Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online
- Page 9 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
Photographs: Continued
Top of PCB View (5)
- Page 10 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
Bottom of PCB View (6)
- Page 11 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1 GENERAL
P
1.5 Components
P
1.5.1 General
P
Comply with IEC 60950-1 or relevant component
standard
standard
Refer to appended table 1.5.1.
P
1.5.2
Evaluation and testing of components
Certified components are used
in accordance with their ratings,
certifications and they comply
with applicable parts of this
standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
in accordance with their ratings,
certifications and they comply
with applicable parts of this
standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
Class III equipment to be
supplied by a separately
approved power supply with an
SELV output. Power supply not
evaluated. Refer to Summary of
testing.
supplied by a separately
approved power supply with an
SELV output. Power supply not
evaluated. Refer to Summary of
testing.
N/A
1.5.5 Interconnecting
cables
N/A
1.5.6
Capacitors in primary circuits .............................: Class III equipment. No such
capacitors.
N/A
1.5.7
Double insulation or reinforced insulation bridged
by components
by components
No such components bridging
double or reinforced insulation.
double or reinforced insulation.
N/A
1.5.7.1
General
Class III equipment.
N/A
1.5.7.2 Bridging
capacitors
N/A
1.5.7.3 Bridging
resistors
N/A
1.5.7.4
Accessible parts
SELV circuits only, Class III
equipment.
equipment.
N/A
- Page 12 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.6 Power
interface
P
1.6.1
AC power distribution systems
Class III equipment.
N/A
1.6.2
Input current
Refer to appended table 1.6.2.
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7 Markings
and
instructions
P
1.7.1
Power rating
Marking not required, however
the marking is located on the
outside surface of the
equipment.
the marking is located on the
outside surface of the
equipment.
P
Rated voltage(s) or voltage range(s) (V) ........... : 18Vdc
P
Symbol for nature of supply, for d.c. only ........... : IEC 60417-1, symbol No. 5031,
is used.
P
Rated frequency or rated frequency range (Hz) : DC rated.
N/A
Rated current (mA or A) ..................................... : 3.3A
P
Manufacturer’s name or trademark or
identification mark .............................................. :
identification mark .............................................. :
P
Type/model or type reference ............................. : Go+Play
P
Symbol for Class II equipment only ................... : The equipment is Class III.
N/A
Other symbols .................................................... : The additional marking does
not give rise to
misunderstandings.
misunderstandings.
P
Certification marks ............................................. : Refer to copy of markings.
P
1.7.2
Safety instructions
Provided with marking
regarding use of specified
power supply (Not required),
refer to Copy of marking plate.
regarding use of specified
power supply (Not required),
refer to Copy of marking plate.
N/A
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................. : No voltage selector.
N/A
1.7.5
Power outlets on the equipment ........................ : No standard power outlet.
N/A
1.7.6 Fuse
identification
.............................................. :
No
fuses.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.