DOWNLOAD Harman Kardon GO AND PLAY (serv.man4) Service Manual ↓ Size: 2.46 MB | Pages: 127 in PDF or view online for FREE

Model
GO AND PLAY (serv.man4)
Pages
127
Size
2.46 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm4.pdf
Date

Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online

IEC 60950-1 (ed.1) 
 - 
Page 
2
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
1.7.1 
Equipment for use on a.c. mains supply systems 
with a neutral and more than one phase 
conductor (e.g. 120/240 V, 3-wire) require a 
special marking format for electrical ratings. 
A voltage rating that exceeds an attachment plug 
cap rating is only permitted if it does not exceed 
the extreme operating conditions in Table 2 of 
CAN/CSA C22.2 No. 235, and if it is part of a 
range that extends into the Table 2 “Normal 
Operating Conditions”. Likewise, a voltage rating 
shall not be lower than the specified “Normal 
Operating Conditions”, unless it is part of a range 
that extends into the “Normal Operating 
Conditions”. 
Class III equipment. 
N/A
 
2.5 
Where a fuse is used to provide Class 2, Limited 
Power Source, or TNV current limiting, it shall not 
be operator-accessible unless it is not 
interchangeable. 
No such fuse provided. 
N/A
 
2.7.1 
Suitable NEC/CEC branch circuit protection rated 
at the maximum circuit rating is required for all 
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch 
circuit protection is not suitable. 
Power distribution transformers distributing power 
at 100 V or more, and rated 10 kVA or more, 
require transformer overcurrent protection. 
No standard supply outlets, 
receptacles, lampholders or such 
transformers. 
N/A
 
3.2 
Wiring methods (terminals, leads etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC. 
Class III equipment. 
N/A
 
3.2.1 
Power supply cords are required to have 
attachment plugs rated not less than 125% of the 
rated current of the equipment. 
Class III equipment. 
N/A 
3.2.3 
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs. 
Class III equipment. The 
equipment is not permanently 
connected to the mains. 
N/A
 
3.2.5 
Power supply cords are required to be no longer 
than 4.5m in length. 
Flexible power supply cords are required to be 
compatible with Article 400 of the NEC, and 
Tables 11 and 12 of the CEC. 
Class III equipment 
N/A
 
3.2.9 
Permanently connected equipment is required to 
have a suitable wiring compartment and wire 
bending space.
 
Class III equipment. The 
equipment is not permanently 
connected to the mains. 
N/A
 
3.3 
Wiring terminals and associated spacings for field 
wiring connections shall comply with CSA C22.2 
No. 0. 
Class III equipment 
N/A
 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm
2
). 
Class III equipment 
 
IEC 60950-1 (ed.1) 
 - 
Page 
3
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
3.3.4 
Terminals for permanent wiring, including 
protective earthing terminals, are required to be 
suitable for U.S./Canadian wire gauge sizes, 
rated 125% of the equipment rating, and 
specially marked when specified (1.7.7).  
Class III equipment. The 
equipment is not permanently 
connected to the mains. 
N/A
 
3.4.2 
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12 A, or if the 
motor has a nominal voltage rating greater than 
120 V, or is rated more than 1/3 hp (locked rotor 
current over 43 A). 
No such motors in the 
equipment. 
N/A
 
3.4.8 
Vertically-mounted disconnect switches and 
circuit breakers are required to have the “on” 
position indicated by the handle in the up 
position. 
No switch as disconnect device. 
N/A
 
3.4.11 
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit. 
No such battery in the 
equipment. 
N/A
 
4.3.12 
The maximum quantity of flammable liquid stored 
in equipment is required to comply with NFPA 30.
No flammable liquids within the 
equipment. 
N/A
 
4.3.13 
Equipment with lasers is required to meet the 
Code of Federal Regulations 21 CFR 1040 (and 
the Canadian Radiation Emitting Devices Act, 
REDR C1370). 
No lasers. LEDs are diffused 
type. 
P
 
4.7 
For computer room applications, automated 
information storage systems with combustible 
media greater than 27 cubic feet are required to 
have a provision for connection of either 
automatic sprinklers or a gaseous agent 
extinguishing system with an extended 
discharge. 
The equipment has no 
combustible area greater than 27 
cubic feet. 
N/A
 
4.7.3.1 
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 
m
2
 or a single dimension greater than 1.8 m are 
required to have a flame spread rating of 50 or 
less. For other applications, enclosures with the 
same dimensions require a flame spread rating 
of 200 or less. 
The equipment has no 
combustible material greater 
than 0.93m
2
 or single dimension 
greater than 1.8m. 
N/A
 
Annex H  Equipment that produces ionizing radiation is 
required to comply with the Code of Federal 
Regulations, 21 CFR 1020 (and Canadian 
Radiation Emitting Devices Act, REDR C1370). 
The equipment does not produce 
ionizing radiation. 
N/A
 
IEC 60950-1 (ed.1) 
 - 
Page 
4
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
 
The following key national differences are based on requirements other than national regulatory 
requirements. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL 60950-1, First Edition) 
should be consulted for further details on the national differences summarized below
 
1.5.1 
Components of equipment must be suitable for 
the application, and must comply with the 
requirements of the equipment standard and the 
applicable national (Canadian and/or U.S.) 
component or material standards, as far as they 
may apply. 
The acceptance will be based on the following: 
I) A component Certified by a Canadian or U.S. 
National Certification Body (NCB) to a Canadian 
or U.S. component standard will be checked for 
correct application and use in accordance with its 
specified rating. Where necessary, it will also be 
subject to the applicable tests of the equipment 
standard. 
J) A component, which has a CB Test Certificate 
for compliance with a relevant IEC component 
standard, will be checked for correct application 
and use in accordance with its specified ratings. 
Where necessary, it will also be subject to the 
applicable tests of the equipment standard, and 
to the applicable tests of the Canadian and/or 
U.S. component or material standard, under the 
conditions occurring in the equipment. 
K) A component, which has no approval as in A) 
or B) above or which is used not in accordance 
with its specified ratings, will be subject to the 
applicable tests of the equipment standard, and 
to the applicable tests of the Canadian and/or 
U.S. component or material standard, under the 
conditions occurring in the equipment. 
L) Some components may require annual re-
testing, which may be carried out by the 
manufacturer, CSA International or another 
laboratory
 
All critical components are IEC, 
CSA, or UL certified. Refer to list 
of critical components in main 
CB report (appended table 
1.5.1). 
P
 
2.3.1 
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 42.4 
Vp or 60 Vdc, the maximum acceptable current 
through a 2000 ohm resistor (or greater) 
connected across the voltage source with other 
loads disconnected is 7.1 mA peak or 30 mA dc 
under normal operating conditions. 
TNV not provided. 
N/A
 
2.3.2 
In the event of a single fault, the limits of 2.2.3 
apply to SELV Circuits and accessible conductive 
parts. 
No TNV circuitry. 
N/A
 
2.6.3.4 
When subject to impedance testing, protective 
earthing and bonding are required to be 
subjected to the additional test conditions 
specified. 
Class III equipment. 
N/A
 
IEC 60950-1 (ed.1) 
 - 
Page 
5
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
3.2.1.2 
Equipment connected to centralized d.c. power 
system, and having one pole of the DC mains 
input terminal connected to the main protective 
earthing terminal in the equipment, is required to 
comply with special earthing, wiring, marking and 
installation instruction requirements. 
Class III equipment. Not for 
connection to DC mains. 
N/A
 
4.2.8.1 
Enclosures around CRT’s with a face diameter of 
160 mm or more are required to reduce the risk 
of injury due to the implosion of the CRT. 
No CRTs in the equipment. 
N/A
 
4.3.2 
Equipment with handles is required to comply 
with special loading tests. 
Tested with additional 5.4kg 
weights fixed to the equipment. 
P
 
5.1.8.3 
Equipment intended to receive 
telecommunication ringing signals is required to 
comply with a special touch current 
measurement tests. 
TNV not provided. 
N/A
 
6.2.1 
Enamel coating on winding wire not considered 
electrical separation unless subjected to special 
investigation. 
TNV not provided. 
N/A
 
6.4 
Equipment intended for connection to 
telecommunication network outside plant cable is 
required to be protected against overvoltage from 
power line crosses in accordance with 6.4 and 
Annex NAC. 
TNV not provided. 
N/A
 
6.5 
Equipment connected to a telecommunications 
network and supplied with an earphone intended 
to be held against, or in the ear is required to 
comply with special acoustic pressure tests. 
TNV not provided. 
N/A
 
M.2 
Continuous ringing signals up to 16 mA only are 
permitted if the equipment is subjected to special 
installation and performance restrictions. 
TNV not provided. 
N/A
 
 
Page of 127
Display

Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.