Harman Kardon ESQUIRE EMC - CB Certificate ▷ View online

 
Page 24 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
4.7.3.1 
General 
Components and materials 
have adequate flammability 
classification.  
See appended table 1.5.1 
4.7.3.2 
Materials for fire enclosures 
 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
HB plastic enclosure used 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
 
N/A 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
Evaluated in approved adapter 
N/A 
5.1.1 
General 
 
N/A 
5.1.2 
Configuration of equipment under test (EUT) 
 
N/A 
5.1.2.1 
Single connection to an a.c. mains supply 
 
N/A 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 
N/A 
5.1.2.3 
Simultaneous multiple connections to an a.c. 
mains supply 
 
N/A 
5.1.3 
Test circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 
Test procedure 
 
N/A 
5.1.6 
Test measurements 
 
N/A 
 
Supply voltage (V)  ................................................ :   
 
 
Measured touch current (mA)  .............................. :   
 
 
Max. allowed touch current (mA)  ......................... :   
 
 
Measured protective conductor current (mA)  ...... :   
 
 
Max. allowed protective conductor current (mA) .. :   
 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
N/A 
5.1.7.1 
General  ................................................................ :   
N/A 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
N/A 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
Not connected to a 
telecommunication network or 
cable distribution systems 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable 
distribution system 
 
N/A 
 
Page 25 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
 
Supply voltage (V)  ................................................ :   
 
 
Measured touch current (mA)  .............................. :   
 
 
Max. allowed touch current (mA)  ......................... :   
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks 
 
N/A 
 
a) EUT with earthed telecommunication ports  ..... :   
N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 
N/A 
 
5.2 
Electric strength 
Evaluated in approved apdater 
N/A 
5.2.1 
General 
 
N/A 
5.2.2 
Test procedure  
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
(see appended table 5.3) 
5.3.2 
Motors 
 
N/A 
5.3.3 
Transformers 
 
N/A 
5.3.4 
Functional insulation ............................................. :  Functional insulation complies 
with the requirements (c) 
5.3.5 
Electromechanical components 
The equipment does not have 
any electromechanical 
components  
N/A 
5.3.6 
Audio amplifiers in ITE  ......................................... :   
5.3.7 
Simulation of faults 
(see appended table 5.3) 
5.3.8 
Unattended equipment 
 
N/A 
5.3.9 
Compliance criteria for abnormal operating and 
fault conditions 
See below 
5.3.9.1 
During the tests 
No fire, emission of molten 
metal or deformation of 
enclosure was noted during 
the tests 
5.3.9.2 
After the tests 
Neither fire occurred nor 
molten metal emitted. No 
need to do electric strength 
test. 
 
 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
 
Page 26 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
(see appended table 5.2)  
N/A 
 
Supply voltage (V)  ................................................ : 
 
 
 
Current  in the test circuit  (mA)  ........................... : 
 
 
6.1.2.2 
Exclusions  ............................................................ : 
 
N/A 
 
6.2 
Protection of equipment users from overvoltages on telecommunication 
networks 
N/A 
6.2.1 
Separation requirements 
 
N/A 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 
Impulse test 
(see appended table 5.2)  
N/A 
6.2.2.2 
Steady-state test 
(see appended table 5.2)  
N/A 
6.2.2.3 
Compliance criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
N/A 
 
Max. output current (A)  ........................................ : 
 
 
 
Current limiting method  ........................................ : 
 
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
N/A 
7.1 
General 
Not connected to Cable 
Distribution System. 
N/A 
7.2 
Protection of cable distribution system service 
persons, and users of other equipment connected 
to the system, from hazardous voltages in the 
equipment 
 
N/A 
7.3 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
N/A 
7.4 
Insulation between primary circuits and cable 
distribution systems 
 
N/A 
7.4.1 
General 
 
N/A 
7.4.2 
Voltage surge test 
(see appended table 5.2) 
N/A 
7.4.3 
Impulse test 
(see appended table 5.2) 
N/A 
 
 
 
Page 27 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
N/A 
A.1 
Flammability test for fire enclosures of movable 
equipment having a total mass exceeding 18 kg, 
and of stationary equipment (see 4.7.3.2) 
 
N/A 
A.1.1 
Samples ................................................................ : 
 
 
 
Wall thickness (mm) .............................................. : 
 
 
A.1.2 
Conditioning of samples; temperature (
C)  .......... : 
 
N/A 
A.1.3 
Mounting of samples  ............................................ : 
 
N/A 
A.1.4 
Test flame (see IEC 60695-11-3) 
 
N/A 
 
Flame A, B, C or D  ............................................... : 
 
 
A.1.5 
Test procedure 
 
N/A 
A.1.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ..................................... : 
 
 
 
Sample 2 burning time (s) ..................................... : 
 
 
 
Sample 3 burning time (s) ..................................... : 
 
 
A.2 
Flammability test for fire enclosures of movable equipment having a total mass not 
exceeding 18 kg, and for material and components located inside fire enclosures 
(see 4.7.3.2 and 4.7.3.4) 
N/A 
A.2.1 
Samples, material ................................................. : 
 
 
 
Wall thickness (mm) .............................................. : 
 
 
A.2.2 
Conditioning of samples; temperature (°C)  .......... : 
 
N/A 
A.2.3 
Mounting of samples  ............................................ : 
 
N/A 
A.2.4 
Test flame (see IEC 60695-11-4) 
 
N/A 
 
Flame A, B or C  ................................................... : 
 
 
A.2.5 
Test procedure 
 
N/A 
A.2.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ..................................... : 
 
 
 
Sample 2 burning time (s) ..................................... : 
 
 
 
Sample 3 burning time (s) ..................................... : 
 
 
A.2.7 
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9   
N/A 
 
Sample 1 burning time (s) ..................................... : 
 
 
 
Sample 2 burning time (s) ..................................... : 
 
 
 
Sample 3 burning time (s) ..................................... : 
 
 
A.3 
Hot flaming oil test (see 4.6.2) 
 
N/A 
A.3.1 
Mounting of samples  
 
N/A 
A.3.2 
Test procedure  
 
N/A 
A.3.3 
Compliance criterion 
 
N/A 