Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online

IEC 60950-1 (ed.1) 
 - 
Page 
2
 of 
8
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
3.2.5.1 
Modify Table 3B as follows: 
Delete the first four rows and replace with 
Delete Note 1 
Considered. 
N/A
 
4.3.6 
Replace paragraph three with: 
Equipment with a plug portion, suitable for 
insertion into a 10 A 3-pin flat-pin socket-outlet 
complying with AS/NZS 3112, shall comply with 
the requirements in AS/NZS 3112 for equipment 
with integral pins for insertion into socket-outlets. 
Not direct plug-in equipment. 
N/A 
4.3.13.5  Add the following to the end of first paragraph: 
‘or AS/NZS 2211.1’. 
No laser components. LED is 
diffused type. 
N/A 
4.7 
Add the following paragraph: 
For alternative tests refer to Clause 4.7.201. 
Class III equipment. 
N/A 
IEC 60950-1 (ed.1) 
 - 
Page 
3
 of 
8
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
4.7.201 
Add the following after Clause 4.7.3.6: 
4.7.201 Resistance to fire – Alternative tests 
4.7.201.1 General 
Parts of non-metallic material shall be resistant to 
ignition and spread of fire. 
This requirement does not apply to decorative 
trims, knobs and other parts unlikely to be ignited 
or to propagate flames originating from inside the 
apparatus, or the following: 
a) Components that are contained in an enclosure 
having a flammability category of FV-0 according 
to AS/NZS 4695.707 and having openings only for 
the connecting wires filling the openings 
completely, and for ventilation not exceeding 1 
mm in width regardless of length. 
b) The following parts which would contribute 
negligible fuel to a fire: 
- small mechanical parts, the mass of which does 
not exceed 4 g, such as mounting parts, gears, 
cams, belts and bearings; 
- small electrical components, such as capacitors 
with a volume not exceeding 1750mm
3
, integrated 
circuits, transistors and optocoupler packages, if 
these components are mounted on material of 
flammability category FV-1, or better, according to 
AS/NZS 4695.707. 
NOTE: In considering how to minimize propagation of 
fire and what ‘small parts’ are, account should be taken 
of the cumulative effect of small parts adjacent to each 
other for the possible effect of propagating fire from one 
part to another. 
Compliance shall be checked by the tests of 
4.7.201.2, 4.7.201.3, 4.7.201.4 and 4.7.201.5. 
For the base material of printed boards, 
compliance shall be checked by the test of 
4.7.201.5. 
The tests shall be carried out on parts of non-
metallic material which have been removed from 
the apparatus. When the glow-wire test is carried 
out, the parts shall be placed in the same 
orientation as they would be in normal use. 
These tests are not carried out on internal wiring. 
4.7.201.2 Testing of non-metallic materials 
Parts of non-metallic material shall be subject to 
the glow-wire test of AS/NZS 60695.2.11 which 
shall be carried out at 550°C.
 
Not used. 
N/A
 
IEC 60950-1 (ed.1) 
 - 
Page 
4
 of 
8
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
4.7.201 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part. 
4.7.201.3 Testing of insulating materials 
Parts of insulating material supporting 
POTENTIAL IGNITION SOURCES shall be 
subject to the glow-wire test of AS/NZS 
60695.2.11 which shall be carried out at 750°C 
The test shall also be carried out on other parts of 
insulating material which are within a distance of 3 
mm of the connection. 
NOTE: Contacts in components such as switch 
contacts are considered to be connections. 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle-flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test shall not be tested. 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
Not used. 
N/A
 
IEC 60950-1 (ed.1) 
 - 
Page 
5
 of 
8
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
4.7.201 
The needle-flame test shall not be carried out on 
parts of material classified as V-0 or V-1 
according to IEC 60695-11-10, provided that the 
sample tested was not thicker than the relevant 
part. 
4.7.201.4 Testing in the event of non-
extinguishing material 
If the parts, other than enclosures, do not 
withstand the glow-wire tests of 4.7.201.3, by 
failure to extinguish within 30 s after the removal 
of the glow-wire tip, the needle-flame test detailed 
in 4.7.201.3 shall be made on all parts of non-
metallic material which are within a distance of 50 
mm or which are likely to be impinged upon by 
flame during tests of 4.7.201.3. Parts shielded by 
a separate barrier which meets the needle-flame 
test need not be tested. 
NOTE 1: If the enclosure does not withstand the glow- 
wire test the equipment is considered to have failed to 
meet the requirements of Clause 4.7.201 without the 
need for consequential testing. 
NOTE 2: If other parts do not withstand the glow-wire 
test due to ignition of the tissue paper and if this 
indicates that burning or glowing particles can fall onto 
an external surface underneath the equipment, the 
equipment is considered to have failed to meet the 
requirements of Clause 4.7.201 without the need for 
consequential testing. 
NOTE 3: Parts likely to be impinged upon by the flame 
are considered to be those within the envelope of a 
vertical cylinder having a radius of 10 mm and a height 
equal to the height of the flame, positioned above the 
point of the material supporting, in contact with, or in 
close proximity to, connections.
 
Not used. 
N/A
 