Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate ▷ View online
Page 2 of 70
Report No.: JGZ0512196-3
TRF No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
Test item description
...................: I. T. E. Power supply
Trademark ......................................: LEI / TECTROL (logo)
Model and/or type reference ...........: NU60-9240***-I3
Serial number .................................: ⎯
Rating(s) ...........................................: Input: 100-240 Vac, 50/60 Hz, 2 A, Class II
Model and/or type reference ...........: NU60-9240***-I3
Serial number .................................: ⎯
Rating(s) ...........................................: Input: 100-240 Vac, 50/60 Hz, 2 A, Class II
Output: 24 Vdc, 0.5 - 2.5 A
Particulars: test item vs. test requirements
Equipment mobility .................................... : Movable (transportable)
Operating condition ..................................... : Continuous
Mains supply tolerance (%) ......................... : + 6 %, + 10 % and - 10 % (+ 10 % required by applicant)
Tested for IT power systems ..................... : Yes
IT testing, phase-phase voltage (V) :
Equipment mobility .................................... : Movable (transportable)
Operating condition ..................................... : Continuous
Mains supply tolerance (%) ......................... : + 6 %, + 10 % and - 10 % (+ 10 % required by applicant)
Tested for IT power systems ..................... : Yes
IT testing, phase-phase voltage (V) :
230 V for Norway
Class of equipment .................................... : Class II
Mass of equipment (kg)............................... : 0.3 kg
Protection against ingress of water ........... : IP20
Mass of equipment (kg)............................... : 0.3 kg
Protection against ingress of water ........... : IP20
Test case verdicts
Test case does not apply to the test object : N/A
Test item does meet the requirement ........ : P(ass)
Test item does not meet the requirement .. : F(ail)
Testing
Date of receipt of test item ......................... : December 14, 2005
Date(s) of performance of test ................... : December 14, 2005 – January 26, 2006
Date(s) of performance of test ................... : December 14, 2005 – January 26, 2006
Page 3 of 70
Report No.: JGZ0512196-3
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
General remarks
”This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a
NCB, in accordance with IECEE 02”.
NCB, in accordance with IECEE 02”.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
”(see remark #)” refers to a remark appended to the report.
“(see Annex #)” refers to an annex appended to the report.
Throughout this report a point is used as the decimal separator.
When determining of test conclusion, the Measurement Uncertainty of test has been considered.
Group differences, special national deviations of all CENELEC countries.
The appliances comply with the requirement of this standard.
General product information:
Model NU60-9240***-I3
1. The ”***” denote the output current, which can be ”050” (0.5 A) to ”250” (2.5 A).
2. In series NU60-9240***-I3, there exactly only one product, but marked with different rated output current
for trading purpose. Tests are conducted on model NU60-9240250-I3, which can be representative for
other models.
other models.
3. The output terminal was shown in appendix III, which was alternative with other type.
Page 4 of 70
Report No.: JGZ0512196-3
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
Copy of marking plate and summary of test results
(information/comments):
(Representative)
Note:
The above markings are the minimum requirements required by the safety standard. For the final
production samples, the additional markings which do not give rise to misunderstanding may be added.