Harman Kardon ESQUIRE EMC - CB Certificate ▷ View online

 
Page 8 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
GENERAL 
 
1.5 
Components 
1.5.1 
General 
See below 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended table 1.5.1). 
1.5.2 
Evaluation and testing of components 
Certified components are 
used in accordance with their 
ratings, certifications and they 
comply with applicable parts 
of this standard.  
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 60950-
1 and the relevant component 
standard.  
Components, for which no 
relevant IEC-standard exists, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950-1. 
1.5.3 
Thermal controls 
No thermal control. 
N/A 
1.5.4 
Transformers 
 
N/A 
1.5.5 
Interconnecting cables 
Interconnecting cables comply 
with the relevant requirements 
of this standard. 
1.5.6 
Capacitors bridging insulation 
Evaluated in approved 
adapter 
N/A 
1.5.7 
Resistors bridging insulation 
Evaluated in approved 
adapter 
N/A 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 
N/A 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 
N/A 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 
N/A 
1.5.8 
Components in equipment for IT power systems 
 
N/A 
1.5.9 
Surge suppressors 
Evaluated in approved 
adapter 
N/A 
1.5.9.1 
General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
 
Page 9 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
N/A 
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
Not directly connected to AC 
mains also evaluated in 
approved adapter 
N/A 
1.6.2 
Input current 
(see appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
This equipment is not 
handheld equipment 
N/A 
1.6.4 
Neutral conductor  
 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
The required marking is 
located on the outside surface 
of the equipment.
 
1.7.1.1 
Power rating marking 
See below 
 
Multiple mains supply connections.........................: 
 
N/A 
 
Rated voltage(s) or voltage range(s) (V)  .............. :  5Vdc 
 
Symbol for nature of supply, for d.c. only .............. :  The symbol is marked on the 
label 
 
Rated frequency or rated frequency range (Hz)  ... :  HARMAN KARDON 
ESQUIRE   
N/A 
 
Rated current (mA or A)  ........................................ :  2.0A 
1.7.1.2 
Identification markings 
See below 
 
Manufacturer’s name or trade-mark or 
identification mark  ................................................. : 
harman/kardon
 
 
Model identification or type reference  ................... : 
 
 
Symbol for Class II equipment only  ...................... :  Class III equipment 
N/A 
 
Other markings and symbols  ................................ :  Additional symbols or marking 
do not give rise to 
misunderstanding. 
1.7.2 
Safety instructions and marking 
English (Version in other 
language will be provided 
when submitted for national 
approval) 
1.7.2.1 
General 
 
1.7.2.2 
Disconnect devices 
Evaluated in approved 
adapter 
N/A 
1.7.2.3 
Overcurrent protective device 
 
N/A 
1.7.2.4 
IT power distribution systems 
 
N/A 
 
Page 10 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
1.7.2.5 
Operator access with a tool 
 
N/A 
1.7.2.6 
Ozone 
The equipment does not 
produce Ozone. 
N/A 
1.7.3 
Short duty cycles 
The equipment is designed for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment  ................................... :  No Voltage adjustment. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions  ......................................... : 
 
N/A 
1.7.5 
Power outlets on the equipment  .......................... :  No standard power outlet. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
 
N/A 
1.7.7 
Wiring terminals 
 
N/A 
1.7.7.1 
Protective earthing and bonding terminals  .......... :   
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors 
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
See below 
N/A 
1.7.8.1 
Identification, location and marking  ..................... :  No safety relevant indicators, 
switches and controls 
provided 
N/A 
1.7.8.2 
Colours   ................................................................ :   
N/A 
1.7.8.3 
Symbols according to IEC 60417......................... : 
 
N/A 
1.7.8.4 
Markings using figures   ....................................... : 
No figures used 
N/A 
1.7.9 
Isolation of multiple power sources  ..................... : 
 
N/A 
1.7.10 
Thermostats and other regulating devices  .......... : 
No thermostats or other 
regulating devices. 
N/A 
1.7.11 
Durability 
The marking plate was 
subjected to the permanence 
of marking test. The marking 
plate was rubbed with cloth 
soaked with water for 15s and 
then again for 15s with the 
cloth soaked with petroleum 
spirit. After this test there was 
no damage to the marking 
plate. The marking on the 
label did not fade. There was 
no curling of the marking 
plate. 
1.7.12 
Removable parts 
No removable parts provided 
N/A 
1.7.13 
Replaceable batteries  ......................................... : 
No replaceable batteries 
provided 
N/A 
 
Language(s)  ........................................................ : 
See above 
 
 
Page 11 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
1.7.14 
Equipment for restricted access locations ........... : 
The equipment is not intended 
to be use in restricted access 
locations. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
Supplied by approved adapter 
which provides SELV output 
only, and  no hazards live part 
in operator access areas. 
2.1.1.1 
Access to energized parts 
 
N/A 
 
Test by inspection  ................................................. :   
N/A 
 
Test with test finger (Figure 2A)  ............................ :   
N/A 
 
Test with test pin (Figure 2B)  ................................ :   
N/A 
 
Test with test probe (Figure 2C)  ........................... :  No TNV circuits within the 
equipment. 
N/A 
2.1.1.2 
Battery compartments  
TNV circuits within the 
equipment 
N/A 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV 
accessible to the operator. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No internal wiring at ELV 
accessible to the operator. 
N/A 
2.1.1.5 
Energy hazards  ..................................................... :   
N/A 
2.1.1.6 
Manual controls 
No conductive shafts of 
operating knobs, handles, 
levers and the like 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
 
N/A 
 
Measured voltage (V); time-constant (s) ................ :   
 
2.1.1.8 
Energy hazards 
– d.c. mains supply 
Not connected to DC mains 
supply. 
N/A 
 
a) Capacitor connected to the d.c. mains supply  .. :   
N/A 
 
b) Internal battery connected to the d.c. mains 
supply  .................................................................... : 
 
N/A 
2.1.1.9 
Audio amplifiers  ..................................................... :   
2.1.2 
Protection in service access areas 
No bare parts operating at 
hazardous voltage in a 
service access area 
N/A 
2.1.3 
Protection in restricted access locations 
The equipment is not limited 
to be used in restricted 
access locations. 
N/A 
 
 