosure 
materials listed in the table 
1.5.1 are tested) 
4.2.7 
Stress relief test 
84.8 
°C, all the enclosure 
materials listed in the table 
1.5.1 are tested 
4.2.8 
Cathode ray tubes 
No such device within the EUT 
N/A 
 
Picture tube separately certified ......................... :   N/A 
4.2.9 
High pressure lamps 
No such device within the EUT 
N/A 
4.2.10 
Wall or ceiling mounted equipment; force (N)  .. :  The EUT is not such equipment 
N/A 
 
4.3 
Design and construction   
4.3.1 
Edges and corners 
The outer surface of the EUT is 
smooth 
 
 
 
 
Page 18 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
4.3.2 
Handles and manual controls; force (N)............. :  No such device within the EUT 
N/A 
4.3.3 Adjustable 
controls 
 
No such device within the EUT 
N/A 
4.3.4 
Securing of parts 
The enclosures are fixed by 
ultrasonic welding 
4.3.5 
Connection of plugs and sockets 
No such device within the EUT 
N/A 
4.3.6 
Direct plug-in equipment 
 
N/A 
 
Dimensions (mm) of mains plug for direct 
plug-in    .............................................................. : 
 N/A 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N).............................. : 
 N/A 
4.3.7 
Heating elements in earthed equipment 
No such device within the EUT 
N/A 
4.3.8 Batteries 
No such device within the EUT 
N/A 
4.3.9 
Oil and grease 
No such materials within the 
EUT 
N/A 
4.3.10 
Dust, powders, liquids and gases 
The EUT does not produce 
such things 
N/A 
4.3.11 
Containers for liquids or gases 
No such device within the EUT 
N/A 
4.3.12 Flammable liquids............................................... :  No such materials within the 
EUT 
N/A 
 Quantity 
of 
liquid (l)............................................. :   N/A 
 
Flash point (
°C)................................................... :   N/A 
4.3.13 Radiation; 
type of radiation ............................... :  The EUT does not produce 
ionising radiation   
N/A 
4.3.13.1 General 
 N/A 
4.3.13.2 Ionizing 
radiation 
 
 N/A 
 Measured 
radiation (pA/kg) ................................:  
⎯ 
 Measured 
high-voltage (kV) ................................:  
⎯ 
 Measured 
focus 
voltage (kV) ...............................:  
⎯ 
 CRT 
markings ......................................................:  
⎯ 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation  .. :   
N/A 
 
Part, property, retention after test, flammability 
classification ..................................................... : 
 
N/A 
4.3.13.5 
Laser (including LEDs) 
 
 Laser 
class ........................................................ :  Less than 1 mW 
⎯ 
4.3.13.6 Other 
types ....................................................... :   
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
 
 
 
 
Page 19 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
4.4.1 General 
No hazardous moving parts 
within the EUT 
N/A 
4.4.2 
Protection in operator access areas 
 N/A 
4.4.3 
Protection in restricted access locations   
 N/A 
4.4.4 
Protection in service access areas 
 N/A 
4.5 Thermal 
requirements 
4.5.1 Maximum 
temperatures 
(see appended table 4.5) 
 
Normal load condition per Annex L .................... :  Operated in the most 
unfavourable way of operation 
given in the operating 
instructions until steady 
conditions established 
4.5.2 
Resistance to abnormal heat 
(see appended table 4.5.2) 
 
4.6 
Openings in enclosures 
N/A 
4.6.1 
Top and side openings 
 
N/A 
 Dimensions (mm)  .............................................. :  No openign at all
 
⎯ 
4.6.2 
Bottoms of fire enclosures 
 
N/A 
 Construction 
of the bottom ................................. :  No openings at all 
⎯ 
4.6.3 
Doors or covers in fire enclosures 
No such device within the EUT 
N/A 
4.6.4 
Openings in transportable equipment 
No openings at all 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barriers or screen provided 
to complying with the relevant 
requirements of sub-clause 
4.6.1, 4.6.2 or 4.6.4 
N/A 
 
Conditioning temperature (
°C)/time (weeks)...... :   
⎯ 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame   
 
Method 1, selection and application of 
components wiring and materials 
(see appended table 4.7) 
 
Method 2, application of all of simulated fault 
condition tests 
 N/A 
4.7.2 
Conditions for a fire enclosure 
Fire enclosure is provided 
4.7.2.1 
Parts requiring a fire enclosure 
 
4.7.2.2 
Parts not requiring a fire enclosure 
 
N/A 
4.7.3 Materials 
 
4.7.3.1 General 
 P 
4.7.3.2 
Materials for fire enclosures 
(see appended table 1.5.1) 
 
 
 
 
Page 20 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
 N/A 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
(see appended table 1.5.1) 
4.7.3.5 
Materials for air filter assemblies 
No such device within the EUT 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No such device within the EUT 
N/A 
 
Page of 81