- Page 12 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
1.5.8 
Components in equipment for IT power systems 
Class III equipment. 
N/A 
 
1.6 Power 
interface 
1.6.1 
AC power distribution systems 
Class III equipment. 
N/A 
1.6.2 
Input current 
Refer to appended table 1.6.2.  
1.6.3 
Voltage limit of hand-held equipment 
The equipment is not hand-
held. 
N/A 
1.6.4 
Neutral conductor  
Class III equipment. 
N/A 
 
1.7 Markings 
and 
instructions 
1.7.1 
Power rating  
Marking not required, however 
the marking is located on the 
outside surface of the 
equipment. 
 
Rated voltage(s) or voltage range(s) (V)  ........... :  18Vdc 
 
Symbol for nature of supply, for d.c. only ........... :  IEC 60417-1, symbol No. 5031, 
is used. 
 
Rated frequency or rated frequency range (Hz)  :  DC rated. 
N/A 
 
Rated current (mA or A) ..................................... :  3.3A  
 
Manufacturer’s name or trademark or 
identification mark  .............................................. : 
 
 
Type/model or type reference ............................. :  Go+Play 
 
Symbol for Class II equipment only  ................... :  The equipment is Class III. 
N/A 
 
Other symbols  .................................................... :  The additional marking does 
not give rise to 
misunderstandings. 
 
Certification marks  ............................................. :  Refer to copy of markings. 
1.7.2 
Safety instructions 
Provided with marking 
regarding use of specified 
power supply (Not required), 
refer to Copy of marking plate. 
N/A 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment ................................. :  No voltage selector. 
N/A 
1.7.5 
Power outlets on the equipment  ........................ :  No standard power outlet. 
N/A 
1.7.6 Fuse 
identification 
.............................................. : 
No 
fuses. 
N/A 
1.7.7 
Wiring terminals 
Class III equipment. 
N/A 
 
 
- Page 13 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
1.7.7.1 
Protective earthing and bonding terminals  ........ :   
N/A 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
Refer below: 
1.7.8.1 
Identification, location and marking  ................... :  No controls or figures affecting 
safety provided. 
N/A 
1.7.8.2 
Colours ............................................................... :  No controls or indicators us 
color. 
N/A 
1.7.8.3 
Symbols   ............................................................ :  There are no switches in the 
equipment. Control is marked 
with “+” and “-“.  
1.7.8.4 
Markings using figures   ...................................... :  Refer to Copy of marking, the 
manufacturer includes 
explanation of graphic symbols 
in the instruction manual. 
1.7.9 
Isolation of multiple power sources .................... :  Class III equipment. 
N/A 
1.7.10 
IT power distribution systems  
Class III equipment. 
N/A 
1.7.11 
Thermostats and other regulating devices  
No thermostats or other 
regulating devices.  
N/A 
1.7.12 
Language  ........................................................... :  Instructions and markings shall 
be in a language acceptable for 
the country where the 
equipment is to be sold. 
English manual verified. 
— 
1.7.13 Durability 
The 
marking withstands 
required tests. 
1.7.14 
Removable parts 
No removable parts, except 
batteries. 
1.7.15 
Replaceable batteries 
Normal D-cell batteries to be 
used in the equipment.  
(See summary of testing). 
 Language ............................................................ : 
 
— 
1.7.16 
Operator access with a tool ................................ :  No hazardous voltages or 
energy levels in the equipment 
in normal or single fault 
condition.  
(See appended table 5.3) 
1.7.17 
Equipment for restricted access locations .......... :  Equipment not intended for 
installation in RAL.  
N/A 
 
 
 
- Page 14 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
PROTECTION FROM HAZARDS 
N/A 
2.1 
Protection from electric shock and energy hazards 
N/A 
2.1.1 
Protection in operator access areas  
Refer below: 
N/A 
2.1.1.1 
Access to energized parts 
Class III equipment. 
Output from the external PSU is 
considered to be below 240VA 
(Energy from batteries are 
below 240VA) 
(See appended table 2.1.1.5 
c1) 
N/A 
 
Test by inspection  ..............................................:   
N/A 
 
Test with test finger  ............................................:   
N/A 
 
Test with test pin  ................................................:   
N/A 
 
Test with test probe ............................................:   
N/A 
2.1.1.2 
Battery compartments ........................................:  No TNV circuits in the 
equipment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV. 
N/A 
 Working 
voltage 
(V); 
minimum distance (mm) 
through insulation 
 
— 
2.1.1.4 
Access to hazardous voltage circuit wiring 
Class III equipment. 
N/A 
2.1.1.5 
Energy hazards  ..................................................:  Class III equipment. 
The external SELV source is 
considered to be below 240VA 
(Energy from batteries are 
below 240VA) 
N/A 
2.1.1.6 
Manual controls 
No shafts or knobs. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
Class III equipment. 
N/A 
 
Time-constant (s); measured voltage (V) ...........:   
— 
2.1.2 
Protection in service access areas 
Class III equipment. 
N/A 
2.1.3 
Protection in restricted access locations 
Equipment not intended for 
installation in RAL. 
N/A 
 
2.2 SELV 
circuits 
2.2.1 
General requirements 
SELV limits are not exceeded 
under normal condition and 
after a single fault. Equipment 
is powered from a SELV 
source.  
 
 
- Page 15 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.2.2 
Voltages under normal conditions (V).................:  Powered by SELV source. 
2.2.3 
Voltages under fault conditions (V) .....................:  Powered by SELV source. 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
 
N/A 
2.2.3.2 
Separation by earthed screen (method 2) 
 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 
N/A 
2.2.4 
Connection of SELV circuits to other circuits....... : SELV circuits are only 
connected to other SELV 
circuits and protective earth. 
 
2.3 TNV 
circuits 
N/A 
2.3.1 Limits 
No 
TNV 
circuits. 
N/A 
 
Type of TNV circuits............................................:   
— 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
N/A 
 Insulation 
employed ............................................: 
 
— 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 Insulation 
employed ............................................: 
 
— 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 Insulation 
employed ............................................: 
 
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
2.4 Limited 
current 
circuits 
2.4.1 
General requirements 
Bridging capacitor (Y1) across 
insulation in the specified 
external power supply (See 
copy of marking plate). 
2.4.2 Limit 
values 
49mA, 
73.7nF 
 Frequency 
(Hz) ................................................... : 
70kHz 
— 
 
Measured current (mA) ....................................... :  1.8mA peak 
— 
 
Measured voltage (V).......................................... :  610Vp 
— 
 
Measured capacitance (
µF) ................................ :  3300pF 
— 
Page of 127