Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 25 of 41 -
Order
No.
26088
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of
IEC 60 950
IEC 60 950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to
be changed accidentally
be changed accidentally
No voltage selector
N
14.9 Motors
N
14.9.1
Endurance test on motors
Only secondary DC low voltage fan in AMP module. No
special testing is considered necessary for this motor.
special testing is considered necessary for this motor.
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or
grease etc.
grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of
accumulation of flammable gases
accumulation of flammable gases
No battery
N
14.10.2
No possibility of recharging non-
rechargeable batteries
rechargeable batteries
N
14.10.3
Recharging currents and times
within manufacturers limits
within manufacturers limits
N
Lithium batteries discharge and
reverse currents within the
manufacturers limits
reverse currents within the
manufacturers limits
N
14.11 Optocouplers
P
Optocouplers comply with Cl. 8
Insulation thickness: > 0,4 mm
P
Internal and external dimensions to
13.1.1
13.1.1
Internal and external creepage and clearance distances
are > 4mm.
are > 4mm.
P
-
IEC 60065, 6th edition : 1998
-
- Page 26 of 41 -
Order
No.
26088
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet,
interconnection couplers and mains
socket-outlet meet the appropriate
standard
interconnection couplers and mains
socket-outlet meet the appropriate
standard
See list below.
P
Component Manufacturer Type Standard Certified
Remarks
sheet
by
(colour
etc.)
Appliance inlet
Zhangjiagang
Huajie Electronics
Huajie Electronics
SA-4S
IEC 60320-1
VDE
10A 250V~, black
Mains
socket outlet
Dae
Ryung
Electronic
A3-04-D007
IEC 60884-1
NEMKO
2.5A 250V~, black
Mains sockets and interconnection
couplers
couplers
The socket outlet on the Class II apparatus does only
permit connection of other Class II apparatus.
permit connection of other Class II apparatus.
P
Overload protection for
socket-outlets
socket-outlets
Socket-outlet fuse provided; F401, T2A L 250V
P
15.1.2
Connectors for antenna, earth,
audio, video or data:
audio, video or data:
P
No risk of insertion in mains
socket-outlets
socket-outlets
Only phono/RCA, Optical, Antenna and S-video terminal
used. Banana plug type speaker terminal also used, but
they are accepted due to below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
used. Banana plug type speaker terminal also used, but
they are accepted due to below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
P
Sockets for audio and video circuits
indicated with the symbol of 5.2.b.
indicated with the symbol of 5.2.b.
No sockets indicated with the symbol
N
15.1.3
Output terminals of AC adaptors or
similar devices not compatible with
household mains socket-outlets
similar devices not compatible with
household mains socket-outlets
N
15.2
Provision for protective earthing
Class II apparatus
N
Accessible conductive parts of
Class I equipment reliably
connected to earth terminal, within
equipment
Class I equipment reliably
connected to earth terminal, within
equipment
N
Switches or fuses in protective
earth circuits
earth circuits
N
Class I supply equipment with non-
hazardous live output voltage:
output circuit not connected to earth
hazardous live output voltage:
output circuit not connected to earth
N
Protective earth conductors correctly
coloured
coloured
N
-
IEC 60065, 6th edition : 1998
-
- Page 27 of 41 -
Order
No.
26088
Permanently connected apparatus
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
N
Protective earth connection of a part
removable by hand.
removable by hand.
N
Protective earth terminal resistant to
corrosion
corrosion
N
Earth resistance (
Ω) test: ≤ 0,1 Ω at
25 A
N
15.3
Terminals for external flexible cords
and for permanent connection to the
mains supply
and for permanent connection to the
mains supply
Appliance inlet applied
N
15.3.1
Adequate terminals for connection of
permanent wiring
permanent wiring
N
15.3.2
Reliable connection of non-
detachable cords:
detachable cords:
N
Connection of the non-detachable
cord
cord
N
Soldered to conductors of a printed
circuit board
circuit board
N
Adequate clearances and creepage
distances between connections
should a wire break away
distances between connections
should a wire break away
N
wire secured by additional means to
the conductor
the conductor
N
15.3.3
Screws and nuts clamping
conductors have adequate threads:
ISO 261, ISO 262 or similar
conductors have adequate threads:
ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped
around terminal prior to soldering or
held in place by additional means
around terminal prior to soldering or
held in place by additional means
N
Clamping of conductor and
insulation if not soldered or held by
screws
insulation if not soldered or held by
screws
N
15.3.5
Terminals allow connection of
appropriate cross-sectional area of
conductors, for the rated current of
the equipment
appropriate cross-sectional area of
conductors, for the rated current of
the equipment
N
15.3.6
Terminals to 15.3.3 have sizes
required by Table 8
required by Table 8
N
15.3.7
Terminals clamp conductors
between metal surfaces
between metal surfaces
N
-
IEC 60065, 6th edition : 1998
-
- Page 28 of 41 -
Order
No.
26088
Terminals designed to avoid
conductor slipping out when
tightened or loosened
conductor slipping out when
tightened or loosened
N
Terminals adequately fixed to avoid
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
N
15.3.8
Terminals carrying a current more
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
N
15.3.9
Termination of non-detachable
cords: wires terminated near to each
other
cords: wires terminated near to each
other
N
Terminals located and shielded: test
with 8 mm strand
with 8 mm strand
N
15.4
Devices forming a part of the mains
plug
plug
The apparatus is not a device forming a part of the
mains plug
mains plug
N
15.4.1
No undue strain on mains socket-
outlets
outlets
N
15.4.2
Device complies with standard for
dimensions of mains plugs
dimensions of mains plugs
N
15.4.3
Device has adequate mechanical
strength (tests a,b,c)
strength (tests a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
P
16.1
Mains cords sheathed type,
complying with IEC 60 227 for PVC
or IEC 60 245 for synthetic rubber
cords
complying with IEC 60 227 for PVC
or IEC 60 245 for synthetic rubber
cords
Appliance inlet, cord-set not supplied for testing.
See summary of testing.
See summary of testing.
N
Mains cord
Manufacturer
Marking
Cross-
Certified by
(type)
sectional
area
(mm2)
Non-detachable cords for Class I
have green/yellow core for
protective earth
have green/yellow core for
protective earth
Class II apparatus
N
16.2
Mains cords conductors have
adequate cross-sectional area for
rated current consumption of the
equipment
adequate cross-sectional area for
rated current consumption of the
equipment
N
Click on the first or last page to see other DPR 1005 (serv.man13) service manuals if exist.