- Page 36 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV circuits. 
N/A 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
No TNV circuits. 
N/A 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV circuits. 
N/A 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
2.7.1 
C: Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-
circuits and earth faults in 
PRIMARY CIRCUITS
protective devices shall be included either as 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), 
b) and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as parts of 
the equipment; 
b) for components in series with the mains input 
to the equipment such as the supply cord, 
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided 
by protective devices in the building installation; 
c) it is permitted for 
PLUGGABLE EQUIPMENT TYPE
 B 
or 
PERMANENTLY CONNECTED EQUIPMENT
, to rely 
on dedicated overcurrent and short-circuit 
protection in the building installation, provided 
that the means of protection, e.g. fuses or circuit 
breakers, is fully specified in the installation 
instructions. 
If reliance is placed on protection in the building 
installation, the installation instructions shall so 
state, except that for 
PLUGGABLE EQUIPMENT TYPE 
A the building installation shall be regarded as 
providing protection in accordance with the rating 
of the wall socket outlet. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
 
S (GB): To protect against excessive currents 
and short-circuits in the 
PRIMARY CIRCUIT 
of
 
DIRECT PLUG
-
IN EQUIPMENT
, protective devices 
shall be included as integral parts of the 
DIRECT 
PLUG
-
IN EQUIPMENT
Not direct plug-in equipment. 
N/A 
2.7.2 C: 
Void. 
Considered. 
N/A 
 
 
- Page 37 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.10.2 
C: Replace in the first line "(see also 1.4.7)" by 
"(see also 1.4.8)". 
Considered. 
2.10.3.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
.
  MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage and will remain at 230 V in 
case of a single earth fault. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.1.1 
S (CH): Supply cords of equipment having a 
RATED CURRENT
 not exceeding 10 A shall be 
provided with a plug complying with SEV 1011 or 
IEC 60884-1 and one of the following dimension 
sheets: 
SEV 6532-2.1991, Plug Type 15, 3P+N+PE  250/400 V, 10 A
SEV 6533-2.1991, Plug Type 11, L+N 
250 V, 10 A 
SEV 6534-2.1991, Plug Type 12, L+N+PE  250 V, 10 A 
In general, EN 60309 applies for plugs for 
currents exceeding 10A. However, a 16 A plug 
and socket-outlet system is being introduced in 
Switzerland, the plugs of which are according to 
the following dimension sheets, published in 
February 1998: 
SEV 5932-2.1998, Plug Type 25, 3L+N+PE   230/400 V, 16 A
SEV 5933-2.1998, Plug Type 21, L+N 
250 V, 16 A 
SEV 5934-2.1998, Plug Type 23, L+N+PE  250 V, 16 A
 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.1.1 
S (DK): Supply cords of single-phase equipment 
having a rated current not exceeding 13 A shall 
be provided with a plug according to the Heavy 
Current Regulations, Section 107-2-D1. 
C
LASS 
I
 EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against 
indirect contact is required according to the 
wiring rules shall be provided with a plug in 
accordance with standard sheet DK 2-1a or 
DK 2-5a. 
If poly-phase equipment and single-phase 
equipment having a 
RATED CURRENT
 exceeding 
13 A is provided with a supply cord with a plug, 
this plug shall be in accordance with the Heavy 
Current Regulations, Section 107-2-D1 or 
EN 60309-2. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
 
 
- Page 38 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
3.2.1.1 
S (ES): Supply cords of single-phase equipment 
having a rated current not exceeding 10 A shall 
be provided with a plug according to 
UNE 20315:1994. 
Supply cords of single-phase equipment having a 
rated current not exceeding 2,5 A shall be 
provided with a plug according to 
UNE-EN 50075:1993. 
C
LASS 
I
 EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against 
indirect contact is required according to the 
wiring rules, shall be provided with a plug in 
accordance with standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply 
cord with a plug, this plug shall be in accordance 
with UNE-EN 60309-2. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.1.1 
S (GB): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to BS 1363 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 'standard plug' in accordance with 
Statutory Instrument 1768:1994 – The Plugs and 
Socket etc. (Safety) Regulations 1994, unless 
exempted by those regulations. 
NOTE – 'Standard plug' is defined in SI 1768:1994 and 
essentially means an approved plug conforming to BS 1363 
or an approved conversion plug. 
 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.1.1 
S (IE): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to I.S. 411 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 13 A plug in accordance with 
Statutory Instrument 525:1997 – National 
Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic 
Use) Regulations 1997. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.3 
C: Delete Note 1 and in Table 3A, delete the 
conduit sizes in parentheses. 
Considered. 
 
 
- Page 39 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
3.2.5.1 C: 
Replace 
"60245 IEC 53"  by "H05 RR-F"; 
"60227 IEC 52"  by "H03 VV-F or H03 VVH2-F"; 
"60227 IEC 53"  by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the 
following: 
Up to and including 6  
 
0,75
1)
 
Over 6 up to and including 10  (0,75)
2) 
1,0 
Over 10 up to and including 16 (1,0)
3)
 1,5 
In the Conditions applicable to Table 3B delete 
the words "in some countries" in condition 
1)
In Note 1, applicable to Table 3B, delete the 
second sentence. 
Considered. 
N/A 
3.2.5.1 
S (GB): A power supply cord with conductor of 
1,25 mm
2
 is allowed for equipment with a rated 
current over 10 A and up to and including 13 A. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.3.4 
C: In Table 3D, delete the fourth line: conductor 
sizes for 10 to 13A, and replace with the 
following: 
Over 10 up to and including 16  1,5 to 2,5 1,5 to 

Delete the fifth line: conductor sizes for 13 to 
16 A. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.3.4 
S (GB): The range of conductor sizes of flexible 
cords to be accepted by terminals for equipment 
with a
 RATED CURRENT
 of over 10 A up to and 
including 13 A is: 
- 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional 
area. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
4.3.6 
S (GB): The torque test is performed using a 
socket outlet complying with BS 1363 and the 
plug part of 
DIRECT PLUG
-
IN EQUIPMENT
 shall be 
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 
12.9, 12.11, 12.12, 12.16 and 12.17, except that 
the test of 12.17 is performed at not less than 
125
°C. 
Not direct plug-in equipment. 
N/A 
 
S (IE): D
IRECT PLUG
-
IN EQUIPMENT
 is known as 
plug similar devices. Such devices shall comply 
with Statutory Instrument 526:1997 – National 
Standards Authority of Ireland (Section 28) 
(Electrical plugs, plug similar devices and 
sockets for domestic use) Regulations, 1997. 
Not direct plug-in equipment. 
N/A 