EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm4.pdf
Date

Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online

 
 
- Page 48 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
 
2.1.1.5 c2)  TABLE: stored energy 
N/A 
 
Capacitance C (µF) 
Voltage U (V) 
Energy E (J) 
 
 
 
 
 
 
supplementary information:  
 
 
2.2 
TABLE: evaluation of voltage limiting components in SELV circuits 
N/A 
 
Component (measured between) 
max. voltage (V) 
(normal operation) 
Voltage Limiting Components 
 
V peak 
V d.c. 
 
 
 
 
 
 
 
 
 
 
Fault test performed on voltage limiting components 
Voltage measured (V) in SELV circuits 
(V peak or V d.c.) 
 
 
 
 
supplementary information: 
 
 
2.5 TABLE: 
limited 
power 
sources 
N/A 
 
Circuit output tested: ……. 
Measured Uoc (V) with all load circuits 
disconnected: ……. 
 
I
sc 
(A) 
VA 
 
Meas. 
Limit 
Meas. 
Limit 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
Output from the power supply complied with limited power source, no testing required, see PSU test report.
 
 
 
 
 
 
 
 
 
 
- Page 49 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
2.10.2 
Table: working voltage measurement 
N/A 
 
Location 
RMS voltage (V)
Peak voltage (V) Comments  
 
 
 
 
 
 
 
 
supplementary information: 
 
 
2.10.3 –  
2.10.4 
TABLE: clearance and creepage distance measurements 
N/A 
 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
 (V) 
required cl
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
2.10.5 
TABLE: distance through insulation measurements 
N/A 
 
distance through insulation di at/of: 
Up 
(V) 
test voltage 
 (V) 
required di 
 (mm) 
di 
(mm) 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
- Page 50 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
 
4.3.8 TABLE: 
Batteries 
 
Battery category .......................................... :  Alkaline or Carbon-Zinc 
Manufacturer ............................................... : Various 
Type / model................................................ :  D-Cell /Various 
Voltage ........................................................ :  1.5V x 8 pcs = 12Vdc 
Capacity....................................................... : Various 
Tested and Certified by (incl. Ref. No.) ....... :  None. 
 
Circuit protection diagram: 
 
 
Q4
2SC2712
Q3
2SC2712
D4
sb540
18V
U1B
TS393
U1A
TS393
+ V1
12V
Q5
IRF7416
Q2
IRF7416
Q1
IRF7416
R6
1meg
R5
3meg
R4
1meg
R3
3meg
R1
100k
 
 
 
 
 
 
 
 
 
 
- Page 51 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15) 
Location of replaceable battery 
 
 
 
Close to the battery 
 
In the servicing instructions  
In the operating instructions 
 
 
4.3.8 TABLE: 
Batteries 
 
The tests of 4.3.8 are applicable only when 
appropriate battery data is not available 
 
Is it possible to install the battery in a reverse 
polarity position? 
Yes, no hazard, see protection diagram: 
Temperature 25°C 
 
 
Non-rechargeable batteries 
Rechargeable batteries 
 
Discharging 
Unintentional 
charging 
Charging 
Discharging 
Reversed 
charging 
 
Meas. 
current 
Manuf. 
spec. 
 
Meas. 
current 
Manuf. 
spec. 
Meas. 
current 
Manuf. 
spec. 
Meas. 
current 
Manuf. 
spec. 
Max 
current 
during 
normal 
conditions 
0.25  
N/A 
Not possible, see 
circuit protection 
diagram. 
 
 
 
 
 
 
Max 
current 
with 
undistorte
d sound 
output. 
3.2A N/A  Not 
possible, 
see 
circuit protection 
diagram. 
 
 
 
 
 
 
Max 
current 
during fault 
conditions 
(Battery  
S-c) 
13.2A N/A  Not 
possible, 
see 
circuit protection 
diagram. 
 
 
 
 
 
 
supplementary information: 
 
 