Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online
IEC 60950-1 (ed.1)
-
Page
2
of
5
-
www.nemko.com
Report No. 70512
2.5
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
No such fuses.
N/A
2.7.1
Suitable NEC/CEC branch circuit protection rated
at the maximum circuit rating is required for all
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch
circuit protection is not suitable.
Power distribution transformers distributing power
at 100 V or more, and rated 10 kVA or more,
require transformer overcurrent protection.
at the maximum circuit rating is required for all
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch
circuit protection is not suitable.
Power distribution transformers distributing power
at 100 V or more, and rated 10 kVA or more,
require transformer overcurrent protection.
No standard supply outlets,
receptacles, lamp holders or
such transformers.
receptacles, lamp holders or
such transformers.
N/A
3.2
Wiring methods (terminals, leads etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
Class III equipment.
N/A
3.2.1
Power supply cords are required to have
attachment plugs rated not less than 125% of the
rated current of the equipment.
attachment plugs rated not less than 125% of the
rated current of the equipment.
Class III equipment.
—
3.2.3
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
Class III equipment. Not
permanently connected to the
mains.
permanently connected to the
mains.
N/A
3.2.5
Power supply cords are required to be no longer
than 4.5m in length.
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
than 4.5m in length.
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
Class III equipment.
N/A
3.2.9
Permanently connected equipment is required to
have a suitable wiring compartment and wire
bending space.
have a suitable wiring compartment and wire
bending space.
Class III equipment. Not
permanently connected to the
mains.
permanently connected to the
mains.
N/A
3.3
Wiring terminals and associated spacings for field
wiring connections shall comply with CSA C22.2
No. 0.
wiring connections shall comply with CSA C22.2
No. 0.
Class III equipment.
N/A
3.3.3
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm
conductors larger than 10 AWG (5.3 mm
2
).
Class III equipment.
N/A
3.3.4
Terminals for permanent wiring, including
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes,
rated 125% of the equipment rating, and
specially marked when specified (1.7.7).
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes,
rated 125% of the equipment rating, and
specially marked when specified (1.7.7).
Class III equipment. Not
permanently connected to the
mains.
permanently connected to the
mains.
.
N/A
3.4.2
Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12 A, or if the
motor has a nominal voltage rating greater than
120 V, or is rated more than 1/3 hp (locked rotor
current over 43 A).
connected equipment with a motor if the
equipment is rated more than 12 A, or if the
motor has a nominal voltage rating greater than
120 V, or is rated more than 1/3 hp (locked rotor
current over 43 A).
No such motors in the
equipment
equipment
.
N/A
3.4.8
Vertically-mounted disconnect switches and
circuit breakers are required to have the “on”
position indicated by the handle in the up
position.
circuit breakers are required to have the “on”
position indicated by the handle in the up
position.
No switch as disconnect device.
N/A
IEC 60950-1 (ed.1)
-
Page
3
of
5
-
www.nemko.com
Report No. 70512
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
No such battery in the
equipment.
equipment.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment is required to comply with NFPA 30.
in equipment is required to comply with NFPA 30.
No flammable liquids within the
equipment.
equipment.
N/A
4.3.13
Equipment with lasers is required to meet the
Code of Federal Regulations 21 CFR 1040 (and
the Canadian Radiation Emitting Devices Act,
REDR C1370).
Code of Federal Regulations 21 CFR 1040 (and
the Canadian Radiation Emitting Devices Act,
REDR C1370).
No lasers. LED’s are diffused
type.
type.
N/A
4.7
For computer room applications, automated
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended
discharge.
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended
discharge.
The equipment has no
combustible area greater than
27 cubic feet.
combustible area greater than
27 cubic feet.
N/A
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m
combustible material measuring greater than 0.9
m
2
or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating
of 200 or less.
less. For other applications, enclosures with the
same dimensions require a flame spread rating
of 200 or less.
The equipment has no
combustible material greater
than 0.93m
combustible material greater
than 0.93m
2
or single dimension
greater than 1.8m.
N/A
Annex H Equipment that produces ionizing radiation is
required to comply with the Code of Federal
Regulations, 21 CFR 1020 (and Canadian
Radiation Emitting Devices Act, REDR C1370).
Regulations, 21 CFR 1020 (and Canadian
Radiation Emitting Devices Act, REDR C1370).
The equipment does not produce
ionizing radiation.
ionizing radiation.
N/A
OTHER DIFFERENCES
The following key national differences are based on requirements other than national regulatory
requirements.
requirements.
IEC 60950-1 (ed.1)
-
Page
4
of
5
-
www.nemko.com
Report No. 70512
1.5.1
Some components and materials associated with
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements.
These components include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, surge suppressors, switches
(including interlock switches), thermal cutoffs,
thermostats, multi-layer transformer winding wire,
tubing, wire connectors, and wire and cables
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements.
These components include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, surge suppressors, switches
(including interlock switches), thermal cutoffs,
thermostats, multi-layer transformer winding wire,
tubing, wire connectors, and wire and cables
All critical components are IEC,
CSA, or UL certified. Refer to list
of critical components in main
CB report refer to appended
table 1.5.1.
CSA, or UL certified. Refer to list
of critical components in main
CB report refer to appended
table 1.5.1.
P
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 Vdc, the maximum acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
ringing signals and with voltages exceeding 42.4
Vp or 60 Vdc, the maximum acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
TNV not provided.
N/A
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
TNV not provided.
N/A
2.6.3.4
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class III equipment.
N/A
3.2.1.2
Equipment connected to centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
Class III equipment. Not for
connection to DC mains.
connection to DC mains.
N/A
4.2.8.1
Enclosures around CRT’s with a face diameter of
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
No CRTs in the equipment.
N/A
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
Tested with additional 5.4kg
weights fixed to the equipment
weights fixed to the equipment
P
IEC 60950-1 (ed.1)
-
Page
5
of
5
-
www.nemko.com
Report No. 70512
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
TNV not provided.
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
TNV not provided.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
TNV not provided.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
TNV not provided.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
TNV not provided.
N/A
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.