Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online
- Page 24 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N/A
Part,
property,
retention after test, flammability
classification ........................................................ :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ..... :
N/A
4.3.13.5
Laser (including LEDs)
No laser components. LED is
diffused type.
diffused type.
N/A
Laser
class
.......................................................... :
—
4.3.13.6
Other types .......................................................... : No other parts of radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1 General
No
moving
parts.
N/A
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5 Thermal
requirements
P
4.5.1
Maximum temperatures
Refer to appended table 4.5.
P
Normal load condition per Annex L.....................: Refer to Test items particulars.
P
4.5.2
Resistance to abnormal heat
No thermoplastic parts carrying
hazardous voltages.
hazardous voltages.
N/A
4.6 Openings
in
enclosures
P
4.6.1
Top and side openings
Opening for speakers and the
sub port is covered by a metal
grid.
sub port is covered by a metal
grid.
P
Dimensions (mm) ...............................................: Metal grid: openings=0.8mm
—
4.6.2
Bottoms of fire enclosures
No bottom openings.
N/A
Construction of the bottom ..................................:
—
4.6.3
Doors or covers in fire enclosures
No doors or covers in fire
enclosure provided. (a tool is
required to open the battery
cover)
enclosure provided. (a tool is
required to open the battery
cover)
P
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by adhesive
inside enclosure.
inside enclosure.
N/A
Conditioning temperature (
°C)/time (weeks).......:
—
- Page 25 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.7 Resistance
to
fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Method 1 is used.
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
Fire enclosure provided, Refer
to appended table 1.5.1.
to appended table 1.5.1.
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Refer below:
P
4.7.2.1
Parts requiring a fire enclosure
The fire enclosure is required to
cover all parts.
cover all parts.
P
4.7.2.2
Parts not requiring a fire enclosure
The fire enclosure is required to
cover all parts.
cover all parts.
N/A
4.7.3 Materials
P
4.7.3.1 General
Components
and
materials
have adequate flammability
classification. Refer to
appended table 1.5.1.
classification. Refer to
appended table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
The fire enclosure is minimum
V-1 material. Refer to
appended table 1.5.1.
V-1 material. Refer to
appended table 1.5.1.
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
No parts outside fire enclosure.
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Other materials inside fire
enclosure are minimum V-2
material.
enclosure are minimum V-2
material.
P
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Class III equipment. Unit is not
intended for direct connection
to a mains supply. No test
considered necessary.
intended for direct connection
to a mains supply. No test
considered necessary.
N/A
5.1.2
Equipment under test (EUT)
Class III equipment.
N/A
5.1.3 Test
circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
N/A
- Page 26 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.1.6 Test
measurements
N/A
Test
voltage
(V)
................................................. :
—
Measured touch current (mA) ........................... :
—
Max. allowed touch current (mA) ...................... :
—
Measured protective conductor current (mA) ... :
—
Max. allowed protective conductor current (mA) :
—
5.1.7
Equipment with touch current exceeding 3.5 mA
............................................................................ :
............................................................................ :
N/A
5.1.8
Touch currents to telecommunication networks
and cable distribution systems and from
telecommunication networks
and cable distribution systems and from
telecommunication networks
No TNV or CDS.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
telecommunication network and a cable
distribution system
N/A
Test
voltage
(V)
................................................. :
—
Measured touch current (mA) ........................... :
—
Max. allowed touch current (mA) ...................... :
—
5.1.8.2
Summation of touch currents from
telecommunication networks.............................. :
telecommunication networks.............................. :
N/A
5.2 Electric
strength
N/A
5.2.1
General
Functional insulation, no test
required.
required.
N/A
5.2.2 Test
procedure
N/A
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
Refer to appended table 5.3.
P
5.3.2
Motors
There are no motors in the
equipment.
equipment.
N/A
5.3.3
Transformers
There are no safety
transformers in the equipment.
transformers in the equipment.
N/A
5.3.4
Functional insulation ...........................................: Complies with c), mounted on
V-1 or better material.
P
5.3.5 Electromechanical
components
No
electromechanical
components in secondary
circuits. (Speakers not
considered)
circuits. (Speakers not
considered)
N/A
- Page 27 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.3.6
Simulation of faults
Refer to appended table 5.3.
P
5.3.7 Unattended
equipment
No
thermostats,
temperature
limiters or thermal cut-outs
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire or molten metal
occurred and no deformation of
enclosure during the tests.
occurred and no deformation of
enclosure during the tests.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
No TNV circuits in the
equipment.
equipment.
N/A
Test
voltage
(V)
................................................. :
—
Current in the test circuit (mA) ......................... :
—
6.1.2.2 Exclusions .......................................................... :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1
Separation requirements
No TNV circuits in the
equipment.
equipment.
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1 Impulse
test
N/A
6.2.2.2 Steady-state
test
N/A
6.2.2.3 Compliance
criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) .......................................:
—
Current
limiting
method .......................................:
—
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
No CDS circuits in the
equipment.
equipment.
N/A
7.2
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.