EMC - CB Certificate
Brand
Device
Audio
File
esquire.pdf
Date

Harman Kardon ESQUIRE EMC - CB Certificate ▷ View online

 
Page 12 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.2 
SELV circuits 
2.2.1 
General requirements 
 
2.2.2 
Voltages under normal conditions (V)  ................... :  Between any conductor of the 
SELV circuits, 42.4Vpeak or 
60Vd.c. is not exceeded. 
2.2.3 
Voltages under fault conditions (V)  ....................... :  Under fault conditions 
voltages never exceed 71Vpk 
and 120Vdc and do not 
exceed 42.4Vpk or 60Vdc for 
more than 0.2 second 
2.2.4 
Connection of SELV circuits to other circuits  ...... : 
SELV circuits are only 
connected to other secondary 
circuits. SELV circuit and all 
interconnected circuits 
separated from primary by 
double/reinforced insulation 
 
2.3 
TNV circuits 
N/A 
2.3.1 
Limits 
No TNV circuits within the 
equipment. 
N/A 
 
Type of TNV circuits ............................................... :   
 
2.3.2 
Separation from other circuits and from accessible 
parts 
 
N/A 
2.3.2.1 
General requirements 
 
N/A 
2.3.2.2 
Protection by basic insulation 
 
N/A 
2.3.2.3 
Protection by earthing 
 
N/A 
2.3.2.4 
Protection by other constructions  ......................... :   
N/A 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 
Insulation employed ............................................... :   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 
Insulation employed ............................................... :   
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
 
 
 
2.4 
Limited current circuits 
N/A 
2.4.1 
General requirements 
 
N/A 
2.4.2 
Limit values 
 
N/A 
 
Frequency (Hz) ...................................................... :   
 
 
Measured current (mA) .......................................... :   
 
 
Measured voltage (V) ............................................. :   
 
 
Measured circuit capacitance (nF or µF) ............... :   
 
 
Page 13 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A 
 
2.5 
Limited power sources 
Also evaluated in approved adapter 
 
a) Inherently limited output 
 
N/A 
 
b) Impedance limited output 
 
N/A 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
 
d) Overcurrent protective device limited output 
 
N/A 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA) ..................................... : 
See table 2.5 
 
 
Current rating of overcurrent protective device (A) .:   
 
 
Use of integrated circuit (IC) current limiters 
 
 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
 
N/A 
2.6.2 
Functional earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ....................................................................... : 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ....................................................................... : 
 
 
 
Protective current rating (A), cross-sectional area 
(mm
2
), AWG ........................................................... : 
 
 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (
), voltage drop (V), test 
current (A), duration (min) ...................................... : 
 
N/A
 
2.6.3.5 
Colour of insulation ................................................ :   
N/A
 
2.6.4 
Terminals 
 
N/A
 
2.6.4.1 
General 
 
N/A
 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A
 
 
Rated current (A), type, nominal thread diameter 
(mm) ....................................................................... : 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
 
Page 14 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors and 
protective bonding conductors 
 
N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 
2.6.5.4 
Parts that can be removed by an operator 
 
N/A 
2.6.5.5 
Parts removed during servicing 
 
N/A 
2.6.5.6 
Corrosion resistance 
 
N/A 
2.6.5.7 
Screws for protective bonding 
 
N/A 
2.6.5.8 
Reliance on telecommunication network or cable 
distribution system 
 
N/A 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
N/A 
2.7.1 
Basic requirements 
 
N/A 
 
Instructions when protection relies on building 
installation 
 
N/A 
2.7.2 
Faults not simulated in 5.3.7 
 
— 
2.7.3 
Short-circuit backup protection 
 
N/A 
2.7.4 
Number and location of protective devices  ........... :   
N/A 
2.7.5 
Protection by several devices 
 
N/A 
2.7.6 
Warning to service personnel ................................ :   
N/A 
 
2.8 
Safety interlocks 
N/A 
2.8.1 
General principles 
No safety interlocks or similar 
devices within the equipment 
N/A 
2.8.2 
Protection requirements 
 
N/A 
2.8.3 
Inadvertent reactivation 
 
N/A 
2.8.4 
Fail-safe operation 
 
N/A 
 
Protection against extreme hazard 
 
N/A 
2.8.5 
Moving parts 
 
N/A 
2.8.6 
Overriding  
 
N/A 
2.8.7 
Switches, relays and their related circuits 
 
N/A 
2.8.7.1 
Separation distances for contact gaps and their 
related circuits (mm)  ............................................. : 
 
N/A 
2.8.7.2 
Overload test 
 
N/A 
2.8.7.3 
Endurance test 
 
N/A 
2.8.7.4 
Electric strength test  
 
N/A 
2.8.8 
Mechanical actuators 
 
N/A 
 
Page 15 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.9 
Electrical insulation 
2.9.1 
Properties of insulating materials 
Neither natural rubber, 
materials containing 
asbestons nor hygroscopic 
materials are used as 
insulation. No driving belts or 
coupling used. 
2.9.2 
Humidity conditioning 
 
N/A 
 
Relative humidity (%), temperature (°C)  ............... : 
 
 
2.9.3 
Grade of insulation 
Functional insulation 
considered, other insulation 
be evaluated in the approved 
adaptor 
2.9.4 
Separation from hazardous voltages 
 
N/A 
 
Method(s) used  ..................................................... :   
 
 
2.10 
Clearances, creepage distances and distances through insulation 
Class III device, no hazardous voltage inside; also evaluated in approved adapter 
2.10.1 
General  
See below.  
2.10.1.1 
Frequency  ............................................................. :   
N/A 
2.10.1.2 
Pollution degrees  .................................................. :  Pollution Degree 2. 
2.10.1.3 
Reduced values for functional insulation 
The functional insulation 
complied with clause 5.3.4 
2.10.1.4 
Intervening unconnected conductive parts 
 
N/A
 
2.10.1.5 
Insulation with varying dimensions 
 
N/A
 
2.10.1.6 
Special separation requirements 
 
N/A
 
2.10.1.7 
Insulation in circuits generating starting pulses 
 
N/A
 
2.10.2 
Determination of working voltage 
 
N/A
 
2.10.2.1 
General 
 
N/A
 
2.10.2.2 
RMS working voltage 
 
N/A
 
2.10.2.3 
Peak working voltage 
 
N/A
 
2.10.3 
Clearances 
 
2.10.3.1 
General 
 
2.10.3.2 
Mains transient voltages 
 
N/A 
 
a) AC mains supply  ............................................... :   
N/A 
 
b) Earthed d.c. mains supplies  ............................. :   
N/A 
 
c) Unearthed d.c. mains supplies  ......................... :   
N/A 
 
d) Battery operation  .............................................. :   
N/A 
2.10.3.3 
Clearances in primary circuits 
 
N/A 
Page of 85