Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online

 
 
- Page 24 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A 
 Part, 
property, 
retention after test, flammability 
classification ........................................................ :
 
N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation ..... :  
N/A 
4.3.13.5 
Laser (including LEDs) 
No laser components. LED is 
diffused type. 
N/A 
 Laser 
class 
.......................................................... :  
— 
4.3.13.6 
Other types .......................................................... : No other parts of radiation. 
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 General 
No 
moving 
parts. 
N/A 
4.4.2 
Protection in operator access areas 
 
N/A 
4.4.3 
Protection in restricted access locations  
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
 
4.5 Thermal 
requirements 
4.5.1 
Maximum temperatures 
Refer to appended table 4.5. 
 
Normal load condition per Annex L.....................:  Refer to Test items particulars. 
4.5.2 
Resistance to abnormal heat 
No thermoplastic parts carrying 
hazardous voltages. 
N/A 
 
4.6 Openings 
in 
enclosures 
4.6.1 
Top and side openings 
Opening for speakers and the 
sub port is covered by a metal 
grid. 
 
Dimensions (mm)  ...............................................:  Metal grid: openings=0.8mm 
— 
4.6.2 
Bottoms of fire enclosures 
No bottom openings. 
N/A 
 
Construction of the bottom ..................................:   
— 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers in fire 
enclosure provided. (a tool is 
required to open the battery 
cover) 
4.6.4 
Openings in transportable equipment 
The unit is not regarded as 
transportable equipment. 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by adhesive 
inside enclosure. 
N/A 
 
Conditioning temperature (
°C)/time (weeks).......:   
— 
 
 
- Page 25 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
4.7 Resistance 
to 
fire 
4.7.1 
Reducing the risk of ignition and spread of flame 
Method 1 is used. 
 
Method 1, selection and application of 
components wiring and materials 
Fire enclosure provided, Refer 
to appended table 1.5.1. 
 
Method 2, application of all of simulated fault 
condition tests 
 
N/A 
4.7.2 
Conditions for a fire enclosure 
Refer below: 
4.7.2.1 
Parts requiring a fire enclosure 
The fire enclosure is required to 
cover all parts. 
4.7.2.2 
Parts not requiring a fire enclosure 
The fire enclosure is required to 
cover all parts. 
N/A 
4.7.3 Materials 
4.7.3.1 General 
Components 
and 
materials 
have adequate flammability 
classification. Refer to 
appended table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
The fire enclosure is minimum 
V-1 material. Refer to 
appended table 1.5.1. 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
No parts outside fire enclosure.
N/A 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
Other materials inside fire 
enclosure are minimum V-2 
material. 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment. 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
N/A 
5.1.1 
General 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. No test 
considered necessary. 
N/A 
5.1.2 
Equipment under test (EUT) 
Class III equipment. 
N/A 
5.1.3 Test 
circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 Test 
procedure 
 
N/A 
 
 
- Page 26 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
5.1.6 Test 
measurements 
 
N/A 
 Test 
voltage 
(V) 
................................................. : 
 
— 
 
Measured touch current (mA)  ........................... :   
— 
 
Max. allowed touch current (mA)  ...................... :   
— 
 
Measured protective conductor current (mA)  ... :   
— 
 
Max. allowed protective conductor current (mA) :   
— 
5.1.7 
Equipment with touch current exceeding 3.5 mA   
............................................................................ : 
 
N/A 
5.1.8 
Touch currents to telecommunication networks 
and cable distribution systems and from 
telecommunication networks 
No TNV or CDS. 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network and a cable 
distribution system 
 
N/A 
 Test 
voltage 
(V) 
................................................. : 
 
— 
 
Measured touch current (mA)  ........................... :   
— 
 
Max. allowed touch current (mA)  ...................... :   
— 
5.1.8.2 
Summation of touch currents from 
telecommunication networks.............................. : 
 
N/A 
 
5.2 Electric 
strength 
N/A 
5.2.1 
General 
Functional insulation, no test 
required. 
N/A 
5.2.2 Test 
procedure 
 
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
P 
5.3.1 
Protection against overload and abnormal 
operation 
Refer to appended table 5.3. 
5.3.2 
Motors 
There are no motors in the 
equipment.  
N/A 
5.3.3 
Transformers 
There are no safety 
transformers in the equipment. 
N/A 
5.3.4 
Functional insulation ...........................................:  Complies with c), mounted on 
V-1 or better material. 
5.3.5 Electromechanical 
components 
No 
electromechanical 
components in secondary 
circuits. (Speakers not 
considered) 
N/A 
 
 
- Page 27 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
5.3.6 
Simulation of faults 
Refer to appended table 5.3. 
5.3.7 Unattended 
equipment 
No 
thermostats, 
temperature 
limiters or thermal cut-outs 
N/A 
5.3.8 
Compliance criteria for abnormal operating and 
fault conditions 
No fire or molten metal 
occurred and no deformation of 
enclosure during the tests. 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
No TNV circuits in the 
equipment. 
N/A 
 Test 
voltage 
(V) 
................................................. : 
 
— 
 
Current in the test circuit  (mA)  ......................... :   
— 
6.1.2.2 Exclusions .......................................................... : 
 
N/A 
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
N/A 
6.2.1 
Separation requirements 
No TNV circuits in the 
equipment. 
N/A 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 Impulse 
test 
 
N/A 
6.2.2.2 Steady-state 
test 
 
N/A 
6.2.2.3 Compliance 
criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
N/A 
 
Max. output current (A) .......................................:   
— 
 Current 
limiting 
method .......................................: 
 
— 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
N/A 
7.1 
Protection of cable distribution system service 
persons, and users of other equipment connected 
to the system, from hazardous voltages in the 
equipment 
No CDS circuits in the 
equipment. 
N/A 
7.2 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
N/A 