Harman Kardon ESQUIRE EMC - CB Certificate ▷ View online
Page 4 of 84 Report No. EFSN13070410E-1
TRF No. IEC60950_1C
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
the respective NCBs that own these marks.
(Additional requirements for markings. See 1.7 NOTE)
Label of adapter:
Label of speaker:
Page 5 of 84 Report No. EFSN13070410E-1
TRF No. IEC60950_1C
Page 6 of 84 Report No. EFSN13070410E-1
TRF No. IEC60950_1C
Test item particulars .................................................. :
Equipment mobility .................................................... : [] movable [] hand-held [X]transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................ : [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition ................................................... : [X] continuous
[] rated operating / resting time:
Access location ......................................................... : [X] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [] OVC I [X] OVC II [] OVC III [] OVC IV
[] other:
Mains supply tolerance (%) or absolute mains supply
values ....................................................................... :
values ....................................................................... :
±10%
Tested for IT power systems .................................... : [] Yes [X] No
IT testing, phase-phase voltage (V) ......................... :
Class of equipment ................................................... : [] Class I [] Class II [X] Class III
[] Not classified
Considered current rating of protective device as
part of the building installation (A) ............................ :
part of the building installation (A) ............................ :
Pollution degree (PD) ............................................... : [] PD 1 [X] PD 2 [] PD 3
IP protection class .................................................... : IP X0
Altitude during operation (m) .................................... : Up to 2000m
Altitude of test laboratory (m) ................................... : Below 2000m
Mass of equipment (kg) ............................................ : Approx.: 0.95Kg
Possible test case verdicts:
- test case does not apply to the test object................. : N/A
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ............................................ : 2013-07-03
Date(s) of performance of tests .................................... : 2013-07-03 to 2013-07-10
Page 7 of 84 Report No. EFSN13070410E-1
TRF No. IEC60950_1C
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Determination of the test result includes consideration of measurement uncertainty from the test
equipment and methods.
The related applicable CTL, OSM decisions have been considered and the requirements found
fulfilled
Throughout this report a
fulfilled
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : SHENZHEN FENDA TECHNOLOGY CO., LTD.
Building A,Fenda Hi-Tech Park, Zhoushi Road,
Shiyan, Baoan, Shenzhen,China 518108
Shiyan, Baoan, Shenzhen,China 518108
General product information:
The unit covered by this report is Portable wireless speaker with Bluetooth, used with information
technology equipment
The unit with two speaker, each speaker is 8ohm, 6W
The unit is Class III equipment, rated 5Vdc, 2.0A, supplied by lithium battery or approved external power
supply, lithium and adapter output comply with L.P.S
Electronic components mounted on PWB, housed with metal and plastic enclosure
Adapter rating: Input 100-240VAC, 50/60Hz, 0.8A; Output 5VDC, 5.0A (in total)
Abbreviations used in the report:
- normal conditions
N.C.
- single fault conditions
S.F.C
- functional insulation
OP
- basic insulation
BI
- double insulation
DI
- supplementary insulation SI
- between parts of opposite
- polarity
- polarity
BOP
- reinforced insulation
RI
Indicate used abbreviations (if any)