IEC 60950-1 (ed.1) 
 - 
Page 
2
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
2.5 
Where a fuse is used to provide Class 2, Limited 
Power Source, or TNV current limiting, it shall not 
be operator-accessible unless it is not 
interchangeable. 
No such fuses. 
N/A 
2.7.1 
Suitable NEC/CEC branch circuit protection rated 
at the maximum circuit rating is required for all 
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch 
circuit protection is not suitable. 
Power distribution transformers distributing power 
at 100 V or more, and rated 10 kVA or more, 
require transformer overcurrent protection. 
No standard supply outlets, 
receptacles, lamp holders or 
such transformers. 
N/A 
3.2 
Wiring methods (terminals, leads etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC. 
Class III equipment.
 
N/A 
3.2.1 
Power supply cords are required to have 
attachment plugs rated not less than 125% of the 
rated current of the equipment. 
Class III equipment.
 
— 
3.2.3 
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs. 
Class III equipment. Not 
permanently connected to the 
mains. 
N/A 
3.2.5 
Power supply cords are required to be no longer 
than 4.5m in length. 
Flexible power supply cords are required to be 
compatible with Article 400 of the NEC, and 
Tables 11 and 12 of the CEC. 
Class III equipment.
 
N/A 
3.2.9 
Permanently connected equipment is required to 
have a suitable wiring compartment and wire 
bending space.
 
Class III equipment. Not 
permanently connected to the 
mains.
 
N/A 
3.3 
Wiring terminals and associated spacings for field 
wiring connections shall comply with CSA C22.2 
No. 0. 
Class III equipment.
 
N/A 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm
2
). 
Class III equipment.
 
N/A 
3.3.4 
Terminals for permanent wiring, including 
protective earthing terminals, are required to be 
suitable for U.S./Canadian wire gauge sizes, 
rated 125% of the equipment rating, and 
specially marked when specified (1.7.7).  
Class III equipment. Not 
permanently connected to the 
mains.
N/A 
3.4.2 
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12 A, or if the 
motor has a nominal voltage rating greater than 
120 V, or is rated more than 1/3 hp (locked rotor 
current over 43 A). 
No such motors in the 
equipment
N/A 
3.4.8 
Vertically-mounted disconnect switches and 
circuit breakers are required to have the “on” 
position indicated by the handle in the up 
position. 
No switch as disconnect device. 
N/A 
IEC 60950-1 (ed.1) 
 - 
Page 
3
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
3.4.11 
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit. 
No such battery in the 
equipment. 
N/A 
4.3.12 
The maximum quantity of flammable liquid stored 
in equipment is required to comply with NFPA 30.
No flammable liquids within the 
equipment. 
N/A 
4.3.13 
Equipment with lasers is required to meet the 
Code of Federal Regulations 21 CFR 1040 (and 
the Canadian Radiation Emitting Devices Act, 
REDR C1370). 
No lasers. LED’s are diffused 
type. 
N/A 
4.7 
For computer room applications, automated 
information storage systems with combustible 
media greater than 27 cubic feet are required to 
have a provision for connection of either 
automatic sprinklers or a gaseous agent 
extinguishing system with an extended 
discharge. 
The equipment has no 
combustible area greater than  
27 cubic feet. 
N/A 
4.7.3.1 
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 
m
2
 or a single dimension greater than 1.8 m are 
required to have a flame spread rating of 50 or 
less. For other applications, enclosures with the 
same dimensions require a flame spread rating 
of 200 or less. 
The equipment has no 
combustible material greater 
than 0.93m
2
 or single dimension 
greater than 1.8m. 
N/A 
Annex H  Equipment that produces ionizing radiation is 
required to comply with the Code of Federal 
Regulations, 21 CFR 1020 (and Canadian 
Radiation Emitting Devices Act, REDR C1370). 
The equipment does not produce 
ionizing radiation. 
N/A 
OTHER DIFFERENCES
 
The following key national differences are based on requirements other than national regulatory 
requirements. 
 
IEC 60950-1 (ed.1) 
 - 
Page 
4
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
1.5.1 
Some components and materials associated with 
the risk of fire, electric shock, or personal injury 
are required to have component or material 
ratings in accordance with the applicable national 
(U.S. and Canadian) component or material 
requirements.  
These components include:  
attachment plugs, battery packs (rechargeable 
type, used with transportable equipment), 
cathode ray tubes, circuit breakers, 
communication circuit accessories, connectors 
(used for current interruption of non-LPS circuits), 
cord sets and power supply cords, direct plug-in 
equipment, enclosures (outdoor), flexible cords 
and cables, fuses (branch circuit), fuseholders, 
ground-fault current interrupters, industrial control 
equipment, insulating tape, interconnecting 
cables, lampholders, limit controls, printed wiring, 
protectors for communications circuits, 
receptacles, solid state controls, supplementary 
protectors, surge suppressors, switches 
(including interlock switches), thermal cutoffs, 
thermostats, multi-layer transformer winding wire, 
tubing, wire connectors, and wire and cables  
All critical components are IEC, 
CSA, or UL certified. Refer to list 
of critical components in main 
CB report refer to appended 
table 1.5.1.  
2.3.1 
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 42.4 
Vp or 60 Vdc, the maximum acceptable current 
through a 2000 ohm resistor (or greater) 
connected across the voltage source with other 
loads disconnected is 7.1 mA peak or 30 mA dc 
under normal operating conditions. 
TNV not provided. 
N/A 
2.3.2 
In the event of a single fault, the limits of 2.2.3 
apply to SELV Circuits and accessible conductive 
parts. 
TNV not provided. 
N/A
 
2.6.3.4 
When subject to impedance testing, protective 
earthing and bonding are required to be 
subjected to the additional test conditions 
specified. 
Class III equipment. 
N/A 
3.2.1.2 
Equipment connected to centralized d.c. power 
system, and having one pole of the DC mains 
input terminal connected to the main protective 
earthing terminal in the equipment, is required to 
comply with special earthing, wiring, marking and 
installation instruction requirements. 
Class III equipment. Not for 
connection to DC mains. 
N/A 
4.2.8.1 
Enclosures around CRT’s with a face diameter of 
160 mm or more are required to reduce the risk 
of injury due to the implosion of the CRT. 
No CRTs in the equipment. 
N/A 
4.3.2 
Equipment with handles is required to comply 
with special loading tests. 
Tested with additional 5.4kg 
weights fixed to the equipment  
 
IEC 60950-1 (ed.1) 
 - 
Page 
5
 of 
5
 - 
 
 
www.nemko.com
 
Report No.   70512 
 
5.1.8.3 
Equipment intended to receive 
telecommunication ringing signals is required to 
comply with a special touch current 
measurement tests. 
TNV not provided. 
N/A 
6.2.1 
Enamel coating on winding wire not considered 
electrical separation unless subjected to special 
investigation. 
TNV not provided. 
N/A 
6.4 
Equipment intended for connection to 
telecommunication network outside plant cable is 
required to be protected against overvoltage from 
power line crosses in accordance with 6.4 and 
Annex NAC. 
TNV not provided. 
N/A 
6.5 
Equipment connected to a telecommunications 
network and supplied with an earphone intended 
to be held against, or in the ear is required to 
comply with special acoustic pressure tests. 
TNV not provided. 
N/A 
M.2 
Continuous ringing signals up to 16 mA only are 
permitted if the equipment is subjected to special 
installation and performance restrictions. 
TNV not provided. 
N/A 
 
Page of 127